Electrolux Infinite / Bridge / SenseBoil Induction Hob: Power supply line communication missing E8; power board detects missing AC phase voltage on multi-phase terminal connection.
On Electrolux (Electrolux Infinite / Bridge / SenseBoil Induction Hob) models: Tripped individual phase breaker in distribution panel, loose phase jumper link in hob terminal box, or open contact in cooktop isolation switch.
Check electrical distribution board for tripped breakers. Measure AC voltage between each active phase and Neutral at hob terminal block (~230V AC each). Hold Start/Pause and Delay Start together for 5 seconds on program position 10 until the acoustic chime sounds and display resets to 0:00.