Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
Electrolux • Central Diagnostic Dictionary
191 Verified Codes in Database

Electrolux Error Codes & Diagnostics

Access our premium database of error codes, common faults, and professional repair solutions for Electrolux appliances.

Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
CodeAppliancesFault / DiagnosticsRepair InstructionsAction
AL5
Dishwasher
Water Level Pressure Switch & Air Dome

Electrolux RealLife / Intuit / QuickSelect Dishwasher: Water fill failure AL5 (legacy EDW1500 alphanumeric); inlet valve open but required water level not reached.

On Electrolux (Electrolux RealLife / Intuit / QuickSelect Dishwasher) models: Closed supply tap, blocked inlet filter, defective 230V solenoid valve coil (nominal 3.8–4.4 kΩ), or airlock in water softener matrix.

Verify tap water pressure. Clean mesh filter in inlet fitting. Measure solenoid coil resistance (expected 3.8–4.4 kΩ). Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
AL6
Dishwasher
Heating Element, Thermostat & Safety Fuse

Electrolux RealLife / Intuit / QuickSelect Dishwasher: Water heating failure AL6 (legacy EDW1500 alphanumeric); wash temperature fails to rise.

On Electrolux (Electrolux RealLife / Intuit / QuickSelect Dishwasher) models: Open heating element (nominal 25–28 Ω), tripped Klixon safety thermostat on heater casing, or open heating relay contact on PCB.

Measure resistance across heating element terminals (25–28 Ω). Check continuity of safety Klixon (< 1 Ω). Resolder relay contacts on PCB. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
C1
Dishwasher
Water Level Pressure Switch & Air Dome

Electrolux RealLife / Intuit / QuickSelect Dishwasher: Water inlet timeout alarm C1 (legacy DIVA alphanumeric); filling duration exceeds maximum safety limit.

On Electrolux (Electrolux RealLife / Intuit / QuickSelect Dishwasher) models: Closed water tap, kinked inlet hose, clogged valve filter screen, defective 230V solenoid valve coil (3.8–4.4 kΩ), or air trap restriction.

Open household water tap. Unscrew inlet connection and clean mesh strainer under running water. Measure valve resistance (3.8–4.4 kΩ). Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
C2
Dishwasher
Drainage System & Drain Pump

Electrolux RealLife / Intuit / QuickSelect Dishwasher: Water drainage timeout alarm C2 (legacy DIVA alphanumeric); tub fails to drain water before next cycle step.

On Electrolux (Electrolux RealLife / Intuit / QuickSelect Dishwasher) models: Drain filter clogged by food residue, pump impeller jammed with broken glass, kinked drain hose, or drain pump motor open (160–220 Ω).

Remove sump filter assembly and clean thoroughly. Check that pump impeller rotates freely. Measure pump resistance (160–220 Ω). Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
C3
Dishwasher
Drainage System & Drain Pump

Electrolux RealLife / Intuit / QuickSelect Dishwasher: AquaControl flood protection active C3 (legacy DIVA alphanumeric); base float switch raised, continuous drain.

On Electrolux (Electrolux RealLife / Intuit / QuickSelect Dishwasher) models: Internal water leakage into bottom tray, loose hose clamp on sump or circulation pump, split tub bellow, or leaking dispenser gasket.

Unplug dishwasher and shut water tap. Mop up all water from bottom drip tray. Inspect hoses under pressure to locate and repair leak. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
C9
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

Electrolux PerfectCare 600/700/800 UltraCare Washer: Motor speed control alarm C9 (legacy alphanumeric); motor fails to rotate or tachometer signal is missing.

On Electrolux (Electrolux PerfectCare 600/700/800 UltraCare Washer) models: Worn carbon brushes (< 12 mm length), motor thermal protector tripped, detached tachometer magnet, or burnt motor drive triac.

Check carbon brush length (replace if < 12 mm). Measure tachometer coil (130–220 Ω) and reset C9 by turning selector from off to 95°C cottons while holding Start and Option. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
CF
Washing Machine
Electronic Control Board (PCB) & Bus Communications

Electrolux PerfectCare 600/700/800 UltraCare Washer: Configuration checksum error in EEPROM CF (legacy alphanumeric); board parameters invalid.

On Electrolux (Electrolux PerfectCare 600/700/800 UltraCare Washer) models: Microprocessor detected corrupted configuration table in non-volatile memory or new unprogrammed replacement board installed.

Reprogram 16-character hexadecimal configuration code in service mode. If memory fails to write and retain code, replace main control board. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E0
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Electrolux Infinite / Bridge / SenseBoil Induction Hob: Electronic sub-bus communication error E0; communication between left and right induction generator modules fails.

On Electrolux (Electrolux Infinite / Bridge / SenseBoil Induction Hob) models: Loose internal LIN-bus ribbon cable, oxidized molex pins, or missing 5V DC auxiliary power rail on secondary induction slave board.

Isolate hob from mains. Open casing and inspect interconnecting LIN ribbon cable. Measure continuity (< 1 Ω) and verify 5V DC on connector pin 1. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E01
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Electrolux Inspiration / TasteLock / TwinTech Refrigerator: Motorized air damper flap malfunction E01; damper flap fails to calibrate position, leading to incorrect fridge temperatures.

On Electrolux (Electrolux Inspiration / TasteLock / TwinTech Refrigerator) models: Frozen ice locking damper baffle door, stripped gear teeth in 12V DC stepper motor gear train (winding resistance ~350–450 Ω), or optical switch dirty.

Inspect air damper assembly located in duct between freezer and fridge. Defrost ice obstruction. Measure stepper motor windings (~400 Ω). Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E1
Hob / Cooktop
General System & Mechanical Integration

Electrolux Infinite / Bridge / SenseBoil Induction Hob: Touch control surface blocked E1; continuous touch actuation detected for longer than 10 seconds, disabling burners.

On Electrolux (Electrolux Infinite / Bridge / SenseBoil Induction Hob) models: Liquid boiling over touch keys, damp cloth placed over glass controls, metal lid resting on sensor area, or optical contamination.

Remove all cookware and foreign objects from touch zone. Clean ceramic glass surface with specialized scraper and microfiber cloth. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E02
Refrigerator / Freezer
Heating Element, Thermostat & Safety Fuse

Electrolux Inspiration / TasteLock / TwinTech Refrigerator: Automatic ice maker harvest error E02; ice mold ejector blades or twist tray mechanism fails to complete harvest cycle.

On Electrolux (Electrolux Inspiration / TasteLock / TwinTech Refrigerator) models: Deformed ice cube jamming ejector fingers, defective harvest gear motor (~2.2–3.0 kΩ coil resistance), or open ice mold heater element.

Clear jammed ice from mold. Run diagnostic ice maker test cycle. Measure harvest motor coil resistance (~2.5 kΩ) and mold heater resistance (~80–120 Ω). Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E2
Hob / Cooktop
NTC Temperature Sensor & Thermistor

Electrolux Infinite / Bridge / SenseBoil Induction Hob: Induction coil overheating alarm E2; induction zone temperature sensor exceeds allowable safety cutoff limit (> 240°C).

On Electrolux (Electrolux Infinite / Bridge / SenseBoil Induction Hob) models: Empty pan boiled dry at maximum boost power, non-induction pan with thin base concentrating extreme heat, or degraded silicone heat-sink paste on coil NTC.

Switch off cooking zone and allow hob to cool down for 20 minutes. Inspect cookware suitability with a magnet. Verify coil NTC resistance (~100 kΩ at 25°C). Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E03
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Electrolux Inspiration / TasteLock / TwinTech Refrigerator: Defrost condensate drain line frozen E03; water pools in bottom freezer drawer during defrost cycles.

On Electrolux (Electrolux Inspiration / TasteLock / TwinTech Refrigerator) models: Defrost drain pan heating probe open or missing aluminum heat-sink conductor strip down into drain funnel, causing re-freezing of melted water.

Flush drain funnel with hot water and clean silicone duckbill valve at rear compressor tray. Verify drain heater continuity (~1.2–1.8 kΩ). Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E3
Hob / Cooktop
General System & Mechanical Integration

Electrolux Infinite / Bridge / SenseBoil Induction Hob: Mains over-voltage detected E3; supply line voltage exceeds safe operating ceiling (> 275V AC), tripping safety shutdown.

On Electrolux (Electrolux Infinite / Bridge / SenseBoil Induction Hob) models: Accidental 400V 2-phase connection due to lost or disconnected neutral wire in terminal connection block, or grid lightning power surge.

Immediately disconnect hob. Check junction box with multimeter across L1-N and L2-N (must read ~230V AC; if ~400V, fix floating neutral wire). Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E3A
Washing Machine
Water Level Pressure Switch & Air Dome

Electrolux PerfectCare 600/700/800 UltraCare Washer: Heating element relay sensing circuit failure linked to pressure switch E3A on main motherboard.

On Electrolux (Electrolux PerfectCare 600/700/800 UltraCare Washer) models: Safety heater relay coil open on PCB, feedback sensing resistor burnt, or firmware communication error between relay driver and level logic.

Inspect heating element relay on main PCB (check 12V DC coil resistance ~400 Ω). Verify soldering joints on relay terminals. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E04
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Electrolux Inspiration / TasteLock / TwinTech Refrigerator: High temperature alarm in freezer compartment E04; freezer temperature rises above -9°C for sustained duration.

On Electrolux (Electrolux Inspiration / TasteLock / TwinTech Refrigerator) models: Refrigerant leak (loss of R600a charge), inefficient compressor valves, door left ajar, or severe frost buildup restricting airflow through evaporator.

Check magnetic door seal alignment. Inspect evaporator frost pattern (even frost coating indicates healthy charge; bare pipe indicates leak). Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E4
Hob / Cooktop
General System & Mechanical Integration

Electrolux Infinite / Bridge / SenseBoil Induction Hob: Mains under-voltage detected E4; electrical supply drops below minimum operating threshold (< 180V AC).

On Electrolux (Electrolux Infinite / Bridge / SenseBoil Induction Hob) models: Heavy power sag during neighborhood grid overload, undersized power supply cables causing high voltage drop under full load, or loose terminal screw.

Verify tight clamping on all terminal block screws. Measure incoming AC line voltage at terminal block under cooking load with true-RMS voltmeter. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E05
Refrigerator / Freezer
Door Lock Mechanism & Safety Interlock

Electrolux Inspiration / TasteLock / TwinTech Refrigerator: Door open sensor switch fault E05; interior LED lighting or open door chime stays on continuously.

On Electrolux (Electrolux Inspiration / TasteLock / TwinTech Refrigerator) models: Stuck magnetic reed switch inside control frame, dislodged door magnet on inner door profile, or worn push-button microswitch.

Test door switch continuity with door closed (< 1 Ω). Test reed switch by passing a handheld neodymium magnet over the sensor location. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E5
Hob / Cooktop
NTC Temperature Sensor & Thermistor

Electrolux Infinite / Bridge / SenseBoil Induction Hob: Induction power module heatsink over-temperature E5; cooling duct temperature sensor exceeds 95°C.

On Electrolux (Electrolux Infinite / Bridge / SenseBoil Induction Hob) models: Inlet cooling fan failed or obstructed by cutlery drawer beneath hob, blocked ventilation slot in kitchen worktop, or dust accumulation on fins.

Check clearance under hob (minimum 5mm front slot, 20mm rear airflow channel). Ensure cooling fan spins freely and blowers clear dust. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E5A
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

Electrolux PerfectCare 600/700/800 UltraCare Washer: Inverter module heat sink overheating alarm E5A; IGBT thermal sensor exceeds 88°C threshold.

On Electrolux (Electrolux PerfectCare 600/700/800 UltraCare Washer) models: Inverter housing air vents blocked with lint and dust, dried thermal paste between IGBT module and aluminum heat sink, or excessive ambient heat.

Vacuum dust from inverter module aluminum heat sink fins. Reapply thermal grease between power bridge and heat sink if detached. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E5C
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

Electrolux PerfectCare 600/700/800 UltraCare Washer: Inverter DC bus overvoltage alarm E5C; internal rectified DC voltage exceeds 430V DC safety limit.

On Electrolux (Electrolux PerfectCare 600/700/800 UltraCare Washer) models: Mains electrical grid voltage surge (> 275V AC), regenerative braking energy not absorbed during rapid spin deceleration, or damaged snubber diodes.

Measure mains AC voltage with true-RMS multimeter (should be 220–240V AC). If mains voltage is normal, inspect inverter DC bus electrolytic capacitors. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E5D
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

Electrolux PerfectCare 600/700/800 UltraCare Washer: Inverter serial communication timeout E5D; main motherboard loses UART data connection with motor inverter.

On Electrolux (Electrolux PerfectCare 600/700/800 UltraCare Washer) models: Broken data wire in serial communication cable loom, loose Molex connector pins, or missing 12V/5V DC logic power supply to inverter micro.

Check continuity of 4-wire serial communication cable between main board and inverter. Verify 12V DC auxiliary supply rail at inverter plug. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E5E
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

Electrolux PerfectCare 600/700/800 UltraCare Washer: Inverter microcontroller internal communication fault E5E; DSP processor self-diagnostic fails on boot.

On Electrolux (Electrolux PerfectCare 600/700/800 UltraCare Washer) models: Internal corruption of DSP firmware memory, crystal oscillator timing failure, or damaged internal logic voltage regulator on inverter board.

Perform complete 10-minute mains power discharge. If E5E persists on restart, replace defective motor inverter board (FCV module). Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E5F
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

Electrolux PerfectCare 600/700/800 UltraCare Washer: Inverter module continuous reset condition E5F; hardware watchdog timer resets inverter processor continuously.

On Electrolux (Electrolux PerfectCare 600/700/800 UltraCare Washer) models: Unstable 3.3V DC logic rail on inverter board, high ripple noise from dried switch-mode capacitors, or corrupted bootloader code.

Check for swollen electrolytic capacitors on inverter board. Verify clean 3.3V DC / 5V DC output with multimeter or replace inverter module. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E5H
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

Electrolux PerfectCare 600/700/800 UltraCare Washer: Inverter DC bus undervoltage alarm E5H; internal DC rail voltage drops below 175V DC during load.

On Electrolux (Electrolux PerfectCare 600/700/800 UltraCare Washer) models: Mains voltage sag (< 185V AC), high resistance in house electrical wall outlet, or failing rectifier bridge on inverter board.

Verify wall outlet voltage under load with washing machine running heating cycle. Check power cord plug blades for thermal pitting. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E06
Refrigerator / Freezer
Door Lock Mechanism & Safety Interlock

Electrolux Inspiration / TasteLock / TwinTech Refrigerator: Door dispenser communication error E06; water and ice dispenser touchscreen fails to send dispense commands.

On Electrolux (Electrolux Inspiration / TasteLock / TwinTech Refrigerator) models: Cable harness pinched or broken inside bottom door hinge bushing from repeated door openings, or oxidized dispenser connector.

Remove lower hinge cover plate. Inspect wire harness running through hinge pin. Check continuity of data and 12V supply lines (< 1 Ω). Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E6
Hob / Cooktop
Drive Motor, Inverter & Tachometer Sensor

Electrolux Infinite / Bridge / SenseBoil Induction Hob: Induction power inverter IGBT short circuit E6; power transistors on generator module damaged, tripping household breaker.

On Electrolux (Electrolux Infinite / Bridge / SenseBoil Induction Hob) models: IGBT semiconductor punch-through breakdown from thermal overload, failed resonant capacitors, or shorted copper induction coil windings.

Remove hob and open casing. Measure Collector-Emitter resistance of all IGBTs with multimeter (expected > 100 kΩ; if 0 Ω, replace module or IGBTs). Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E6H
Washing Machine
Heating Element, Thermostat & Safety Fuse

Electrolux PerfectCare 600/700/800 UltraCare Washer: Heating relay feedback sensing circuit anomaly E6H; motherboard detects relay status mismatch on power-up.

On Electrolux (Electrolux PerfectCare 600/700/800 UltraCare Washer) models: Failing auxiliary sensing contacts on safety heater relay, micro-cracks in PCB copper traces connecting relay to MCU, or defective optocoupler.

Inspect main PCB under magnifying glass for cracked solder joints around safety heater relay. Re-solder terminals or replace control board. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E07
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Electrolux Inspiration / TasteLock / TwinTech Refrigerator: Condenser cooling fan motor failure E07; machine compartment cooling blower stopped, causing compressor overheating.

On Electrolux (Electrolux Inspiration / TasteLock / TwinTech Refrigerator) models: Heavy dust matting obstructing condenser fins and fan blades, failing 230V shaded-pole or 12V DC motor, or seized sleeve bearings.

Vacuum compressor compartment thoroughly. Clean condenser coils with a radiator brush. Spin fan blades by hand to verify free movement. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
E7
Hob / Cooktop
Drive Motor, Inverter & Tachometer Sensor

Electrolux Infinite / Bridge / SenseBoil Induction Hob: Hob cooling fan motor fault E7; internal 12V DC cooling fan does not run or tachometer pulse signal is absent.

On Electrolux (Electrolux Infinite / Bridge / SenseBoil Induction Hob) models: Defective brushless fan motor, fan blades seized by stray wire or foreign debris, unseated fan connector, or blown fan driver circuit on PCB.

Inspect fan assembly. Spin blades by hand to verify smooth rotation. Measure 12V DC across fan pins during zone operation. Replace fan if seized. Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.

Diagnose
← Previous Page
Page 1 of 7 (191 results)Next Page →

Electrolux — Complete Error Code Catalog

167 Verified Error Codes

Server-side index of all verified manufacturer error codes for technicians and automated crawlers.

Dishwasher45

AL5AL6C1C2C3i5Ai5Bi5Ci5Di5Ei5Fi10i11i20i22i23i24i30i40i41i43i44i50i51i52i53i54i55i56i57i58i59i60i61i63i64i70i80i90iA0iB0iC0iD0iF0iF1

Washing Machine57

C9CFE3AE5AE5CE5DE5EE5FE5HE6HE9CE9EE10E11E12E13E20E21E22E23E24E25E33E34E35E38E40E41E42E43E44E45E66E68E69E74E82E83E84E85E94E95E97E98EA0EA1EA6EB0EF0EF1EF2EF3EF4EF5EH1EH2EH3

Tumble Dryer25

E30E31E32E50E51E52E53E54E57E58E59E60E61E62E63E70E71E72E73E80E90E91E92E93EH0

Oven / Microwave12

F101F102F103F104F105F106F107F108F109F110F111F112

Hob / Cooktop12

E0E1E2E3E4E5E6E7E8E9EAF

Refrigerator / Freezer16

E01E02E03E04E05E06E07F1F2F3F4F5F6F7SY EF5Y EF

Need Help? Call a Certified Technician

Our official certified partners service Electrolux appliances in your area.

Electroassistance (Switzerland)Appliance Care UK (United Kingdom)
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy