Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Faure E11
FAQ TREEWhat does error code E11 mean on a Faure appliance?
Faure error code E11 indicates: Faure FWG / FWF Series / Magic'45 Compact Washer: Fill timeout during wash phase E11; water level drops below electronic pressure sensor threshold while tumbling..
What is the root cause of Faure error code E11?
The primary root cause for Faure code E11 is: On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Siphoning down the drain pipe (drain hose inserted too deep into standpipe < 60 cm height), partial water supply restriction, or leaky pressure switch chamber hose..
How do I fix or resolve Faure error code E11?
To resolve error code E11: Check drain hose height (must be between 65 cm and 100 cm with air anti-siphon gap). Inspect pressure transducer tubing for perforations or moisture. Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.
Is it safe to clear Faure error code E11 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faure code E11 persists, the physical component causing On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Siphoning down the drain pipe (drain hose inserted too deep into standpipe < 60 cm height), partial water supply restriction, or leaky pressure switch chamber hose. must be inspected or replaced.
How do I test electrical resistance for Faure code E11 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Mechanical Pressure Switch Contacts / Inductive Frequency Sensor across Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal. Expected nominal reading is Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.. Tolerance: Mechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%..
What safety protocol must be followed before servicing Faure code E11?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?



