Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
Airlux • Central Diagnostic Dictionary
75 Verified Codes in Database

Airlux Error Codes & Diagnostics

Access our premium database of error codes, common faults, and professional repair solutions for Airlux appliances.

Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
CodeAppliancesFault / DiagnosticsRepair InstructionsAction
P7
Air Conditioner / Heat Pump
NTC Temperature Sensor & Thermistor

IPM sensor circuit malfunction

Defective NTC Temperature Sensor Probe (Thermistor), open/short circuit in the wiring harness, or faulty connector on the ntc temperature sensor & thermistor.

1. Disconnect 230V mains power. 2. Unplug NTC thermistor harness connector. 3. Measure NTC resistance with multimeter across pins 1-2 (nominal: 4.8kΩ–12kΩ at 20°C–25°C; resistance should drop smoothly when probe tip is warmed). Replace sensor if open circuit (OL). 4. Reset: Power cycle reset: Disconnect appliance from 230V mains for 3 minutes. Press and hold Start/Power for 10 seconds while unplugged, then reconnect power.

Diagnose
P8
Air Conditioner / Heat Pump
Drive Motor, Inverter & Tachometer Sensor

IPM high temperature protection

Defective 3-Phase Motor Windings / Tacho Generator / Carbon Brushes, open/short circuit in the wiring harness, or faulty connector on the drive motor, inverter & tachometer sensor.

Check outdoor fan, heat sink, and ensure normal airflow around inverter board.

Diagnose
Pc
Air Conditioner / Heat Pump
Electronic Control Board (PCB) & Bus Communications

Current detect circuit malfunction or Current sensor malfunction

Defective PCB Power Supply Rails & DC Bus Filter Capacitors, open/short circuit in the wiring harness, or faulty connector on the electronic control board (pcb) & bus communications.

1. Disconnect 230V mains power for 3 minutes. 2. Inspect wire harness and edge connectors on control board for loose pins or oxidation. 3. Inspect mechanical linkages and sensors associated with subsystem. 4. Reset: Power cycle reset: Disconnect appliance from 230V mains for 3 minutes. Press and hold Start/Power for 10 seconds while unplugged, then reconnect power.

Diagnose
PH
Air Conditioner / Heat Pump
Electronic Control Board (PCB) & Bus Communications

Over voltage protection for PN

Component fatigue, sensor feedback out of tolerance, wiring harness connector discontinuity, or electronic control board glitch.

Check incoming power supply voltage is not too high.

Diagnose
PL
Air Conditioner / Heat Pump
Electronic Control Board (PCB) & Bus Communications

Low PN voltage protection

Component fatigue, sensor feedback out of tolerance, wiring harness connector discontinuity, or electronic control board glitch.

1. Disconnect 230V mains power for 3 minutes. 2. Inspect wire harness and edge connectors on control board for loose pins or oxidation. 3. Inspect mechanical linkages and sensors associated with subsystem. 4. Reset: Power cycle reset: Disconnect appliance from 230V mains for 3 minutes. Press and hold Start/Power for 10 seconds while unplugged, then reconnect power.

Diagnose
PU
Air Conditioner / Heat Pump
Drive Motor, Inverter & Tachometer Sensor

Capacitor charge malfunction

Defective 3-Phase Motor Windings / Tacho Generator / Carbon Brushes, open/short circuit in the wiring harness, or faulty connector on the drive motor, inverter & tachometer sensor.

Check inverter board capacitor and charging circuit.

Diagnose
SAFE
Oven / Microwave
General System & Mechanical Integration

Oven controls are unresponsive, 'SAFE' is displayed

The child lock feature has been activated.

Consult the user manual to find the specific button combination to deactivate the child lock. It is typically a long press of a specific button or two buttons simultaneously.

Diagnose
U1
Air Conditioner / Heat Pump
Electronic Control Board (PCB) & Bus Communications

Compressor phase current detection circuit malfunction

Defective PCB Power Supply Rails & DC Bus Filter Capacitors, open/short circuit in the wiring harness, or faulty connector on the electronic control board (pcb) & bus communications.

Check current detection circuitry on PCB.

Diagnose
U2
Air Conditioner / Heat Pump
Electronic Control Board (PCB) & Bus Communications

Compressor protection against loss of phase

Component fatigue, sensor feedback out of tolerance, wiring harness connector discontinuity, or electronic control board glitch.

Check phase connections to the compressor.

Diagnose
U3
Air Conditioner / Heat Pump
Electronic Control Board (PCB) & Bus Communications

PN voltage drop protection

Component fatigue, sensor feedback out of tolerance, wiring harness connector discontinuity, or electronic control board glitch.

Check power supply for severe voltage drops.

Diagnose
U4
Air Conditioner / Heat Pump
Electronic Control Board (PCB) & Bus Communications

Compressor reverse protection

Component fatigue, sensor feedback out of tolerance, wiring harness connector discontinuity, or electronic control board glitch.

Check for correct phase sequence and wiring to the compressor.

Diagnose
U5
Air Conditioner / Heat Pump
Electronic Control Board (PCB) & Bus Communications

AC current detect circuit malfunction

Defective PCB Power Supply Rails & DC Bus Filter Capacitors, open/short circuit in the wiring harness, or faulty connector on the electronic control board (pcb) & bus communications.

Inspect current detection circuit on the main board.

Diagnose
U7
Air Conditioner / Heat Pump
Electronic Control Board (PCB) & Bus Communications

4-way valve reversal abnormal

Component fatigue, sensor feedback out of tolerance, wiring harness connector discontinuity, or electronic control board glitch.

Check reversing valve and coil for proper operation in heat cycle.

Diagnose
U8
Air Conditioner / Heat Pump
NTC Temperature Sensor & Thermistor

Disconnection of the exhaust temperature sensor

Defective NTC Temperature Sensor Probe (Thermistor), open/short circuit in the wiring harness, or faulty connector on the ntc temperature sensor & thermistor.

Reconnect or replace exhaust temperature sensor.

Diagnose
U9
Air Conditioner / Heat Pump
Electronic Control Board (PCB) & Bus Communications

AC power zero voltage detect error

Defective PCB Power Supply Rails & DC Bus Filter Capacitors, open/short circuit in the wiring harness, or faulty connector on the electronic control board (pcb) & bus communications.

Check power supply voltage quality and main PCB zero-cross detection circuit.

Diagnose
← Previous PagePage 3 of 3 (75 results)
Next Page →

Airlux — Complete Error Code Catalog

75 Verified Error Codes

Server-side index of all verified manufacturer error codes for technicians and automated crawlers.

Dishwasher5

AL01E7i10i20i30

Washing Machine8

E01E02E03E04E05E08E16E18

Oven / Microwave3

ER06ER10SAFE

Hob / Cooktop5

E3ER22FHL

Refrigerator / Freezer1

E9

Air Conditioner / Heat Pump53

b5b7C5E1E2E4E5E6E8EEEUF1F2F3F4F5F6F8F9FAFCFEFHH0H1H2H3H4H5H6H7HCHEL3LcLdLEP5P6P7P8PcPHPLPUU1U2U3U4U5U7U8U9
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy