Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
Gaggenau • Central Diagnostic Dictionary
207 Verified Codes in Database

Gaggenau Error Codes & Diagnostics

Access our premium database of error codes, common faults, and professional repair solutions for Gaggenau appliances.

Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
CodeAppliancesFault / DiagnosticsRepair InstructionsAction
AL
Refrigerator / Freezer
General System & Mechanical Integration

Gaggenau 200 Series / 400 Series Vario Cooling dynamic refrigeration with stainless interior: High temperature cavity alarm AL; freezer temperature has risen above critical threshold of -9°C for over 60 minutes.

On Gaggenau refrigerators: Door left ajar for extended period, prolonged household power...

Press Alarm Silence key to mute buzzer. Ensure door seals adhere tightly with no gaps....

Diagnose
AL01
Refrigerator / Freezer
General System & Mechanical Integration

Freezer temperature is too high

The freezer door has been left open, a large amount of warm food was added, or there is a...

Check that the door is sealed properly. Avoid opening it for several hours to allow it to...

Diagnose
AL02
Refrigerator / Freezer
General System & Mechanical Integration

Refrigerator temperature is too high

The refrigerator door has been left open, or warm items were loaded. Can also indicate a...

Ensure the door is closed and that air vents inside are not blocked by food items. Wait a...

Diagnose
AL03
Refrigerator / Freezer
Door Lock Mechanism & Safety Interlock

Gaggenau AL03: Door lock safety interlock fault in Refrigerator / Freezer; door switch contact fails to close or open.

This is a generic alarm that could be related to various components, often a door being...

Check all doors and drawers to ensure they are fully closed. Press the 'Alarm Off' button...

Diagnose
d0
Hob / Cooktop
General System & Mechanical Integration

Gaggenau 200 Series / 400 Series Vario full-surface induction cooktop: Showroom demo mode active d0; displays and touch sliders illuminate and respond but power elements do not heat.

On Gaggenau hobs: Retail showroom test routine enabled during display installation or...

To exit demo mode: Turn hob off, press and hold Child Lock and Zone Boost keys together for...

Diagnose
d1
Hob / Cooktop
Drive Motor, Inverter & Tachometer Sensor

Gaggenau 200 Series / 400 Series Vario full-surface induction cooktop: Front left cooking zone demo test locked d1; front left inverter locked in display simulation loop.

On Gaggenau hobs: Zone-specific demo flag set in EEPROM non-volatile memory during factory...

Access engineering service menu by holding On/Off and Zone 1 select key for 4 seconds after...

Diagnose
d2
Hob / Cooktop
General System & Mechanical Integration

Gaggenau 200 Series / 400 Series Vario full-surface induction cooktop: Rear left cooking zone demo test locked d2; rear left induction channel disabled in demo simulation mode.

On Gaggenau hobs: Firmware zone configuration register uninitialized for rear left...

Perform complete cold reset via main breaker (cut power for 3 minutes). If d2 persists,...

Diagnose
d3
Hob / Cooktop
General System & Mechanical Integration

Gaggenau 200 Series / 400 Series Vario full-surface induction cooktop: Center / rear right cooking zone demo test locked d3; zone controller in exhibition simulation state.

On Gaggenau hobs: Interrupted factory programming script or uncalibrated expansion coil...

Restore factory configuration via touch sequence: Power On -> hold Timer and Key for 6s ->...

Diagnose
d4
Hob / Cooktop
General System & Mechanical Integration

Gaggenau 200 Series / 400 Series Vario full-surface induction cooktop: Front right cooking zone demo test locked d4; front right power stage disabled in store demonstration mode.

On Gaggenau hobs: Retail demonstrator profile activated across right cooking zone power bus...

Exit demo mode using the global deactivation sequence (hold Lock + Booster for 5 seconds),...

Diagnose
d5
Hob / Cooktop
General System & Mechanical Integration

Gaggenau 200 Series / 400 Series Vario full-surface induction cooktop: FlexInduction bridging relay check state d5; induction coil coupling relays engaged in diagnostic cycle.

On Gaggenau hobs: Diagnostic check mode triggered by power fluctuation during multi-zone...

Cycle mains power at breaker for 30 seconds. On boot, do not bridge zones for the first 15...

Diagnose
d6
Hob / Cooktop
General System & Mechanical Integration

Gaggenau 200 Series / 400 Series Vario full-surface induction cooktop: Forced high-speed cooling fan test mode active d6; fan runs continuously at maximum RPM for thermal evaluation.

On Gaggenau hobs: Factory thermal endurance diagnostic program initiated, or stuck...

Turn hob off. Press and hold Zone 2 and Zone 4 selection buttons simultaneously for 4...

Diagnose
d7
Hob / Cooktop
General System & Mechanical Integration

Gaggenau 200 Series / 400 Series Vario full-surface induction cooktop: Mains voltage telemetry feedback display d7; digital voltmeter diagnostic screen showing live input AC voltage.

On Gaggenau hobs: Field technician diagnostic screen opened for grid stability evaluation...

Press the Power (On/Off) key once to exit the telemetry screen. Compare indicated voltage...

Diagnose
d8
Hob / Cooktop
General System & Mechanical Integration

Gaggenau 200 Series / 400 Series Vario full-surface induction cooktop: Touch slider sensitivity calibration mode d8; user interface enters capacitive touch gain tuning display.

On Gaggenau hobs: Replacement glass thickness adjustment routine initiated or capacitive...

Do not touch glass surface for 30 seconds to allow calibration to finish automatically. If...

Diagnose
d9
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Gaggenau 200 Series / 400 Series Vario full-surface induction cooktop: Factory end-of-line (EOL) test loop active d9; automated manufacturing test routine repeating test steps.

On Gaggenau hobs: Test jumper left on service header during assembly or incomplete factory...

De-energize cooktop. Remove glass top and inspect service header on main power board;...

Diagnose
dE
Refrigerator / Freezer
General System & Mechanical Integration

Display shows 'dE' or 'Demo'

The appliance is in 'Demo Mode' or 'Shop Mode'. The cooling system is deactivated, but...

Consult the user manual for the specific button combination to deactivate Demo Mode. It...

Diagnose
E
Hob / Cooktop
General System & Mechanical Integration

Flashing 'E' on cooktop display

General electronics fault or overheating of internal components.

Turn off the cooktop at the circuit breaker for 10 minutes to reset. If the error reappears...

Diagnose
E0
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Gaggenau 200 Series / 400 Series Vario full-surface induction cooktop: Control unit configuration error E0; touch module EEPROM parameter mismatch prevents zone activation.

On Gaggenau hobs: Corrupted firmware memory, voltage spike during power surge, or...

Disconnect mains power for 60 seconds. If E0 persists, perform factory EOL reconfiguration...

Diagnose
E01
Dishwasher
Heating Element, Thermostat & Safety Fuse

Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Critical power module failure E01; heating circuit relay contacts open or welded on the main control board.

On Gaggenau dishwashers: Relay driver triac damaged by heater inrush current, high contact...

Disconnect mains power. Inspect power module in bottom right base. Measure heater...

Diagnose
E01
Tumble Dryer
General System & Mechanical Integration

Gaggenau 200 Series self-cleaning condenser heat pump dryer: Process air circulation blockage E01; lint filter or air channel clogged, stopping drying cycle.

On Gaggenau tumble dryers: Thick lint layer on door filter mesh, clogged lower heat...

Remove double door lint filter and wash under running warm water. Vacuum lower condenser...

Diagnose
E01
Refrigerator / Freezer
NTC Temperature Sensor & Thermistor

Gaggenau 200 Series / 400 Series Vario Cooling dynamic refrigeration with stainless interior: Fridge compartment temperature sensor failure E01; fresh food zone NTC sensor circuit open or shorted.

On Gaggenau refrigerators: Defective cabinet wall NTC thermistor, moisture ingress into...

Measure NTC resistance at power PCB: nominal ~5.0 kΩ at +25°C, ~16.3 kΩ at 0°C, and ~13.3...

Diagnose
E1
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Gaggenau 200 Series / 400 Series Vario full-surface induction cooktop: Internal bus communication failure E1; user interface loses serial data link with induction power generator.

On Gaggenau hobs: Dislodged multi-pin ribbon cable, oxidized connector pins, or dead 5V DC...

Check flat ribbon cable continuity between UI and power PCB (< 0.2 Ω). Verify stable 5.0V...

Diagnose
E02
Dishwasher
Electronic Control Board (PCB) & Bus Communications

Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Auxiliary heating relay malfunction E02; secondary safety relay on power PCB fails to close during water heating phase.

On Gaggenau dishwashers: Defective auxiliary PCB relay coil, loose connector terminal on...

Check wiring continuity between control board and heat pump terminals. Verify 12V DC coil...

Diagnose
E02
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Gaggenau 200 Series / 400 Series Vario Cooling dynamic refrigeration with stainless interior: Evaporator defrost temperature sensor fault E02; defrost termination NTC sensor out of range or open circuit.

On Gaggenau refrigerators: Thermal fatigue on evaporator copper tube clip sensor, frost ice...

Inspect evaporator coil behind freezer back wall. Measure defrost NTC resistance: ~5.0 kΩ...

Diagnose
E2
Hob / Cooktop
NTC Temperature Sensor & Thermistor

Gaggenau 200 Series / 400 Series Vario full-surface induction cooktop: Induction coil temperature sensor over-temperature E2; coil NTC thermistor registers > 240°C or short circuit.

On Gaggenau hobs: Empty pan heated on boost level, failed thermal paste on center coil NTC,...

Allow cooktop to cool. Measure coil center NTC resistance (~100 kΩ at 25°C, dropping to ~10...

Diagnose
E03
Dishwasher
Heating Element, Thermostat & Safety Fuse

Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Auxiliary heating relay circuit discrepancy E03; microprocessor detects inconsistent contact state across heating relays.

On Gaggenau dishwashers: Welded relay contacts, leakage current to ground on heating...

Measure heating element insulation resistance to ground (must be > 20 MΩ with 500V...

Diagnose
E03
Tumble Dryer
Heating Element, Thermostat & Safety Fuse

Gaggenau 200 Series self-cleaning condenser heat pump dryer: Maximum drying cycle time limit exceeded E03; laundry remains damp after programmed 4-hour cycle timeout.

On Gaggenau tumble dryers: Weak heating (heat pump refrigerant leak or burnt heating...

Ensure laundry is spun at min 1200 RPM in washer. Check heater resistance (~22–26 Ω) or...

Diagnose
E03
Refrigerator / Freezer
NTC Temperature Sensor & Thermistor

Gaggenau 200 Series / 400 Series Vario Cooling dynamic refrigeration with stainless interior: Chiller / VitaFresh compartment sensor fault E03; meat/fish preservation drawer NTC registers invalid readings.

On Gaggenau refrigerators: Pinched sensor cable behind drawer sliding rails, moisture...

Remove 0°C drawer. Inspect sensor clip and wiring harness. Test NTC resistance (~5.0 kΩ at...

Diagnose
E3
Hob / Cooktop
General System & Mechanical Integration

Gaggenau 200 Series / 400 Series Vario full-surface induction cooktop: Mains over-voltage detected E3; supply voltage on phase L1/L2 exceeds safe threshold of 275V AC.

On Gaggenau hobs: Floating or disconnected neutral line in household junction box, utility...

Immediately disconnect hob. Measure AC voltage between each Phase (L1, L2) and Neutral (N);...

Diagnose
E04
Dishwasher
Drive Motor, Inverter & Tachometer Sensor

Gaggenau 200 Series / 400 Series Zeolith & push-to-open dishwasher: Water switch diverter position feedback failure E04; upper/lower spray arm alternator disc position unknown.

On Gaggenau dishwashers: Defective microswitch inside water diverter, stripped plastic...

Access water diverter assembly beneath sump. Test synchronous motor winding resistance...

Diagnose
E04
Refrigerator / Freezer
NTC Temperature Sensor & Thermistor

Gaggenau 200 Series / 400 Series Vario Cooling dynamic refrigeration with stainless interior: Ambient room temperature sensor fault E04; external temperature NTC located at top hinge cover disconnected or open.

On Gaggenau refrigerators: Pinched wiring loom during door reversal procedure, dislodged...

Unclip upper door hinge cover. Inspect wiring for cuts or crushing. Measure ambient NTC...

Diagnose
← Previous Page
Page 1 of 7 (207 results)Next Page →

Gaggenau — Complete Error Code Catalog

170 Verified Error Codes

Server-side index of all verified manufacturer error codes for technicians and automated crawlers.

Dishwasher39

E01E02E03E04E05E06E07E08E09E10E11E12E13E14E15E16E17E18E19E20E21E22E23E24E25E26E27E28E29E30E31E3000E3100E3200E6101E6900E9000E9001E9210

Washing Machine48

E34E35E37E38E42E43E44E47E48E49E50E57E59E60E61E67F16F17F18F19F20F21F22F23F25F26F27F28F29F31F34F35F36F37F38F42F43F44F47F48F49F50F57F59F60F61F63F67

Tumble Dryer16

E32E36E51E52E53E54E55E56E63E71E72E73E74E75E89E90

Oven / Microwave22

E005E011E101E104E106E115E300E305E310E395E396E0532E845E5116E5123Er1Er2Er4Er6Er7Er8F04

Hob / Cooktop40

d0d1d2d3d4d5d6d7d8d9EE0E1E2E3E4E5E6E7E8E9E0513E7015E8207ER22ER26F0F1F2F3F4F5F6F7F8F9U1U2U3U400

Refrigerator / Freezer5

ALAL01AL02AL03dE

Need Help? Call a Certified Technician

Our official certified partners service Gaggenau appliances in your area.

Electroassistance (Switzerland)Appliance Care UK (United Kingdom)
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy