Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Faure E24
FAQ TREEWhat does error code E24 mean on a Faure appliance?
Faure error code E24 indicates: Faure FWG / FWF Series / Magic'45 Compact Washer: Drain pump sensing feedback circuit error E24; microprocessor reads incorrect sensing voltage across pump line..
What is the root cause of Faure error code E24?
The primary root cause for Faure code E24 is: On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Drain pump disconnected or open circuit (infinite Ω), broken copper wire in harness, or defective sensing divider resistors on motherboard..
How do I fix or resolve Faure error code E24?
To resolve error code E24: Verify wiring continuity from main PCB connector J1 to drain pump terminals. Measure pump coil resistance (nominal 160–220 Ω). Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.
Is it safe to clear Faure error code E24 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faure code E24 persists, the physical component causing On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Drain pump disconnected or open circuit (infinite Ω), broken copper wire in harness, or defective sensing divider resistors on motherboard. must be inspected or replaced.
How do I test electrical resistance for Faure code E24 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Drain Pump Motor Stator Coils across Across pump motor spade terminals (L-N unclipped). Expected nominal reading is 160Ω–220Ω (Sync 230V) / 20Ω–45Ω (3-Phase BLDC). Tolerance: ±10% balance. Insulation resistance between coil and motor chassis must exceed 20MΩ..
What safety protocol must be followed before servicing Faure code E24?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?