Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
OEM VERIFIED BENCH
OFFICIAL FAULT CODELoc
Rosieres
Rosieres // OFFICIAL DIAGNOSTIC BENCH

Rosieres Loc

OvenDoor Lock Mechanism & Safety Interlock
Integrated luxury convection oven and induction cooktop with illuminated touch controls
Oven
Other Brands Sharing Code Loc:HaierLOCCandyLOCHooverLOCGELOCIbernaLOCZerowattLOC

Symptom / Description

FAULT

Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Child safety lock active Loc; control panel keypad inputs are locked to prevent accidental burner/oven activation.

TELEMETRY // LIVESIG: FAULT_DETECTED

Root Cause

ROOT CAUSE

On Rosières ovens utilizing French culinary precision thermal regulation, Paul Bocuse pyrolytic cavity, and GIAS Cuore microcomputer controller: Key lock feature engaged by user holding the Keypad Lock or Clear/Off pad for 3 to 5 seconds.

CIRCUIT // SUBSYSTEMLOGIC: ROOT_ISOLATED

Repair Instructions

UNLOCKED
1Press and hold the Key Lock / Padlock icon pad continuously for 3 to 5 seconds until confirmation beep sounds and 'Loc' message disappears. Return oven selectors to 0, switch off the kitchen circuit breaker for 60 seconds, re-engage and reset the rotary clock timer.
AI diagnostic workshop engine analyzing appliance circuit schematics and error telemetry in real time
AI WORKSHOP PROTOCOL ENGINE
Direct extraction from OEM factory manuals & wiring schematics

Field Actions

DISPATCH
Need Help? Call a Certified TechnicianWorldwide Rosieres Parts Finder
Electrical & Safety Protocol

Always disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.

CALIBRATED BENCH PROTOCOL // CAT III 600V

Workshop Verification & Safety Checklist

WORKSHOP VERIFICATION PROTOCOLDoor Lock Mechanism & Safety InterlockOven / Microwave
2. Multimeter & Electrical Bench Tests (Ω)
MODE: OHMMETER (Ω)AUTO-RANGE
Precision digital multimeter probes measuring electrical resistance in Ohms on an appliance control board
CALIBRATED METROLOGY RESISTANCE BENCH (CAT III)
Nominal Resistance (Ω)
800Ω–1.5kΩ (PTC terminals L-N) / 60Ω–120Ω (Pulse Solenoid)NOMINAL
0 Ω (SHORT)CALIBRATED BAND∞ OL (OPEN)
▲ NOMINAL OPERATING WINDOW
Target Component:PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Test Pins & Connections
PROBE (+)
PROBE (-)
Across PTC heater terminals on lock bezel; switch contact reads <0.2Ω when locked
Tolerance & Diagnostic Criteria±15%. Switch contacts must read open (OL) when unlocked and 0.0Ω–0.2Ω when fully latched.
1. Pre-Intervention Electrical Safety Protocols
  • !Electrical Safety Protocol: Disconnect 230V mains power before releasing door gasket clamp or lock retaining screws.
  • !Never short-circuit or bypass the safety door lock contacts: severe hazard of rotating drum exposure or fire.
  • !Keep fingers away from spring-loaded latch mechanisms during closure cycling.
3. Preliminary Mechanical & Visual Checks
  • Inspect door strike pin and handle latch hook for plastic deformation, breakage, or misalignment.
  • Check door hinge alignment: a sagging door prevents the latch tongue from engaging the safety microswitch.
  • Locate and verify emergency manual pull cord inside the lower drain pump hatch.
Perform these diagnostic steps before triggering AI Deep Search or replacing boards.Certified Workshop Routine

Frequently Asked Questions: Rosieres LOC

FAQ TREE
What does error code LOC mean on a Rosieres appliance?

Rosieres error code LOC indicates: Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Child safety lock active Loc; control panel keypad inputs are locked to prevent accidental burner/oven activation..

What is the root cause of Rosieres error code LOC?

The primary root cause for Rosieres code LOC is: On Rosières ovens utilizing French culinary precision thermal regulation, Paul Bocuse pyrolytic cavity, and GIAS Cuore microcomputer controller: Key lock feature engaged by user holding the Keypad Lock or Clear/Off pad for 3 to 5 seconds..

How do I fix or resolve Rosieres error code LOC?

To resolve error code LOC: Press and hold the Key Lock / Padlock icon pad continuously for 3 to 5 seconds until confirmation beep sounds and 'Loc' message disappears. Return oven selectors to 0, switch off the kitchen circuit breaker for 60 seconds, re-engage and reset the rotary clock timer.

Is it safe to clear Rosieres error code LOC by resetting power?

Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Rosieres code LOC persists, the physical component causing On Rosières ovens utilizing French culinary precision thermal regulation, Paul Bocuse pyrolytic cavity, and GIAS Cuore microcomputer controller: Key lock feature engaged by user holding the Keypad Lock or Clear/Off pad for 3 to 5 seconds. must be inspected or replaced.

How do I test electrical resistance for Rosieres code LOC using a multimeter?

Set a digital multimeter to ohms (Ω). Disconnect power and test PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts across Across PTC heater terminals on lock bezel; switch contact reads <0.2Ω when locked. Expected nominal reading is 800Ω–1.5kΩ (PTC terminals L-N) / 60Ω–120Ω (Pulse Solenoid). Tolerance: ±15%. Switch contacts must read open (OL) when unlocked and 0.0Ω–0.2Ω when fully latched..

What safety protocol must be followed before servicing Rosieres code LOC?

Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.

Community Verification

COMMUNITY

Did this solution resolve the issue?

SEMANTIC KNOWLEDGE GRAPH // ROSIÈRES

Related Rosières Oven / Microwave Error Codes

Diagnostic Link Mesh14 OEM Cross-References

Cross-referenced diagnostic codes for technicians inspecting similar component subsystems.

SabbGeneral System & Mechanical Integration
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Sabbath mode operating status Sabb;...
Inspect Protocol
STOPHeating Element, Thermostat & Safety Fuse
Overheat during Pyrolytic cycle. Diagnostic error code STOP reported by the internal system ...
Inspect Protocol
Er01NTC Temperature Sensor & Thermistor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Cavity temperature sensor open circ...
Inspect Protocol
Er02NTC Temperature Sensor & Thermistor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Cavity temperature sensor short cir...
Inspect Protocol
Er03Heating Element, Thermostat & Safety Fuse
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Cavity overtemperature condition Er...
Inspect Protocol
Er04Drive Motor, Inverter & Tachometer Sensor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Tangential cooling fan failure Er04...
Inspect Protocol
Er05Drive Motor, Inverter & Tachometer Sensor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Pyrolysis door lock latch failure E...
Inspect Protocol
Er06Drive Motor, Inverter & Tachometer Sensor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Pyrolysis door unlock timeout Er06;...
Inspect Protocol
Er07NTC Temperature Sensor & Thermistor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Food meat probe circuit fault Er07;...
Inspect Protocol
Er08Heating Element, Thermostat & Safety Fuse
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Power relay board communication los...
Inspect Protocol
Er09Water Level Pressure Switch & Air Dome
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Stuck touch control key error Er09;...
Inspect Protocol
Er15NTC Temperature Sensor & Thermistor
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Electronics housing ambient overtem...
Inspect Protocol
Er20Electronic Control Board (PCB) & Bus Communications
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Microcontroller flash memory checks...
Inspect Protocol
Er21Electronic Control Board (PCB) & Bus Communications
Rosières Sublime / Origine / Paul Bocuse Pyrolytic Oven: Low-voltage DC power supply ripple ...
Inspect Protocol
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy