Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
Indesit • Central Diagnostic Dictionary
153 Verified Codes in Database

Indesit Error Codes & Diagnostics

Access our premium database of error codes, common faults, and professional repair solutions for Indesit appliances.

Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
CodeAppliancesFault / DiagnosticsRepair InstructionsAction
E8
Dishwasher
Drainage System & Drain Pump

Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Motorized water diverter valve positioning timeout E8; disc failed to reach selected spray level within 30 seconds.

On Indesit dishwashers: Stripped internal gear teeth inside MDV gearbox, seized motor rotor, or oxidized microswitch contact on MDV feedback wheel.

Inspect MDV motor housing beneath sump. Measure synchronous motor coil resistance (nominal 6.0–7.5 kΩ). Check microswitch continuity (< 1 Ω closed). Press and hold Start/Reset for 5 seconds until drain pump runs, wait 60 seconds, then power cycle ON/OFF.

Diagnose
E9
Dishwasher
Water Level Pressure Switch & Air Dome

Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Overfill chamber safety trip E9; water pressure transducer senses water level beyond maximum safety mark during fill.

On Indesit dishwashers: Short-circuited triac feeding constant 230V to inlet solenoid valve, or mineral sediment preventing valve armature closure.

Isolate mains power immediately. Check if water continues filling tub unpowered (valve mechanically failed). If stops, replace shorted power board. Press and hold Start/Reset for 5 seconds until drain pump runs, wait 60 seconds, then power cycle ON/OFF.

Diagnose
F01
Tumble Dryer
Drive Motor, Inverter & Tachometer Sensor

Indesit MyTime & Push&Go Condenser Tumble Dryer: Drum drive motor relay or triac failure F01; power PCB detects uncommanded drum rotation or shorted motor driver.

On Indesit tumble dryers (Indesit Push&Go one-touch architecture and Arcadia 2/3 / EVO-II microprocessor control platform): Welded motor start relay contacts on control board, or short-circuited motor triac semiconductor.

Disconnect mains power. Measure resistance across motor driver triac terminals (short = 0 Ω). Inspect power board for scorched relay pads. Hold Start button for 5 seconds until progress lights flash, rotate selector to 0, clean lint filter.

Diagnose
F01
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Indesit Aria Induction & Ceramic Dual Zone Cooktop: Induction power module bus disconnection F01; touch display board fails to establish LIN bus communication with induction generator.

On Indesit cooktops (Indesit Push&Go one-touch architecture and Arcadia 2/3 / EVO-II microprocessor control platform): Loose ribbon bus cable between touch sensor and filter module, blown low-voltage fuse on generator PCB, or power surge.

Isolate mains breaker. Open chassis housing and verify multi-pin ribbon cables between UI and generator boards. Measure 12V DC logic power rail. Disconnect mains power for 60 seconds, verify sensor glass area is completely dry, then reconnect.

Diagnose
F01
Oven / Microwave
NTC Temperature Sensor & Thermistor

Indesit Aria & Turn&Cook Multifunction Oven: Cavity temperature sensor probe open circuit F01; electronic controller reads infinite resistance across PT1000/NTC probe.

On Indesit ovens (Indesit Push&Go one-touch architecture and Arcadia 2/3 / EVO-II microprocessor control platform): Fractured platinum wire element inside metal stem, burned probe connector on rear casing, or rodent damage to insulation.

Isolate electrical supply. Remove rear cover panel. Measure sensor probe resistance: nominal ~1078 Ω at 20°C (PT1000) or ~540 Ω at 20°C (PT500). Replace probe. Set knobs to '0', disconnect power at fuse board for 60 seconds, restore supply and set mechanical or digital timer.

Diagnose
F01
Washing Machine
Water Level Pressure Switch & Air Dome

Indesit Innex & Push&Go MyTime Washing Machine: Water fill timeout fault F01; electronic control board registers failure to reach minimum wash water level within 6 minutes.

On Indesit washers (Indesit Push&Go one-touch architecture and Arcadia 2/3 / EVO-II microprocessor control platform): Closed inlet tap, blocked inlet valve mesh filter, defective solenoid coil, or failed analog pressure switch signal.

Verify dynamic water supply pressure (min 1.0 bar). Measure inlet valve solenoid coil resistance (nominal 3.5–4.5 kΩ). Check pressure hose. Press and hold Start/Pause for 5 seconds until LEDs sequence, rotate selector to '0', and disconnect power for 60s.

Diagnose
F1
Dishwasher
NTC Temperature Sensor & Thermistor

Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Wash water temperature sensor out of bounds F1; NTC thermistor reading open or shorted to sump chassis.

On Indesit dishwashers (Indesit Push&Go one-touch architecture and Arcadia 2/3 / EVO-II microprocessor control platform): Defective NTC sensor pellet inside OWI assembly, lime scale coating probe body, or wiring harness disconnect.

Measure NTC thermistor resistance at OWI connector: nominal ~48 kΩ at 25°C (~22 kΩ at 40°C, ~10 kΩ at 60°C). Replace OWI sensor if out of specification. Press and hold Start/Reset for 5 seconds until drain pump runs, wait 60 seconds, then power cycle ON/OFF.

Diagnose
F1
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Indesit Total NoFrost & Pure Wind Refrigerator: Freezer chamber temperature thermistor sensor error F1; digital display flashes temperature indicator or alarm beacon.

On Indesit refrigerators (Indesit Push&Go one-touch architecture and Arcadia 2/3 / EVO-II microprocessor control platform): Defective NTC sensor element in freezer cavity, broken wiring in back wall, or degraded terminal block pin contact.

Disconnect mains power. Measure freezer NTC probe resistance: nominal ~32 kΩ at -18°C, ~16 kΩ at 0°C, ~2.7 kΩ at 25°C. Replace sensor probe. Press and hold Super Cool / Reset button for 5 seconds until indicator stops blinking and compressor engages.

Diagnose
F1E
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

Indesit Aria & Turn&Cook Multifunction Oven: Internal hardware watchdog timer reset F1E; microcontroller encounters memory crash or execution trap and restarts in fault mode.

On Indesit ovens: High-voltage relay coil flyback transient spike, ripple on 3.3V logic regulator, or electrical noise from oven cooling blower.

Unplug oven for 10 minutes to reset all microcontroller capacitors. Verify stable 3.3V and 5V DC rails with oscilloscope. Replace power PCB if error repeats. Set knobs to '0', disconnect power at fuse board for 60 seconds, restore supply and set mechanical or digital timer.

Diagnose
F02
Tumble Dryer
Heating Element, Thermostat & Safety Fuse

Indesit MyTime & Push&Go Condenser Tumble Dryer: Drum drive motor stalled or thermal protector tripped F02; motor winding overheats and internal bimetallic klixon opens.

On Indesit tumble dryers: Seized drum support rollers, broken idler pulley bearing, defective motor run capacitor (10–16 µF), or jammed blower fan wheel.

Rotate drum by hand to check for mechanical binding. Test motor run capacitor with capacitance meter (10–16 µF). Check motor winding resistance (20–35 Ω). Hold Start button for 5 seconds until progress lights flash, rotate selector to 0, clean lint filter.

Diagnose
F02
Hob / Cooktop
General System & Mechanical Integration

Indesit Aria Induction & Ceramic Dual Zone Cooktop: Touch control surface overheating or liquid spill detected F02; capacitive keys automatically lock to prevent uncommanded activation.

On Indesit cooktops: Hot pan base placed directly onto front touch glass console, boiling pot overflowing saline water, or high ambient cabinet temperature.

Remove all cookware from touch glass area immediately. Wipe surface dry with clean microfiber towel. Allow 10 minutes to cool before restoring power. Disconnect mains power for 60 seconds, verify sensor glass area is completely dry, then reconnect.

Diagnose
F02
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Indesit Aria & Turn&Cook Multifunction Oven: Tangential cooling fan tachometer signal missing F02; safety interlock shuts off heating elements to prevent console overheating.

On Indesit ovens: Seized sleeve bearings in cross-flow cooling blower, loose Hall sensor PCB on motor bracket, or blocked upper air discharge flue.

Spin cross-flow fan drum by hand for mechanical freedom. Measure fan motor winding resistance (nominal 180–280 Ω). Verify 5V DC and pulse signal on Hall pins. Set knobs to '0', disconnect power at fuse board for 60 seconds, restore supply and set mechanical or digital timer.

Diagnose
F02
Washing Machine
Drainage System & Drain Pump

Indesit Innex & Push&Go MyTime Washing Machine: AquaStop safety base leak F02; safety float switch in base tray activated or drive motor triac short-circuit detected.

On Indesit washing appliances: Internal water leakage from tub gasket, dispenser hose, or drain bellows, tripping the polystyrene base float switch.

Isolate electrical supply. Remove rear panel and dry base tray. Inspect door boot seal and hose clamps for water leaks. Test float switch continuity (0 Ω closed). Press and hold Start/Pause for 5 seconds until LEDs sequence, rotate selector to '0', and disconnect power for 60s.

Diagnose
F2
Dishwasher
Drainage System & Drain Pump

Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: AquaStop base tray leak detected F2; flood safety float microswitch activated and drain pump forced into continuous evacuation.

On Indesit dishwashers: Hydraulic water leak from circulation pump shaft seal, sump gasket O-ring, water inlet fill hose, or tub perforation.

Disconnect electricity. Remove plinth kickplate and absorb water in base pan. Locate dripping joint with dry towel. Replace defective seal or circulation pump. Press and hold Start/Reset for 5 seconds until drain pump runs, wait 60 seconds, then power cycle ON/OFF.

Diagnose
F2
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Indesit Total NoFrost & Pure Wind Refrigerator: Evaporator defrost sensor circuit error F2; automatic NoFrost defrost cycle interrupted or fails to execute properly.

On Indesit refrigerators (Indesit Push&Go one-touch architecture and Arcadia 2/3 / EVO-II microprocessor control platform): Open circuit or shorted defrost NTC on evaporator coil, moisture ingress inside heat-shrink seal, or oxidized plug contacts.

Disconnect power. Dismantle freezer inner rear backplate. Inspect defrost NTC sensor (~2.7 kΩ at 25°C, ~16 kΩ at 0°C). Replace defrost sensor assembly. Press and hold Super Cool / Reset button for 5 seconds until indicator stops blinking and compressor engages.

Diagnose
F2E
Oven / Microwave
General System & Mechanical Integration

Indesit Aria & Turn&Cook Multifunction Oven: Capacitive touch interface key stuck active F2E; console registers continuous button press exceeding 30 seconds threshold.

On Indesit ovens: Grease film or liquid spills over capacitive touch area, excessive mechanical pressure against front glass panel, or damaged sensor electrode.

Wipe glass fascia dry with clean microfiber towel and glass cleaner. Ensure no objects lean against touch area. Power cycle unit to recalibrate touch baseline. Set knobs to '0', disconnect power at fuse board for 60 seconds, restore supply and set mechanical or digital timer.

Diagnose
F03
Tumble Dryer
NTC Temperature Sensor & Thermistor

Indesit MyTime & Push&Go Condenser Tumble Dryer: Front air duct NTC thermistor fault F03; process air temperature sensor signal detected open or shorted to chassis.

On Indesit tumble dryers: Lint accumulation insulating the NTC thermistor probe, fractured wiring lead behind front bulkhead, or internal sensor pellet failure.

Remove lint filter and vacuum NTC probe housing. Measure NTC resistance at terminals: nominal ~12 kΩ at 20°C (~4.8 kΩ at 25°C). Replace sensor if out of range. Hold Start button for 5 seconds until progress lights flash, rotate selector to 0, clean lint filter.

Diagnose
F03
Hob / Cooktop
NTC Temperature Sensor & Thermistor

Indesit Aria Induction & Ceramic Dual Zone Cooktop: Induction power module heatsink NTC temperature sensor fault F03; thermistor circuit detected open or shorted to ground.

On Indesit cooktops: Thermal paste drying out on aluminum heatsink thermistor, fractured surface-mount NTC sensor, or disconnected sensor plug on PCB.

Open bottom chassis. Measure heatsink NTC thermistor resistance (nominal ~10 kΩ at 25°C, or ~100 kΩ depending on board version). Renew thermal grease. Disconnect mains power for 60 seconds, verify sensor glass area is completely dry, then reconnect.

Diagnose
F03
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

Indesit Aria & Turn&Cook Multifunction Oven: Control board EEPROM calibration checksum error F03; oven parameters fail integrity check and lock heating programs.

On Indesit ovens: Mains power cut during pyrolytic cycle cooling phase, electrical noise transient, or aging flash memory cells.

Turn selector to 0. Isolate circuit breaker for 5 minutes. Restore power and reset clock. If error returns, reflash configuration or replace main PCB. Set knobs to '0', disconnect power at fuse board for 60 seconds, restore supply and set mechanical or digital timer.

Diagnose
F03
Washing Machine
Drainage System & Drain Pump

Indesit Innex & Push&Go MyTime Washing Machine: Water drainage timeout error F03; drain pump fails to evacuate drum wash water within 4 minutes.

On Indesit washers: Sump filter clogged with debris, drain hose kinked or siphon blocked, or drain pump motor winding open circuit.

Unscrew and clean front coin trap filter. Measure synchronous drain pump winding resistance (nominal 160–185 Ω) or BLDC winding (30–45 Ω). Check 230V AC supply. Press and hold Start/Pause for 5 seconds until LEDs sequence, rotate selector to '0', and disconnect power for 60s.

Diagnose
F3
Dishwasher
Drainage System & Drain Pump

Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Wash heating system failure F3; wash water does not achieve target temperature within 25 minutes of heating phase.

On Indesit dishwashers: Open-circuit tubular flow-through heating element, burnt PCB heater relay contacts, or tripped thermal safety limit cutouts.

Measure flow-through heater resistance (nominal 24–29 Ω, ~2040W). Check thermal cutouts on heater housing (0 Ω continuity). Verify 230V AC output from PCB relay. Press and hold Start/Reset for 5 seconds until drain pump runs, wait 60 seconds, then power cycle ON/OFF.

Diagnose
F3
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Indesit Total NoFrost & Pure Wind Refrigerator: Ambient room temperature sensor error F3; appliance cannot compensate refrigeration cycle for climate class variations.

On Indesit refrigerators (Indesit Push&Go one-touch architecture and Arcadia 2/3 / EVO-II microprocessor control platform): Open circuit or damaged NTC mounted on control console, fractured PCB track, or extreme room temperature (<10°C / >43°C).

Check ambient room temperature (must be 16°C–38°C for SN/T class). Measure ambient NTC sensor resistance on user interface PCB (~2.7 kΩ at 25°C). Replace board. Press and hold Super Cool / Reset button for 5 seconds until indicator stops blinking and compressor engages.

Diagnose
F3E
Oven / Microwave
NTC Temperature Sensor & Thermistor

Indesit Aria & Turn&Cook Multifunction Oven: Cavity NTC thermistor reading out of calibration range F3E; measured temperature deviates from model reference curve.

On Indesit ovens: Thermal aging and ceramic crystal degradation of NTC pellet caused by prolonged 280°C pyrolytic cleaning cycles.

Test sensor probe resistance across varying temperatures: ~1078 Ω at 20°C (rising to ~1385 Ω at 100°C for PT1000). Replace probe if non-linear. Set knobs to '0', disconnect power at fuse board for 60 seconds, restore supply and set mechanical or digital timer.

Diagnose
F04
Tumble Dryer
Drainage System & Drain Pump

Indesit MyTime & Push&Go Condenser Tumble Dryer: Condensate evacuation pump failure F04; water collector sump float switch triggers full warning with tank unseated or pump stalled.

On Indesit tumble dryers: Sludge and wet lint choking lower pump sump, jammed impeller, broken delivery hose, or open condensate pump coil.

Access lower rear pump housing. Flush condensate collection sump with warm water. Measure pump motor winding resistance (nominal 600–900 Ω or 160–250 Ω). Hold Start button for 5 seconds until progress lights flash, rotate selector to 0, clean lint filter.

Diagnose
F04
Hob / Cooktop
Drive Motor, Inverter & Tachometer Sensor

Indesit Aria Induction & Ceramic Dual Zone Cooktop: Mains supply undervoltage or missing phase error F04; inverter detects line voltage falling below 175V AC or missing phase on dual-rail feed.

On Indesit cooktops: Blown fuse on one branch of 2-phase supply, loose neutral screw terminal on connection block, or heavy grid voltage sag.

Verify incoming line voltage with digital multimeter: Phase 1 to Neutral must read 230V AC ± 10%, Phase 2 to Neutral 230V AC, Phase 1 to Phase 2 400V AC. Disconnect mains power for 60 seconds, verify sensor glass area is completely dry, then reconnect.

Diagnose
F04
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

Indesit Aria & Turn&Cook Multifunction Oven: User interface to power PCB bus communication lost F04; display controller cannot handshake with relay switching board.

On Indesit ovens: Heat-damaged ribbon cable between fascia and lower rear compartment, oxidized connector terminals, or 12V DC power sag.

Inspect data ribbon cable for melted insulation. Reseat connectors with electronic contact spray. Check 12V DC and 5V DC regulated outputs on power PCB. Set knobs to '0', disconnect power at fuse board for 60 seconds, restore supply and set mechanical or digital timer.

Diagnose
F04
Washing Machine
Water Level Pressure Switch & Air Dome

Indesit Innex & Push&Go MyTime Washing Machine: Water level sensor signal fault F04; analog pressure sensor reading stuck on empty level or output frequency out of range.

On Indesit washing machines: Air bell pressure tube split, blocked with detergent residue, or defective electronic analog transducer switch.

Inspect flexible pressure hose for pinholes and clear air chamber. Measure sensor supply voltage (5V DC) and output frequency (approx 21–26 Hz empty). Press and hold Start/Pause for 5 seconds until LEDs sequence, rotate selector to '0', and disconnect power for 60s.

Diagnose
F4
Dishwasher
Water Level Pressure Switch & Air Dome

Indesit Push&Go & Extra Hygiene DFP Series Dishwasher: Draining timeout failure F4; water level in hydraulic sump fails to drop below empty threshold within 4 minutes.

On Indesit dishwashers: Sump microfilter blocked by food soil, kinked drain hose, blocked non-return flap valve, or jammed drain pump impeller.

Remove and wash central fine mesh filters. Check drain impeller under sump cover for glass shards. Measure pump coil resistance (160–185 Ω). Press and hold Start/Reset for 5 seconds until drain pump runs, wait 60 seconds, then power cycle ON/OFF.

Diagnose
F4
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Indesit Total NoFrost & Pure Wind Refrigerator: Fresh food refrigerator compartment air sensor error F4; compartment fails to regulate target chilling temperature.

On Indesit refrigerators (Indesit Push&Go one-touch architecture and Arcadia 2/3 / EVO-II microprocessor control platform): NTC air thermistor open or shorted inside fresh food liner, damaged protective grille, or corroded connector pin.

Unplug appliance. Locate air sensor inside refrigerator liner behind cover. Measure resistance: ~7.8 kΩ at 4°C, ~2.7 kΩ at 25°C. Replace sensor probe. Press and hold Super Cool / Reset button for 5 seconds until indicator stops blinking and compressor engages.

Diagnose
F05
Tumble Dryer
Electronic Control Board (PCB) & Bus Communications

Indesit MyTime & Push&Go Condenser Tumble Dryer: Electronic moisture conductivity sensor fault F05; sensor bars in drum front collar read out-of-bounds impedance value.

On Indesit tumble dryers: Fabric softener or calcium residue insulating metallic sensor strips, disconnected sensor ground wire, or failed amplifier PCB.

Scrub twin sensor bars with white vinegar and abrasive scotch-brite pad to remove invisible wax coating. Check wiring continuity to control module. Hold Start button for 5 seconds until progress lights flash, rotate selector to 0, clean lint filter.

Diagnose
← Previous PagePage 2 of 6 (153 results)Next Page →

Indesit — Complete Error Code Catalog

93 Verified Error Codes

Server-side index of all verified manufacturer error codes for technicians and automated crawlers.

Dishwasher28

E1E2E3E4E5E6E7E8E9F1F2F3F4F5F6F7F8F9F10F11F12F13F14F15FAFBFCFE

Washing Machine23

A01A02A03A04A05A06A07A08A10BDDF16F17F18F26F27F28F29FDLFDUFHFODH20SUD

Tumble Dryer14

F01F02F03F04F05F06F07F08F09F20F21F22F23F24

Oven / Microwave6

F1EF2EF3EF6ESAFESTOP

Hob / Cooktop13

C81C82C83C84C85F25F36F37F40F42F47HL

Refrigerator / Freezer9

A1A2AL01AL02AL03CECFdEPO

Need Help? Call a Certified Technician

Our official certified partners service Indesit appliances in your area.

Electroassistance (Switzerland)Appliance Care UK (United Kingdom)
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy