Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODESabb
Rosieres
Rosieres // OFFICIAL DIAGNOSTIC BENCH

Rosieres Sabb

OvenGeneral System & Mechanical Integration
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Oven
Other Brands Sharing Code Sabb:HaierSABBCandySABBHooverSABBGESABBIbernaSABBZerowattSABB

Symptom / Description

FAULT

Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Sabbath mode operating status Sabb; steady-state heating enabled, display tones silenced, and door switches disabled.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Rosières ovens featuring French culinary precision thermal regulation, Paul Bocuse pyrolytic cavity, and GIAS Cuore microcomputer controller: Sabbath mode was intentionally or accidentally enabled through special key combination sequence.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1To exit Sabbath mode: Press and hold Clock/Timer and Bake keys together for 5 seconds until display reverts to standard clock, or power cycle breaker. Return oven selectors to 0, switch off the kitchen circuit breaker for 60 seconds, re-engage and reset the rotary clock timer.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Rosieres Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLGeneral System & Mechanical IntegrationOven / Microwave
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
Earth Ground Continuity: <0.1Ω (Chassis metal to mains plug earth pin). Mains: 230V AC ±10%.NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:Protective Earth Bonding & Incoming Mains Voltage
Test Pins & Connections
PROBE (+)
PROBE (-)
Between unpainted chassis metal and mains plug earth pin; incoming terminal block L-N
Tolerance & Diagnostic CriteriaProtective conductor impedance must remain <0.1Ω. Line voltage 207V–253V AC under load.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect electrical mains plug or trip dedicated circuit breaker before servicing.
  • !Wait at least 5 minutes before opening any casing panels to reset volatile microcontrollers and bleed residual charges.
  • !Operate in a dry workshop environment; never bypass internal electrical thermal cutouts.
3. Preliminary Mechanical & Visual Checks
  • Check appliance leveling with a spirit level; adjust threaded leveling feet for perfect stability.
  • Check door and lid perimeter rubber gaskets for tears, gaps, or foreign object obstruction.
  • Inspect shock absorbers, suspension springs, and rubber dampers for mechanical fatigue or excessive play.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Rosieres SABB

FAQ TREE
What does error code SABB mean on a Rosieres appliance?

Rosieres error code SABB indicates: Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Sabbath mode operating status Sabb; steady-state heating enabled, display tones silenced, and door switches disabled..

What is the root cause of Rosieres error code SABB?

The primary root cause for Rosieres code SABB is: On Rosières ovens featuring French culinary precision thermal regulation, Paul Bocuse pyrolytic cavity, and GIAS Cuore microcomputer controller: Sabbath mode was intentionally or accidentally enabled through special key combination sequence..

How do I fix or resolve Rosieres error code SABB?

To resolve error code SABB: To exit Sabbath mode: Press and hold Clock/Timer and Bake keys together for 5 seconds until display reverts to standard clock, or power cycle breaker. Return oven selectors to 0, switch off the kitchen circuit breaker for 60 seconds, re-engage and reset the rotary clock timer.

Is it safe to clear Rosieres error code SABB by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Rosieres code SABB persists, the physical component causing On Rosières ovens featuring French culinary precision thermal regulation, Paul Bocuse pyrolytic cavity, and GIAS Cuore microcomputer controller: Sabbath mode was intentionally or accidentally enabled through special key combination sequence. must be inspected or replaced.

How do I test electrical resistance for Rosieres code SABB using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test Protective Earth Bonding & Incoming Mains Voltage across Between unpainted chassis metal and mains plug earth pin; incoming terminal block L-N. Expected nominal reading is Earth Ground Continuity: <0.1Ω (Chassis metal to mains plug earth pin). Mains: 230V AC ±10%.. Tolerance: Protective conductor impedance must remain <0.1Ω. Line voltage 207V–253V AC under load..

What safety protocol must be followed before servicing Rosieres code SABB?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // ROSIÈRES

Related Rosières Oven / Microwave Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

STOPHeating Element, Thermostat & Safety Fuse
Overheat during Pyrolytic cycle. Diagnostic error code STOP reported by the internal system ...
Inspect Protocol
Er01NTC Temperature Sensor & Thermistor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Cavity temperature sensor open circ...
Inspect Protocol
Er02NTC Temperature Sensor & Thermistor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Cavity temperature sensor short cir...
Inspect Protocol
Er03Heating Element, Thermostat & Safety Fuse
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Cavity overtemperature condition Er...
Inspect Protocol
Er04Drive Motor, Inverter & Tachometer Sensor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Tangential cooling fan failure Er04...
Inspect Protocol
Er05Drive Motor, Inverter & Tachometer Sensor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Pyrolysis door lock latch failure E...
Inspect Protocol
Er06Drive Motor, Inverter & Tachometer Sensor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Pyrolysis door unlock timeout Er06;...
Inspect Protocol
Er07NTC Temperature Sensor & Thermistor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Food meat probe circuit fault Er07;...
Inspect Protocol
Er08Heating Element, Thermostat & Safety Fuse
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Power relay board communication los...
Inspect Protocol
Er09Water Level Pressure Switch & Air Dome
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Stuck touch control key error Er09;...
Inspect Protocol
Er15NTC Temperature Sensor & Thermistor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Electronics housing ambient overtem...
Inspect Protocol
Er20Electronic Control Board (PCB) & Bus Communications
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Microcontroller flash memory checks...
Inspect Protocol
Er21Electronic Control Board (PCB) & Bus Communications
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Low-voltage DC power supply ripple ...
Inspect Protocol
Er22Electronic Control Board (PCB) & Bus Communications
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Touch control panel matrix evaluati...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy