DISPATCHAlways disconnect appliance from 230V/400V mains before opening panels. Use CAT III multimeter for circuit testing.
Frequently Asked Questions: Faure E10
FAQ TREEWhat does error code E10 mean on a Faure appliance?
Faure error code E10 indicates: Faure FWG / FWF Series / Magic'45 Compact Washer: Water fill timeout alarm E10; appliance fails to reach minimum static wash water level within 5 minutes..
What is the root cause of Faure error code E10?
The primary root cause for Faure code E10 is: On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Inlet water tap closed, kinked inlet hose, clogged solenoid valve filter screen, defective 230V solenoid valve coil (expected 3.5–4.5 kΩ), or open triac on EWM motherboard..
How do I fix or resolve Faure error code E10?
To resolve error code E10: Verify household water pressure (min 1 bar). Unscrew inlet hose and clean mesh filter. Measure solenoid valve coil resistance with multimeter (3.5–4.5 kΩ). Press and hold Départ/Pause and Annulation buttons for 6 seconds until all status indicators flash synchronously and clear fault memory.
Is it safe to clear Faure error code E10 by resetting power?
Resetting power (unplugging for 5–10 minutes) clears temporary memory errors. However, if Faure code E10 persists, the physical component causing On Faure (Faure FWG / FWF Series / Magic'45 Compact Washer) models: Inlet water tap closed, kinked inlet hose, clogged solenoid valve filter screen, defective 230V solenoid valve coil (expected 3.5–4.5 kΩ), or open triac on EWM motherboard. must be inspected or replaced.
How do I test electrical resistance for Faure code E10 using a multimeter?
Set a digital multimeter to ohms (Ω). Disconnect power and test Mechanical Pressure Switch Contacts / Inductive Frequency Sensor across Across switch spade contacts with harness unplugged; electronic output: 40Hz–50Hz frequency signal. Expected nominal reading is Mechanical: Continuity 0.0Ω–0.2Ω (Empty: 11-12, Full: 11-14). Electronic: 20Ω–45Ω coil resistance.. Tolerance: Mechanical switch contacts must transition cleanly on gentle breath pressure. Coil ~22Ω ±5%..
What safety protocol must be followed before servicing Faure code E10?
Standard electrical safety protocol: 1. Disconnect 230V mains power before opening panels. 2. Verify zero voltage at test points. 3. Allow hot water or heating elements to cool below 30°C before handling.