Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODEEr01
Rosieres
Rosieres // OFFICIAL DIAGNOSTIC BENCH

Rosieres Er01

OvenNTC Temperature Sensor & Thermistor
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Oven
Other Brands Sharing Code Er01:HaierER01CandyER01HooverER01BrandtER01De DietrichER01FAGORER01SauterER01AtlanticER-01GEER01IbernaER01

Symptom / Description

FAULT

Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Cavity temperature sensor open circuit Er01; electronic controller reads infinite resistance from the PT500 / PT1000 oven probe.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Rosières ovens utilizing French culinary precision thermal regulation, Paul Bocuse pyrolytic cavity, and GIAS Cuore microcomputer controller: Broken platinum resistor probe inside cavity, heat-damaged silicone wiring behind rear insulation, or loose PCB terminal.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Isolate power at breaker. Disconnect sensor plug at rear. Measure probe resistance (~538 Ω for PT500 or ~1078 Ω for PT1000 at 20°C). Replace if infinite. Return oven selectors to 0, switch off the kitchen circuit breaker for 60 seconds, re-engage and reset the rotary clock timer.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Rosieres Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLNTC Temperature Sensor & ThermistorOven / Microwave
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
4.8kΩ–12kΩ (at 20°C–25°C)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:NTC Temperature Sensor Probe (Thermistor)
Test Pins & Connections
PROBE (+)
PROBE (-)
Across sensor pins 1-2 (unplugged harness)
Tolerance & Diagnostic CriteriaNegative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V electrical mains power before removing appliance side or rear panels.
  • !Ensure tub water or heating chamber has cooled below 30°C before unclipping thermistor probe.
  • !Use CAT III 600V/1000V insulated test probes when tng at PCB edge connectors.
3. Preliminary Mechanical & Visual Checks
  • Inspect sensor immersion sleeve for calcification, limescale scale, or thermal paste degradation.
  • Check wiring harness for pinch points, chafing against chassis metal, and terminal pin oxidation.
  • Verify probe is firmly seated in its rubber grommet or bracket inside the water/air circuit.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Rosieres ER01

FAQ TREE
What does error code ER01 mean on a Rosieres appliance?

Rosieres error code ER01 indicates: Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Cavity temperature sensor open circuit Er01; electronic controller reads infinite resistance from the PT500 / PT1000 oven probe..

What is the root cause of Rosieres error code ER01?

The primary root cause for Rosieres code ER01 is: On Rosières ovens utilizing French culinary precision thermal regulation, Paul Bocuse pyrolytic cavity, and GIAS Cuore microcomputer controller: Broken platinum resistor probe inside cavity, heat-damaged silicone wiring behind rear insulation, or loose PCB terminal..

How do I fix or resolve Rosieres error code ER01?

To resolve error code ER01: Isolate power at breaker. Disconnect sensor plug at rear. Measure probe resistance (~538 Ω for PT500 or ~1078 Ω for PT1000 at 20°C). Replace if infinite. Return oven selectors to 0, switch off the kitchen circuit breaker for 60 seconds, re-engage and reset the rotary clock timer.

Is it safe to clear Rosieres error code ER01 by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Rosieres code ER01 persists, the physical component causing On Rosières ovens utilizing French culinary precision thermal regulation, Paul Bocuse pyrolytic cavity, and GIAS Cuore microcomputer controller: Broken platinum resistor probe inside cavity, heat-damaged silicone wiring behind rear insulation, or loose PCB terminal. must be inspected or replaced.

How do I test electrical resistance for Rosieres code ER01 using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test NTC Temperature Sensor Probe (Thermistor) across Across sensor pins 1-2 (unplugged harness). Expected nominal reading is 4.8kΩ–12kΩ (at 20°C–25°C). Tolerance: Negative temperature coefficient: resistance drops smoothly when warmed with fingers. OL = open circuit..

What safety protocol must be followed before servicing Rosieres code ER01?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // ROSIÈRES

Related Rosières Oven / Microwave Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

Er02NTC Temperature Sensor & Thermistor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Cavity temperature sensor short cir...
Inspect Protocol
Er03Heating Element, Thermostat & Safety Fuse
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Cavity overtemperature condition Er...
Inspect Protocol
Er04Drive Motor, Inverter & Tachometer Sensor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Tangential cooling fan failure Er04...
Inspect Protocol
Er05Drive Motor, Inverter & Tachometer Sensor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Pyrolysis door lock latch failure E...
Inspect Protocol
Er06Drive Motor, Inverter & Tachometer Sensor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Pyrolysis door unlock timeout Er06;...
Inspect Protocol
Er07NTC Temperature Sensor & Thermistor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Food meat probe circuit fault Er07;...
Inspect Protocol
Er08Heating Element, Thermostat & Safety Fuse
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Power relay board communication los...
Inspect Protocol
Er09Water Level Pressure Switch & Air Dome
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Stuck touch control key error Er09;...
Inspect Protocol
Er15NTC Temperature Sensor & Thermistor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Electronics housing ambient overtem...
Inspect Protocol
Er20Electronic Control Board (PCB) & Bus Communications
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Microcontroller flash memory checks...
Inspect Protocol
Er21Electronic Control Board (PCB) & Bus Communications
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Low-voltage DC power supply ripple ...
Inspect Protocol
Er22Electronic Control Board (PCB) & Bus Communications
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Touch control panel matrix evaluati...
Inspect Protocol
Er31Electronic Control Board (PCB) & Bus Communications
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Appliance variant model configurati...
Inspect Protocol
Er36NTC Temperature Sensor & Thermistor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Display console temperature sensor ...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy