OFFICIAL FAULT CODEE3
Faure
Faure // OFFICIAL DIAGNOSTIC BENCH

Faure E3

HobGeneral System & Mechanical Integration
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Hob
Other Brands Sharing Code E3:BoschE3SamsungE3LGE3WhirlpoolE3ElectroluxE3AEGE3BekoE3HaierE3CandyE3NeffE3

Symptom / Description

FAULT

Faure FIE / Induction Duo / Vitroceramic Cooktop: Mains over-voltage detected E3; supply line voltage exceeds safe operating ceiling (> 275V AC), tripping safety shutdown.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Faure (Faure FIE / Induction Duo / Vitroceramic Cooktop) models: Accidental 400V 2-phase connection due to lost or disconnected neutral wire in terminal connection block, or grid lightning power surge.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Immediately disconnect hob. Check junction box with multimeter across L1-N and L2-N (must read ~230V AC; if ~400V, fix floating neutral wire). Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Faure Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLGeneral System & Mechanical IntegrationHob / Cooktop
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
Earth Ground Continuity: <0.1Ω (Chassis metal to mains plug earth pin). Mains: 230V AC ±10%.NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Protective Earth Bonding & Incoming Mains Voltage
Test Pins & Connections
PROBE (+)
PROBE (-)
Between unpainted chassis metal and mains plug earth pin; incoming terminal block L-N
Tolerance & Diagnostic CriteriaProtective conductor impedance must remain <0.1Ω. Line voltage 207V–253V AC under load.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect electrical mains plug or trip dedicated circuit breaker before servicing.
  • !Wait at least 5 minutes before opening any casing panels to reset volatile microcontrollers and bleed residual charges.
  • !Operate in a dry workshop environment; never bypass internal electrical thermal cutouts.
3. Preliminary Mechanical & Visual Checks
  • Check appliance leveling with a spirit level; adjust threaded leveling feet for perfect stability.
  • Check door and lid perimeter rubber gaskets for tears, gaps, or foreign object obstruction.
  • Inspect shock absorbers, suspension springs, and rubber dampers for mechanical fatigue or excessive play.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Faure E3

FAQ TREE
What does error code E3 mean on a Faure appliance?

Faure error code E3 indicates: Faure FIE / Induction Duo / Vitroceramic Cooktop: Mains over-voltage detected E3; supply line voltage exceeds safe operating ceiling (> 275V AC), tripping safety shutdown..

What is the root cause of Faure error code E3?

The primary root cause for Faure code E3 is: On Faure (Faure FIE / Induction Duo / Vitroceramic Cooktop) models: Accidental 400V 2-phase connection due to lost or disconnected neutral wire in terminal connection block, or grid lightning power surge..

How do I fix or resolve Faure error code E3?

To resolve error code E3: Immediately disconnect hob. Check junction box with multimeter across L1-N and L2-N (must read ~230V AC; if ~400V, fix floating neutral wire). Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.

Is it safe to clear Faure error code E3 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faure code E3 persists, the physical component causing On Faure (Faure FIE / Induction Duo / Vitroceramic Cooktop) models: Accidental 400V 2-phase connection due to lost or disconnected neutral wire in terminal connection block, or grid lightning power surge. must be inspected or replaced.

How do I test electrical resistance for Faure code E3 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Protective Earth Bonding & Incoming Mains Voltage across Between unpainted chassis metal and mains plug earth pin; incoming terminal block L-N. Expected nominal reading is Earth Ground Continuity: <0.1Ω (Chassis metal to mains plug earth pin). Mains: 230V AC ±10%.. Tolerance: Protective conductor impedance must remain <0.1Ω. Line voltage 207V–253V AC under load..

What safety protocol must be followed before servicing Faure code E3?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // FAURE

Related Faure Hob / Cooktop Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E4General System & Mechanical Integration
Faure FIE / Induction Duo / Vitroceramic Cooktop: Mains under-voltage detected E4; electrica...
Inspect Protocol
E5NTC Temperature Sensor & Thermistor
Faure FIE / Induction Duo / Vitroceramic Cooktop: Induction power module heatsink over-tempe...
Inspect Protocol
E6Drive Motor, Inverter & Tachometer Sensor
Faure FIE / Induction Duo / Vitroceramic Cooktop: Induction power inverter IGBT short circui...
Inspect Protocol
E7Drive Motor, Inverter & Tachometer Sensor
Faure FIE / Induction Duo / Vitroceramic Cooktop: Hob cooling fan motor fault E7; internal 1...
Inspect Protocol
E8Electronic Control Board (PCB) & Bus Communications
Faure FIE / Induction Duo / Vitroceramic Cooktop: Power supply line communication missing E8...
Inspect Protocol
E9Door Lock Mechanism & Safety Interlock
Faure FIE / Induction Duo / Vitroceramic Cooktop: Touch control configuration error E9; inte...
Inspect Protocol
EANTC Temperature Sensor & Thermistor
Faure FIE / Induction Duo / Vitroceramic Cooktop: Induction coil temperature sensor circuit ...
Inspect Protocol
FDrive Motor, Inverter & Tachometer Sensor
Faure FIE / Induction Duo / Vitroceramic Cooktop: Pan detection symbol F flashing; cooking z...
Inspect Protocol
E0Electronic Control Board (PCB) & Bus Communications
Faure FIE / Induction Duo / Vitroceramic Cooktop: Electronic sub-bus communication error E0;...
Inspect Protocol
E1Water Level Pressure Switch & Air Dome
Faure FIE / Induction Duo / Vitroceramic Cooktop: Touch control surface blocked E1; continuo...
Inspect Protocol
E2NTC Temperature Sensor & Thermistor
Faure FIE / Induction Duo / Vitroceramic Cooktop: Induction coil overheating alarm E2; induc...
Inspect Protocol
F1Refrigeration Compressor, Defrost Heater & PTC Relay
Faure FRA / FRB Series / Defrost Control Fridge-Freezer: Fresh food compartment air sensor f...
Inspect Protocol
F2Refrigeration Compressor, Defrost Heater & PTC Relay
Faure FRA / FRB Series / Defrost Control Fridge-Freezer: Evaporator coil sensor failure F2; ...
Inspect Protocol
F3Refrigeration Compressor, Defrost Heater & PTC Relay
Faure FRA / FRB Series / Defrost Control Fridge-Freezer: Ambient room temperature sensor err...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy