FAQ TREEWhat does error code AL01 mean on a Rosieres appliance?
Rosieres error code AL01 indicates: Refrigerator Compartment Sensor Fault.
What is the root cause of Rosieres error code AL01?
The primary root cause for Rosieres code AL01 is: The temperature sensor (NTC) for the fresh food compartment is faulty (open or short circuit)..
How do I fix or resolve Rosieres error code AL01?
To resolve error code AL01: The sensor, typically located behind a panel inside the fridge section, needs to be tested and replaced if faulty.
Is it safe to clear Rosieres error code AL01 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Rosieres code AL01 persists, the physical component causing The temperature sensor (NTC) for the fresh food compartment is faulty (open or short circuit). must be inspected or replaced.
How do I test electrical resistance for Rosieres code AL01 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..
What safety protocol must be followed before servicing Rosieres code AL01?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.