Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
Indesit • Central Diagnostic Dictionary
153 Verified Codes in Database

Indesit Error Codes & Diagnostics

Access our premium database of error codes, common faults, and professional repair solutions for Indesit appliances.

Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
CodeAppliancesFault / DiagnosticsRepair InstructionsAction
F05
Hob / Cooktop
General System & Mechanical Integration

Indesit Aria Induction & Ceramic Dual Zone Cooktop: Inductive coil pan detection resonance sensor failure F05; generator fails to detect pan presence or coil tuning circuit detuned.

On Indesit cooktops: Incompatible aluminum or copper cookware without magnetic base, cracked ferrite core segment beneath coil, or blown resonant capacitor.

Test cookware with handheld magnet (must stick firmly to bottom). Inspect induction coil ferrite bars for fractures. Measure resonant capacitor bank values. Disconnect mains power for 60 seconds, verify sensor glass area is completely dry, then reconnect.

Diagnose
F05
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

Indesit Aria & Turn&Cook Multifunction Oven: Pyrolytic door latch microswitch signal discrepancy F05; controller senses invalid combination of door open and lock position contacts.

On Indesit ovens: Deformed door latch hook, seized motorized cam drive, burnt microswitch leaf springs, or thermal expansion warping the latch bracket.

Inspect motorized door latch above cavity roof. Test continuity of both microswitches in open and locked positions (< 1 Ω closed). Replace latch assembly. Set knobs to '0', disconnect power at fuse board for 60 seconds, restore supply and set mechanical or digital timer.

Diagnose
F05
Washing Machine
NTC Temperature Sensor & Thermistor

Indesit Innex & Push&Go MyTime Washing Machine: Wash water temperature NTC sensor error F05; thermistor circuit detected open or shorted to chassis ground.

On Indesit washers: Damaged NTC probe wiring harness on Arcadia J9 or WAVE connector, corroded terminals, or internal thermistor pellet breakdown.

Measure NTC thermistor resistance at element collar: nominal ~12 kΩ at 20°C, ~4.8 kΩ at 25°C. Check wiring continuity to main board. Replace NTC probe if out of spec. Press and hold Start/Pause for 5 seconds until LEDs sequence, rotate selector to '0', and disconnect power for 60s.

Diagnose
F5
Dishwasher
Drainage System & Drain Pump

Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Wash rotor stalled or low spray pressure F5; circulation pump motor draws excessive current or spray arms fail to spin.

On Indesit dishwashers: Fruit pit, toothpick, or broken glass wedged inside circulation pump impeller, or defective motor run capacitor / BLDC drive.

Remove circulation pump assembly from sump. Clear debris from internal volute impeller. Test motor windings (BLDC 3-phase: 45–60 Ω symmetrical). Press and hold Start/Reset for 5 seconds until drain pump runs, wait 60 seconds, then power cycle ON/OFF.

Diagnose
F5
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Indesit Total NoFrost & Pure Wind Refrigerator: BioFresh / 0°C Chiller / FreshBox drawer NTC sensor fault F5; zero-degree precision climate zone fails to regulate.

On Indesit refrigerators (Indesit Push&Go one-touch architecture and Arcadia 2/3 / EVO-II microprocessor control platform): NTC probe cable pinched beneath crisper drawer rail, cracked sensor housing, or moisture contamination in connector.

Isolate mains power. Remove chiller drawer and inspect NTC sensor probe mounted in drawer air canal. Measure resistance (~16 kΩ at 0°C). Replace sensor. Press and hold Super Cool / Reset button for 5 seconds until indicator stops blinking and compressor engages.

Diagnose
F06
Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor

Indesit MyTime & Push&Go Condenser Tumble Dryer: Drum rotation tachometer pulse failure F06; motor runs but microcomputer receives no tachometric feedback within 5 seconds.

On Indesit tumble dryers: Broken poly-V drive belt, loose motor shaft tachometer magnet, disconnected tach harness plug, or worn idler tension spring.

Inspect drum drive belt tension around motor spindle and drum perimeter. Measure tachometer generator coil resistance (nominal 115–170 Ω). Replace belt if broken. Hold Start button for 5 seconds until progress lights flash, rotate selector to 0, clean lint filter.

Diagnose
F06
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Indesit Aria Induction & Ceramic Dual Zone Cooktop: Power board heatsink temperature exceeds 95°C limit F06; thermal protection automatically de-energizes induction generator stages.

On Indesit cooktops: Obstructed cabinet ventilation air gap (< 5mm beneath worktop), stalled cooling fan, or prolonged booster mode with multiple zones.

Verify minimum 5mm front ventilation slot below front edge of countertop. Ensure cooling fan spins freely without foreign debris. Allow 15 minutes to cool down. Disconnect mains power for 60 seconds, verify sensor glass area is completely dry, then reconnect.

Diagnose
F06
Oven / Microwave
NTC Temperature Sensor & Thermistor

Indesit Aria & Turn&Cook Multifunction Oven: Cavity thermal runaway or overtemperature limit exceeded F06; temperature probe detects cavity heat exceeding 320°C in standard bake mode.

On Indesit ovens: Welded heating element relay contacts on power board maintaining 230V to elements, or drifted temperature sensor reading.

Disconnect mains breaker immediately. Measure heating element relay contacts on power board (must read infinite ohms de-energized). Verify PT1000 sensor curve. Set knobs to '0', disconnect power at fuse board for 60 seconds, restore supply and set mechanical or digital timer.

Diagnose
F06
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

Indesit Innex & Push&Go MyTime Washing Machine: Motor drive tachometer failure F06; microcomputer receives no tachometric feedback pulses during drum rotation attempt.

On Indesit washing appliances: Tachometer coil ring loose on rear motor shaft, worn carbon brushes (< 15 mm), disconnected tach harness, or defective motor triac.

Measure tachometer coil resistance: 115–170 Ω. Check carbon brush length (replace if under 15 mm). Inspect rotor winding continuity (1.5–3.5 Ω). Press and hold Start/Pause for 5 seconds until LEDs sequence, rotate selector to '0', and disconnect power for 60s.

Diagnose
F6
Dishwasher
Drainage System & Drain Pump

Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Water inlet tap closed error F6; insufficient water fills sump during filling sequence, flow rate below 1.5 L/min.

On Indesit dishwashers: Supply stopcock closed, kinked inlet hose with integrated AquaStop valve, blocked sand filter, or line pressure below 0.5 bar.

Verify dynamic supply pressure at tap. Clean mesh filter in AquaStop connection nut. Measure inlet valve solenoid coil resistance (3.5–4.5 kΩ). Press and hold Start/Reset for 5 seconds until drain pump runs, wait 60 seconds, then power cycle ON/OFF.

Diagnose
F6
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Indesit Total NoFrost & Pure Wind Refrigerator: Motorized air damper flap position error F6; baffle flap jammed or microswitch feedback not detected during open/close sweep.

On Indesit refrigerators (Indesit Push&Go one-touch architecture and Arcadia 2/3 / EVO-II microprocessor control platform): Ice accumulation jamming damper flap mechanism, stripped reduction gear teeth, or burned stepper motor drive coils (~400 Ω).

Disconnect power. Remove air tower ducting. Check damper motor coil resistance (~400 Ω per phase). Clear frost blockage. Replace defective motorized damper unit. Press and hold Super Cool / Reset button for 5 seconds until indicator stops blinking and compressor engages.

Diagnose
F6E
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

Indesit Aria & Turn&Cook Multifunction Oven: High-voltage relay switching board line voltage anomaly F6E; zero-crossing detector detects erratic frequency or voltage spikes.

On Indesit ovens: Poor mains electrical connection at terminal block, floating neutral conductor in household panel, or degraded filter varistor on PCB.

Inspect mains terminal block behind oven and torque all screw terminals. Verify phase-to-neutral voltage (230V AC ± 10%) and phase-to-earth voltage. Set knobs to '0', disconnect power at fuse board for 60 seconds, restore supply and set mechanical or digital timer.

Diagnose
F07
Tumble Dryer
Heating Element, Thermostat & Safety Fuse

Indesit MyTime & Push&Go Condenser Tumble Dryer: Heating element relay contacts welded closed F07; power PCB senses continuous thermal draw when heating is commanded off.

On Indesit tumble dryers: High current electrical arcing welding relay armature contacts on main control module under heavy 2500W load.

Disconnect power immediately to prevent overheating. Test normally-open relay contacts with ohmmeter (must read open circuit). Replace heater relay or PCB. Hold Start button for 5 seconds until progress lights flash, rotate selector to 0, clean lint filter.

Diagnose
F07
Hob / Cooktop
Drive Motor, Inverter & Tachometer Sensor

Indesit Aria Induction & Ceramic Dual Zone Cooktop: Chassis cooling fan stalled or tachometer missing F07; power module disables induction heating when cooling blower fails.

On Indesit cooktops: Kitchen drawer contents or wiring pinching cooling fan impeller blades, worn sleeve bearings, or open fan motor winding.

Inspect cooling fan underneath cooktop casing for mechanical obstructions. Spin fan blades by hand. Test 12V DC operating voltage and tach pulse on fan plug. Disconnect mains power for 60 seconds, verify sensor glass area is completely dry, then reconnect.

Diagnose
F07
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

Indesit Aria & Turn&Cook Multifunction Oven: Pyrolytic door lock motor mechanical jam F07; motorized drive fails to complete locking or unlocking stroke within 45 seconds.

On Indesit ovens: Hardened grease seizing gear train, warped locking hook catching on door frame, or stripped nylon reduction cogs.

Access door lock motor beneath top cover. Clear mechanical binding and lubricate with high-temperature silicone grease. Measure motor winding (2.5–4.5 kΩ). Set knobs to '0', disconnect power at fuse board for 60 seconds, restore supply and set mechanical or digital timer.

Diagnose
F07
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

Indesit Innex & Push&Go MyTime Washing Machine: Motor triac short-circuit error F07; control PCB senses uncontrolled drum acceleration or welded motor driver contacts.

On Indesit washers: Punctured power triac semiconductor junction on main control board due to mains surge or motor winding transient spike.

Disconnect mains power. Measure resistance between A1 and A2 terminals of motor triac on power board (short = 0 Ω, replace triac or board). Verify motor insulation. Press and hold Start/Pause for 5 seconds until LEDs sequence, rotate selector to '0', and disconnect power for 60s.

Diagnose
F7
Dishwasher
Drainage System & Drain Pump

Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Flowmeter turbine sensor impulse fault F7; turbine fails to generate digital pulses while water fills tub.

On Indesit dishwashers: Lime scale jammed impeller in water matrix air break side jacket, or defective glass reed switch sensor board.

Inspect side water jacket (air break) for free rotation of turbine wheel. Test reed switch continuity on multimeter during water fill. Replace reed PCB or jacket. Press and hold Start/Reset for 5 seconds until drain pump runs, wait 60 seconds, then power cycle ON/OFF.

Diagnose
F7
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Indesit Total NoFrost & Pure Wind Refrigerator: Freezer evaporator air circulation fan motor error F7; fan blade rotation stalled or RPM speed tachometer signal absent.

On Indesit refrigerators (Indesit Push&Go one-touch architecture and Arcadia 2/3 / EVO-II microprocessor control platform): Heavy frost wrapping fan blades due to defrost failure, dried sleeve bearings, or disconnected 12V DC fan harness.

Disconnect mains power. Access evaporator compartment behind rear cover. Verify free rotation of fan blade. Check 12V DC supply voltage and tacho feedback. Replace fan. Press and hold Super Cool / Reset button for 5 seconds until indicator stops blinking and compressor engages.

Diagnose
F08
Tumble Dryer
Heating Element, Thermostat & Safety Fuse

Indesit MyTime & Push&Go Condenser Tumble Dryer: Heating element open circuit or heat pump compressor failure F08; air chamber temperature fails to rise by 5°C in 15 minutes.

On Indesit tumble dryers: Broken nichrome coil on dual heating element (28 Ω + 36 Ω), tripped manual high-limit stat, or seized heat-pump compressor.

Check red reset button on rear heater casing. Measure resistance of both heating circuits (approx 28 Ω and 36 Ω). In heat pump units, verify compressor windings. Hold Start button for 5 seconds until progress lights flash, rotate selector to 0, clean lint filter.

Diagnose
F08
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Indesit Aria Induction & Ceramic Dual Zone Cooktop: Auxiliary induction coil relay drive fault F08; relay driver IC on generator module fails to actuate coil zone switching contacts.

On Indesit cooktops: Burned relay coil, cracked solder joint on relay terminals, or defective ULN2003 relay driver chip on generator PCB.

Inspect generator PCB for cracked solder joints beneath induction zone switching relays. Measure relay coil resistance (nominal 350–450 Ω). Replace relay or PCB. Disconnect mains power for 60 seconds, verify sensor glass area is completely dry, then reconnect.

Diagnose
F08
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Indesit Aria & Turn&Cook Multifunction Oven: Upper grill / broil heating element open circuit F08; no current flows through top heating element circuit during broil selection.

On Indesit ovens: Burned-out nichrome element coil inside upper sheathed heating rod, oxidized spade connector, or open relay on power board.

Disconnect power. Remove rear panel and measure upper element resistance across outer and inner coils (nominal 20–35 Ω). Replace element if infinite ohms. Set knobs to '0', disconnect power at fuse board for 60 seconds, restore supply and set mechanical or digital timer.

Diagnose
F08
Washing Machine
Heating Element, Thermostat & Safety Fuse

Indesit Innex & Push&Go MyTime Washing Machine: Heating element earth leakage failure F08; insulation degradation detected between heater coil and appliance chassis earth.

On Indesit washing appliances: Internal magnesium oxide insulation breakdown inside heating tube due to scale accumulation or thermal stress.

Measure heater coil resistance (nominal 24–28 Ω, ~2050W). Test insulation resistance with 500V megohmmeter (must exceed > 20 MΩ to earth; replace element if lower). Press and hold Start/Pause for 5 seconds until LEDs sequence, rotate selector to '0', and disconnect power for 60s.

Diagnose
F8
Dishwasher
Water Level Pressure Switch & Air Dome

Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Sump water level inconsistency or diverter fault F8; OWI sensor optical reading conflicts with pressure calculation.

On Indesit dishwashers: Fat or grease film coating the optical sensor lens, heavy detergent foaming, or motorized diverter valve (MDV) stuck mid-position.

Clean optical OWI sensor face in sump bottom with warm soapy water and soft sponge. Verify diverter motor resistance (6.0–7.5 kΩ). Recalibrate optical sensor. Press and hold Start/Reset for 5 seconds until drain pump runs, wait 60 seconds, then power cycle ON/OFF.

Diagnose
F8
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Indesit Total NoFrost & Pure Wind Refrigerator: Automatic ice maker assembly fault F8; ice mold harvest rotation cycle timeout or tray thermistor out of range.

On Indesit refrigerators (Indesit Push&Go one-touch architecture and Arcadia 2/3 / EVO-II microprocessor control platform): Ice cube jammed in mold stripper finger, stripped gearbox drive gear, disconnected microswitch, or frozen fill tube.

Isolate power. Inspect ice maker tray for stuck cubes. Test harvest motor winding resistance (~3.5 kΩ to 5 kΩ). Clear ice blockage or replace ice maker unit. Press and hold Super Cool / Reset button for 5 seconds until indicator stops blinking and compressor engages.

Diagnose
F09
Tumble Dryer
Electronic Control Board (PCB) & Bus Communications

Indesit MyTime & Push&Go Condenser Tumble Dryer: Control board EEPROM configuration checksum error F09; processor detects corrupted model variant coding in memory.

On Indesit tumble dryers: Voltage fluctuation during drying cycle write operation, lightning grid surge, or memory silicon degradation.

Unplug unit for 15 minutes. If code returns upon power-up, reconfigure board with brand service tool or replace pre-programmed electronic control module. Hold Start button for 5 seconds until progress lights flash, rotate selector to 0, clean lint filter.

Diagnose
F09
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Indesit Aria Induction & Ceramic Dual Zone Cooktop: Touch UI microcontroller EEPROM calibration checksum fault F09; user interface configuration parameters fail validation test.

On Indesit cooktops: Voltage fluctuation during cooking zone level adjustment, corrupted calibration bytes in memory, or damaged touch MCU.

Disconnect power at distribution breaker for 10 minutes. If fault persists upon restore, reflash UI firmware or replace touch control module. Disconnect mains power for 60 seconds, verify sensor glass area is completely dry, then reconnect.

Diagnose
F09
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Indesit Aria & Turn&Cook Multifunction Oven: Lower bake heating element open circuit F09; bottom floor heating rod draws zero current during conventional bake mode.

On Indesit ovens: Thermal fatigue fracture in bottom heating rod coil, terminal lug burn-off beneath insulation mat, or open bake relay contacts.

Isolate power. Access lower element terminals from rear. Measure resistance (nominal 38–52 Ω, ~1100W–1300W). Check wiring and replace bottom element. Set knobs to '0', disconnect power at fuse board for 60 seconds, restore supply and set mechanical or digital timer.

Diagnose
F09
Washing Machine
Water Level Pressure Switch & Air Dome

Indesit Innex & Push&Go MyTime Washing Machine: Drum water overfill condition F09; safety overflow contact on pressure switch tripped or EEPROM parameter discrepancy detected.

On Indesit washers: Continuous mechanical water flow through stuck open inlet solenoid valve, or clogged air pressure trap holding high pressure.

Turn off water tap immediately. Check if water enters tub with machine unpowered (if yes, replace inlet valve). Inspect pressure switch contacts and air trap. Press and hold Start/Pause for 5 seconds until LEDs sequence, rotate selector to '0', and disconnect power for 60s.

Diagnose
F9
Dishwasher
Drainage System & Drain Pump

Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Continuous water fill detected F9; inlet valve fails to close or triac on power board leaks current, overfilling sump.

On Indesit dishwashers: Solenoid plunger stuck open mechanically by sand particle, or punctured triac semiconductor on main control module.

Turn off water tap. Unplug appliance. If water still flows into tub, replace dual inlet valve assembly. If stops, inspect board triac output. Press and hold Start/Reset for 5 seconds until drain pump runs, wait 60 seconds, then power cycle ON/OFF.

Diagnose
F9
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Indesit Total NoFrost & Pure Wind Refrigerator: Variable speed inverter compressor drive fault F9; compressor fails to start, trips on overcurrent, or loses phase sync.

On Indesit refrigerators (Indesit Push&Go one-touch architecture and Arcadia 2/3 / EVO-II microprocessor control platform): Damaged IPM intelligent power module on inverter PCB, open/shorted compressor 3-phase windings (~9.5 Ω balanced), or low line voltage.

Disconnect mains. Discharge high-voltage capacitors. Measure resistance between compressor terminals U-V, V-W, W-U (must be identical, ~9.5 Ω ±0.5 Ω). Replace inverter PCB. Press and hold Super Cool / Reset button for 5 seconds until indicator stops blinking and compressor engages.

Diagnose
← Previous PagePage 3 of 6 (153 results)Next Page →

Indesit — Complete Error Code Catalog

93 Verified Error Codes

Server-side index of all verified manufacturer error codes for technicians and automated crawlers.

Dishwasher28

E1E2E3E4E5E6E7E8E9F1F2F3F4F5F6F7F8F9F10F11F12F13F14F15FAFBFCFE

Washing Machine23

A01A02A03A04A05A06A07A08A10BDDF16F17F18F26F27F28F29FDLFDUFHFODH20SUD

Tumble Dryer14

F01F02F03F04F05F06F07F08F09F20F21F22F23F24

Oven / Microwave6

F1EF2EF3EF6ESAFESTOP

Hob / Cooktop13

C81C82C83C84C85F25F36F37F40F42F47HL

Refrigerator / Freezer9

A1A2AL01AL02AL03CECFdEPO

Need Help? Call a Certified Technician

Our official certified partners service Indesit appliances in your area.

Electroassistance (Switzerland)Appliance Care UK (United Kingdom)
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy