Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Faure E12
FAQ TREEWhat does error code E12 mean on a Faure appliance?
Faure error code E12 indicates: Faure FWG / FWF Series / Magic'45 Compact Washer: Condenser water fill error E12 on washer-dryer; cold water injection for condensation fails during dry cycle..
What is the root cause of Faure error code E12?
The primary root cause for Faure code E12 is: On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Secondary solenoid valve for drying condenser open-circuit (expected 3.8–4.4 kΩ), lime buildup in condenser nozzle, or dedicated triac failure on main PCB..
How do I fix or resolve Faure error code E12?
To resolve error code E12: Measure resistance across the drying condenser solenoid valve coil (expected ~4 kΩ). Clean nozzle orifice in rear air duct. Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.
Is it safe to clear Faure error code E12 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faure code E12 persists, the physical component causing On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Secondary solenoid valve for drying condenser open-circuit (expected 3.8–4.4 kΩ), lime buildup in condenser nozzle, or dedicated triac failure on main PCB. must be inspected or replaced.
How do I test electrical resistance for Faure code E12 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Solenoid Valve Coil / Aquastop Pneumatic Valve across Across coil spade terminals (disconnect harness first). Expected nominal reading is 3.5kΩ–4.5kΩ (Standard 230V) / 2.0kΩ–4.2kΩ (Aquastop). Tolerance: ±10%. Open circuit (OL) indicates burned solenoid coil. Flowmeter turbine reed switch pulses on flow..
What safety protocol must be followed before servicing Faure code E12?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?