OFFICIAL FAULT CODEE2
Faure
Faure // OFFICIAL DIAGNOSTIC BENCH

Faure E2

HobNTC Temperature Sensor & Thermistor
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Hob
Other Brands Sharing Code E2:BoschE2SiemensE2LGE2WhirlpoolE2ElectroluxE2AEGE2BekoE2HaierE2CandyE2NeffE2

Symptom / Description

FAULT

Faure FIE / Induction Duo / Vitroceramic Cooktop: Induction coil overheating alarm E2; induction zone temperature sensor exceeds allowable safety cutoff limit (> 240°C).

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Faure (Faure FIE / Induction Duo / Vitroceramic Cooktop) models: Empty pan boiled dry at maximum boost power, non-induction pan with thin base concentrating extreme heat, or degraded silicone heat-sink paste on coil NTC.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Switch off cooking zone and allow hob to cool down for 20 minutes. Inspect cookware suitability with a magnet. Verify coil NTC resistance (~100 kΩ at 25°C). Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Faure Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorHob / Cooktop
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Faure E2

FAQ TREE
What does error code E2 mean on a Faure appliance?

Faure error code E2 indicates: Faure FIE / Induction Duo / Vitroceramic Cooktop: Induction coil overheating alarm E2; induction zone temperature sensor exceeds allowable safety cutoff limit (> 240°C)..

What is the root cause of Faure error code E2?

The primary root cause for Faure code E2 is: On Faure (Faure FIE / Induction Duo / Vitroceramic Cooktop) models: Empty pan boiled dry at maximum boost power, non-induction pan with thin base concentrating extreme heat, or degraded silicone heat-sink paste on coil NTC..

How do I fix or resolve Faure error code E2?

To resolve error code E2: Switch off cooking zone and allow hob to cool down for 20 minutes. Inspect cookware suitability with a magnet. Verify coil NTC resistance (~100 kΩ at 25°C). Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.

Is it safe to clear Faure error code E2 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faure code E2 persists, the physical component causing On Faure (Faure FIE / Induction Duo / Vitroceramic Cooktop) models: Empty pan boiled dry at maximum boost power, non-induction pan with thin base concentrating extreme heat, or degraded silicone heat-sink paste on coil NTC. must be inspected or replaced.

How do I test electrical resistance for Faure code E2 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Faure code E2?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // FAURE

Related Faure Hob / Cooktop Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

E3General System & Mechanical Integration
Faure FIE / Induction Duo / Vitroceramic Cooktop: Mains over-voltage detected E3; supply lin...
Inspect Protocol
E4General System & Mechanical Integration
Faure FIE / Induction Duo / Vitroceramic Cooktop: Mains under-voltage detected E4; electrica...
Inspect Protocol
E5NTC Temperature Sensor & Thermistor
Faure FIE / Induction Duo / Vitroceramic Cooktop: Induction power module heatsink over-tempe...
Inspect Protocol
E6Drive Motor, Inverter & Tachometer Sensor
Faure FIE / Induction Duo / Vitroceramic Cooktop: Induction power inverter IGBT short circui...
Inspect Protocol
E7Drive Motor, Inverter & Tachometer Sensor
Faure FIE / Induction Duo / Vitroceramic Cooktop: Hob cooling fan motor fault E7; internal 1...
Inspect Protocol
E8Electronic Control Board (PCB) & Bus Communications
Faure FIE / Induction Duo / Vitroceramic Cooktop: Power supply line communication missing E8...
Inspect Protocol
E9Door Lock Mechanism & Safety Interlock
Faure FIE / Induction Duo / Vitroceramic Cooktop: Touch control configuration error E9; inte...
Inspect Protocol
EANTC Temperature Sensor & Thermistor
Faure FIE / Induction Duo / Vitroceramic Cooktop: Induction coil temperature sensor circuit ...
Inspect Protocol
FDrive Motor, Inverter & Tachometer Sensor
Faure FIE / Induction Duo / Vitroceramic Cooktop: Pan detection symbol F flashing; cooking z...
Inspect Protocol
E0Electronic Control Board (PCB) & Bus Communications
Faure FIE / Induction Duo / Vitroceramic Cooktop: Electronic sub-bus communication error E0;...
Inspect Protocol
E1Water Level Pressure Switch & Air Dome
Faure FIE / Induction Duo / Vitroceramic Cooktop: Touch control surface blocked E1; continuo...
Inspect Protocol
F1Refrigeration Compressor, Defrost Heater & PTC Relay
Faure FRA / FRB Series / Defrost Control Fridge-Freezer: Fresh food compartment air sensor f...
Inspect Protocol
F2Refrigeration Compressor, Defrost Heater & PTC Relay
Faure FRA / FRB Series / Defrost Control Fridge-Freezer: Evaporator coil sensor failure F2; ...
Inspect Protocol
F3Refrigeration Compressor, Defrost Heater & PTC Relay
Faure FRA / FRB Series / Defrost Control Fridge-Freezer: Ambient room temperature sensor err...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy