Field Actions
DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Faure C9
FAQ TREEWhat does error code C9 mean on a Faure appliance?
Faure error code C9 indicates: Faure FWG / FWF Series / Magic'45 Compact Washer: Motor speed control alarm C9 (legacy alphanumeric); motor fails to rotate or tachometer signal is missing..
What is the root cause of Faure error code C9?
The primary root cause for Faure code C9 is: On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Worn carbon brushes (< 12 mm length), motor thermal protector tripped, detached tachometer magnet, or burnt motor drive triac..
How do I fix or resolve Faure error code C9?
To resolve error code C9: Check carbon brush length (replace if < 12 mm). Measure tachometer coil (130–220 Ω) and reset C9 by turning selector from off to 95°C cottons while holding Start and Option. Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.
Is it safe to clear Faure error code C9 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faure code C9 persists, the physical component causing On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Worn carbon brushes (< 12 mm length), motor thermal protector tripped, detached tachometer magnet, or burnt motor drive triac. must be inspected or replaced.
How do I test electrical resistance for Faure code C9 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Immersion / Air Heating Element & Klixon Thermostat across Between element terminals (unwired). Insulation to earth casing: >20MΩ (OL). Expected nominal reading is 25Ω–28Ω (230V / 2000W) / <0.5Ω (Safety Klixon closed). Tolerance: Formula R = V²/P (±5%). Any earth leakage reading below 2MΩ will trip the domestic 30mA RCD breaker..
What safety protocol must be followed before servicing Faure code C9?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.
Community Verification
COMMUNITYDid this solution resolve the issue?