FAGOR d11 — Dishwasher
[ACTIVE]Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Pressure switch chamber clogged d11; water column sensing membrane is sluggish or fails to return to zero.
On FAGOR dishwashers utilizing Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Heavy grease and food deposit coagulation inside the sump air bell chamber or kinked pressure tube.
Flush sump air trap with hot water and degreasing agent. Detach pressure switch hose and blow through to clear blockage. Press and hold the Start/Stop key for 5 seconds until the program indicator light clears and drain pump runs, then switch off.