Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Faure E25
FAQ TREEWhat does error code E25 mean on a Faure appliance?
Faure error code E25 indicates: Faure FWG / FWF Series / Magic'45 Compact Washer: AquaStop / auxiliary drain circuit anomaly E25; safety drain relay or secondary drain sensing mismatch..
What is the root cause of Faure error code E25?
The primary root cause for Faure code E25 is: On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Micro-switch contacts oxidized on base float sensor, auxiliary pump triac damaged, or logic mismatch in dual-drain system..
How do I fix or resolve Faure error code E25?
To resolve error code E25: Inspect bottom drip tray for water and test float switch continuity (< 1 Ω closed). Check auxiliary relay contacts on main PCB. Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.
Is it safe to clear Faure error code E25 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faure code E25 persists, the physical component causing On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Micro-switch contacts oxidized on base float sensor, auxiliary pump triac damaged, or logic mismatch in dual-drain system. must be inspected or replaced.
How do I test electrical resistance for Faure code E25 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..
What safety protocol must be followed before servicing Faure code E25?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?