Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code A1 registered by the microcomputer controller. Freezer compartment high temperature warning (> -9°C)
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code A2 registered by the microcomputer controller. Refrigerator compartment high temperature warning (> +10°C)
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès LTE / LPE Maxi Plate 14-Place Integrated Dishwasher: Diagnostic fault code A04 registered by the microcomputer controller. Wash water temperature sensor NTC open or short circuit
Scholtès LTE / LPE Maxi Plate 14-Place Integrated Dishwasher: Diagnostic fault code A06 registered by the microcomputer controller. Water fill timeout / flowmeter pulses missing or tap closed
Scholtès LTE / LPE Maxi Plate 14-Place Integrated Dishwasher: Diagnostic fault code A12 registered by the microcomputer controller. Communication loss between user interface and main board
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Alarm code AL04 indicates prolonged AC mains power outage; internal cabinet temperature rose above safe food storage threshold.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Status code CC indicates continuous cooling or fast freeze mode has run continuously for over 24 hours without cycling off.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code CI indicates ice maker harvest arm motor stalled; ejector blades jammed against ice cubes in mold.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Status notification dF indicates defrost cycle in progress; compressor and fan paused while calrod heater operates.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E1 registered by the microcomputer controller. Touch key panel obstructed / liquid spill or object over controls
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E5 registered by the microcomputer controller. Internal communication loss between touch UI and power generator module
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E6 registered by the microcomputer controller. Power module heatsink temperature sensor over-temperature (>95°C)
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E7 registered by the microcomputer controller. Induction coil temperature sensor NTC open or short circuit
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E9 registered by the microcomputer controller. User interface touch configuration checksum error
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code E9 indicates critical high temperature condition inside cabinet; perishable food at risk of spoiling.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic error ER CF indicates condenser cooling fan motor stall or feedback signal loss; compressor overheating danger.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code ER dS indicates defrost NTC thermistor open or short circuit; defrost cycle duration strictly time-limited.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code ER FF indicates freezer evaporator fan motor stalled or drawing excessive current; freezing performance lost.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code ER rF indicates fresh food compartment circulating fan motor stall; poor temperature distribution in refrigerator.
Scholtès Heat Pump Sensor Dry Tumble Dryer: Drum drive motor relay or triac failure F01; power PCB detects uncommanded drum rotation or shorted motor driver.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F01 registered by the microcomputer controller. Induction generator left rear zone IGBT driver fault
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F01 indicates fresh food compartment evaporator NTC sensor out of calibration or open circuit.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F01 registered by the microcomputer controller. Motor triac short-circuit / motor runaway protection
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F1 registered by the microcomputer controller. Refrigerator compartment air temperature NTC sensor failure
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F02 registered by the microcomputer controller. Induction generator left front zone IGBT driver fault
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F02 indicates freezer evaporator NTC sensor out of calibration or short-circuit detected.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F02 registered by the microcomputer controller. Motor tachometer generator open / no pulses received
Scholtès Heat Pump Sensor Dry Tumble Dryer: Front air duct NTC thermistor fault F03; process air temperature sensor signal detected open or shorted to chassis.
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F03 registered by the microcomputer controller. Induction generator right rear zone IGBT driver fault
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F03 registered by the microcomputer controller. Wash water temperature NTC sensor open or short circuit
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F3 registered by the microcomputer controller. Freezer compartment air temperature NTC sensor failure
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F04 registered by the microcomputer controller. Induction generator right front zone IGBT driver fault
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F04 indicates motorized air damper position sensor feedback switch open or shorted.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F04 registered by the microcomputer controller. Water level pressure switch stuck on empty state
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F05 registered by the microcomputer controller. Induction coil NTC thermistor disconnected or open circuit
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F05 indicates defrost heater circuit open circuit; defrost cycle aborted due to zero current draw.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F05 registered by the microcomputer controller. Drain pump blocked or pressure switch stuck on full state
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F5 registered by the microcomputer controller. Ambient room temperature NTC sensor failure
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F06 registered by the microcomputer controller. Induction coil NTC thermistor shorted to chassis or ground
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F06 registered by the microcomputer controller. Program selector switch position contact defect
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F07 registered by the microcomputer controller. Tangential cooling fan motor open or Hall tachometer failure (<700 RPM)
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F07 indicates evaporator fan Hall-effect speed feedback pulse missing; fan runs in fail-safe mode.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F07 registered by the microcomputer controller. Wash heating element relay open or heater element open circuit (~26 Ω)
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F7 registered by the microcomputer controller. Evaporator defrost heating element open circuit or thermal fuse blown
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Heat Pump Sensor Dry Tumble Dryer: Heating element open circuit or heat pump compressor failure F08; air chamber temperature fails to rise by 5°C in 15 minutes.
Immersion / Air Heating Element & Klixon Thermostat
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F08 registered by the microcomputer controller. Auxiliary DC power supply rail out of tolerance (+5V/+12V rail drop)
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F08 indicates condenser cooling fan motor circuit open or stalled; high condensing pressure and compressor thermal tripping.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F09 registered by the microcomputer controller. Communication loss between user display board and power PCB
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F09 indicates user interface (UI) display board communication timeout; control panel keys fail to respond.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F09 registered by the microcomputer controller. Main control board EEPROM setup checksum failure
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F9 registered by the microcomputer controller. Motorized air damper flap position sensor failure / flap stuck
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Electronic range control (ERC) EEPROM checksum fault F1 E0; oven display beeps continuously and disables all bake modes.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F10 registered by the microcomputer controller. Variable speed inverter compressor communication error
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F10 registered by the microcomputer controller. Pressure switch signal simultaneous empty and full (inconsistent)
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Scholtès Supreme Inox & Touch-Control Dishwasher: Main electronic control board relay malfunction F1 E1; dishwasher fails to execute wash cycles and beeps on power-up.
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Relay board microprocessor communication failure F1 E1; oven elements fail to energize and error tones sound.
Scholtès Heat Pump Sensor Dry Tumble Dryer: UI to main control board serial communication timeout F11; console display fails to synchronize packets with power board.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F11 registered by the microcomputer controller. Freezer evaporator brushless DC fan motor stalled / no tacho
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F1E1 indicates main electronic control board MCU microprocessor failure; internal relays fail to engage.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F12 registered by the microcomputer controller. User interface EEPROM data mismatch with power stage
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F12 registered by the microcomputer controller. Display board communication loss with main control board
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F13 registered by the microcomputer controller. Dryer NTC sensor open or short circuit (Washer-Dryer)
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F14 registered by the microcomputer controller. Dryer heating element open circuit (Washer-Dryer)
Scholtès Heat Pump Sensor Dry Tumble Dryer: Drum belt tensioner safety switch open F15; microswitch on motor jockey arm trips due to loose or broken drive belt.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F17 registered by the microcomputer controller. Door interlock delayed locking / PTC microswitch open
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Shorted keypad touch pad switch F2 E0; oven control registers a continuously depressed key and locks out panel.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Heat Pump Sensor Dry Tumble Dryer: Display to power module serial handshake loss F21; communication line fails periodic liveness heartbeat check.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F2E1 indicates communication loss between user interface display panel and main control board.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Supreme Inox & Touch-Control Dishwasher: User interface to electronic control board communication loss F2 E2; console display goes dark or flashes intermittently.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F2E2 registers user interface supply voltage abnormal; dispenser screen flickers or resets erratically.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F28 registered by the microcomputer controller. User interface display communication timeout with power board
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Supreme Inox & Touch-Control Dishwasher: Thermistor NTC water temperature sensor fault F3 E1; wash cycle runs excessively long or water fails to reach sanitize temp.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F3E1 indicates fresh food compartment (RC) NTC thermistor open or short circuit; cabinet temperature fluctuates wildly.
Scholtès Supreme Inox & Touch-Control Dishwasher: Wash water heating fault F3 E3; control board detects no temperature rise after 30 minutes of continuous wash operation.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F3E5 indicates freezer evaporator defrost thermistor open or out of limits; defrost heater fails to terminate correctly.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F4E1 indicates fresh food compartment evaporator fan motor stalled or disconnected; air circulation fails.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Supreme Inox & Touch-Control Dishwasher: Circulation wash motor drive triac fault F4 E2; wash pump motor fails to start or runs uncommanded at full speed.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F4E2 indicates freezer evaporator fan motor stall or tachometer feedback failure; freezer warms rapidly.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F4E4 indicates in-door ice box blower fan motor blocked or disconnected; ice melting in storage bin.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F47 registered by the microcomputer controller. LIN-bus communication error between touch display and power module
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F48 registered by the microcomputer controller. Induction zone booster power limiter jumper missing or invalid
Immersion / Air Heating Element & Klixon Thermostat
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F49 registered by the microcomputer controller. Capacitive touch controller I2C communication bus error
Immersion / Air Heating Element & Klixon Thermostat
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F5E1 indicates French door interlock switch or vertical mullion heater open; condensation forms on cabinet flange.
Immersion / Air Heating Element & Klixon Thermostat
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F5E2 indicates dispenser ice chute motorized flapper door failed to open or close; air leaks frost the chute.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F5E3 indicates motorized air damper door stuck open or closed; fresh food section either freezes or warms up.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F6E1 indicates serial communication timeout between main control board and door dispenser display.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F6E2 indicates communication loss between main power board and variable frequency inverter compressor driver.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F8E1 indicates primary water inlet solenoid valve electrical fault; water dispenser and ice maker starved of water.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F8E2 indicates ice maker fill valve flow meter timeout; insufficient water volume dosed into ice tray.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Status notification FB indicates water filter bypass plug is installed; water dispenser operating without active carbon filtration.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code H1 indicates critical over-temperature condition in freezer; compartment temperature rose above 0°C.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code H2 indicates fresh food compartment temperature elevated above +16°C; loss of refrigeration cooling capacity.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code H20 registered by the microcomputer controller. Water filling timeout / inlet valve or tap pressure failure
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code HC indicates high cabinet temperature warning; freezer compartment exceeded -5°C for longer than 60 minutes.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code L registered by the microcomputer controller. Child lock safety active / controls locked
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code LC indicates low temperature condition in fresh food compartment; fresh vegetables freezing on bottom crisper shelves.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Status notification OF indicates cooling off or showroom demo mode is active; display operates but cooling system is shut down.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code OV indicates inverter driver DC link over-voltage trip; compressor shut down to protect power semiconductors.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code P1 indicates delicatessen pantry drawer temperature sensor circuit open or shorted.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code PF indicates power failure event occurred; electronic control board clock reset and alarm flashes.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code SY CE indicates system communication error between user interface touch panel and main control board.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code SY EF indicates system evaporator fan circuit malfunction; zero rotational feedback detected by electronic control.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code U400 registered by the microcomputer controller. Voltage connection fault (400V 2-phase connected across single 230V rail)
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code 7E indicates external ambient temperature sensor analog channel error; control defaults to 22°C nominal room reference.
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F04 registered by the microcomputer controller. Cavity over-temperature (>325°C in convection or >535°C in pyrolytic)
On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: heating relay stuck closed or sensor drift Metrological tolerance verification: tubular heating element resistance nominal 26.5 Ω to 28.5 Ω (2000W / 230V AC).
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure resistance across heating element terminals (expected ~27.5 Ω). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F04 indicates motorized air damper position sensor feedback switch open or shorted.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Defective microswitch inside damper housing, broken cam lobe on stepper gearbox, or wiring harness fault (coils: 200–400 Ω).
Disconnect power. Remove air distribution duct in fresh food liner. Test continuity of feedback switch while cycling door manually (0 Ω closed, infinite Ω open). Replace damper if faulty. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F04 registered by the microcomputer controller. Water level pressure switch stuck on empty state
On Scholtès appliances engineered with Arcadia 2 heavy-duty inverter drive with digital inductive pressure sensor, dynamic drum unbalance detection, and ceramic-coated heating element: pressure switch contacts failed to change state Metrological tolerance verification: drain pump synchronous motor coil nominal 165 Ω to 180 Ω (230V AC).
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure drain pump coil resistance across terminals (expected ~170 Ω). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn selector knob to Reset/Cancel (or Off). Press and hold the Start/Pause button for 6 seconds until the drain pump runs momentarily and door lock clicks open, indicating clearing of fault code.
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F4 registered by the microcomputer controller. Freezer evaporator defrost NTC sensor failure
On Scholtès appliances engineered with Dynamic Air Cooling airflow with multi-sensor evaporator defrost cycle, bi-stable refrigerant distribution valve, and high-efficiency hermetic compressor: freezer defrost termination thermistor out of tolerance Metrological tolerance verification: nominal 2.7 kΩ at 25°C, 24.0 kΩ at -15°C..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: test sensor across defrost pins; ensure no short to evaporator tubing. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press the Holiday / Eco mode and Fast Freeze buttons simultaneously for 5 seconds until the display flashes twice and the audible alarm silences.
On Scholtès tumble dryers: Fabric softener or calcium residue insulating metallic sensor strips, disconnected sensor ground wire, or failed amplifier PCB.
Scrub twin sensor bars with white vinegar and abrasive scotch-brite pad to remove invisible wax coating. Check wiring continuity to control module. Switch selector to Stop, press and hold Start/Pause for 5 seconds to clear error memory, then power off for 1 minute.
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F05 registered by the microcomputer controller. Induction coil NTC thermistor disconnected or open circuit
On Scholtès appliances engineered with Arcadia / E.G.O. high-frequency induction power modules with digital temperature monitoring across each inductor core, touch slider filtering, and dynamic phase balancing: thermistor wire severed Metrological tolerance verification: nominal 100.0 kΩ at 25°C..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure coil sensor resistance on power board connector. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Ensure all cookware is removed and glass is completely dry. Turn off mains isolator switch for 90 seconds. Restore power and press the On/Off sensor firmly for 4 seconds until the hob performs self-calibration and beeps.
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F05 registered by the microcomputer controller. Pyrolytic door lock motor or latch switch timeout
On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: door lock motor failed to rotate or microswitch open Metrological tolerance verification: lock motor coil nominal 2.8 kΩ; switch 0.0 Ω..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure door lock motor resistance (expected ~2.8 kΩ) and test switch. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F05 indicates defrost heater circuit open circuit; defrost cycle aborted due to zero current draw.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Burnt calrod heating element, open bi-metal klixon safety thermostat (trips at +8°C), or blown thermal fuse (resistance: 220–380 Ω 230V).
Disconnect power. Measure resistance across defrost heater terminals (220–380 Ω). Test thermal fuse continuity (0 Ω). Replace defective heater or fuse harness. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F05 registered by the microcomputer controller. Drain pump blocked or pressure switch stuck on full state
On Scholtès appliances engineered with Arcadia 2 heavy-duty inverter drive with digital inductive pressure sensor, dynamic drum unbalance detection, and ceramic-coated heating element: drain pump impeller jammed by debris Metrological tolerance verification: drain pump coil nominal 165 Ω ± 7%..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure drain pump coil resistance (expected ~165 Ω) and inspect lint trap. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn selector knob to Reset/Cancel (or Off). Press and hold the Start/Pause button for 6 seconds until the drain pump runs momentarily and door lock clicks open, indicating clearing of fault code.
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F5 registered by the microcomputer controller. Ambient room temperature NTC sensor failure
On Scholtès appliances engineered with Dynamic Air Cooling airflow with multi-sensor evaporator defrost cycle, bi-stable refrigerant distribution valve, and high-efficiency hermetic compressor: ambient sensor on cabinet hinge cover open Metrological tolerance verification: nominal 2.7 kΩ at 25°C..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: test sensor continuity across hinge harness connector. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press the Holiday / Eco mode and Fast Freeze buttons simultaneously for 5 seconds until the display flashes twice and the audible alarm silences.
Scholtès Heat Pump Sensor Dry Tumble Dryer: Drum rotation tachometer pulse failure F06; motor runs but microcomputer receives no tachometric feedback within 5 seconds.
On Scholtès tumble dryers: Broken poly-V drive belt, loose motor shaft tachometer magnet, disconnected tach harness plug, or worn idler tension spring.
Inspect drum drive belt tension around motor spindle and drum perimeter. Measure tachometer generator coil resistance (nominal 115–170 Ω). Replace belt if broken. Switch selector to Stop, press and hold Start/Pause for 5 seconds to clear error memory, then power off for 1 minute.
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F06 registered by the microcomputer controller. Induction coil NTC thermistor shorted to chassis or ground
On Scholtès appliances engineered with Arcadia / E.G.O. high-frequency induction power modules with digital temperature monitoring across each inductor core, touch slider filtering, and dynamic phase balancing: thermistor wire pinched to chassis Metrological tolerance verification: resistance to earth < 100 Ω..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: test sensor isolation to chassis ground (> 20 MΩ). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Ensure all cookware is removed and glass is completely dry. Turn off mains isolator switch for 90 seconds. Restore power and press the On/Off sensor firmly for 4 seconds until the hob performs self-calibration and beeps.
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F06 registered by the microcomputer controller. Pyrolytic door unlock failure / latch switch stuck in lock position
On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: door latch mechanism mechanically jammed by thermal contraction Metrological tolerance verification: lock motor nominal 2.8 kΩ..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: inspect motor cam gear and check microswitch feedback. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F06 indicates inverter compressor driver module communication failure or locked rotor protection trip.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Blown IGBT bridge on inverter board, open phase winding on BLDC compressor (6–15 Ω across U-V, V-W, W-U), or loss of PWM control signal (50–150 Hz).
Disconnect power. Measure BLDC compressor phase-to-phase resistances (must be identical 6–15 Ω). Check 230V AC input to inverter and PWM signal from main board. Replace inverter board if motor is good. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F06 registered by the microcomputer controller. Program selector switch position contact defect
On Scholtès appliances engineered with Arcadia 2 heavy-duty inverter drive with digital inductive pressure sensor, dynamic drum unbalance detection, and ceramic-coated heating element: selector rotary switch contact open Metrological tolerance verification: selector contact resistance < 0.5 Ω across positions..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: test continuity of rotary selector contacts across each wash mode. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn selector knob to Reset/Cancel (or Off). Press and hold the Start/Pause button for 6 seconds until the drain pump runs momentarily and door lock clicks open, indicating clearing of fault code.
Scholtès Heat Pump Sensor Dry Tumble Dryer: Heating element relay contacts welded closed F07; power PCB senses continuous thermal draw when heating is commanded off.
On Scholtès tumble dryers: High current electrical arcing welding relay armature contacts on main control module under heavy 2500W load.
Disconnect power immediately to prevent overheating. Test normally-open relay contacts with ohmmeter (must read open circuit). Replace heater relay or PCB. Switch selector to Stop, press and hold Start/Pause for 5 seconds to clear error memory, then power off for 1 minute.
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F07 registered by the microcomputer controller. Induction filter board internal relay open / defective
On Scholtès appliances engineered with Arcadia / E.G.O. high-frequency induction power modules with digital temperature monitoring across each inductor core, touch slider filtering, and dynamic phase balancing: filter board relay coil open Metrological tolerance verification: relay coil resistance ~350 Ω..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure filter board relay coil resistance and inspect contacts. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Ensure all cookware is removed and glass is completely dry. Turn off mains isolator switch for 90 seconds. Restore power and press the On/Off sensor firmly for 4 seconds until the hob performs self-calibration and beeps.
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F07 registered by the microcomputer controller. Tangential cooling fan motor open or Hall tachometer failure (<700 RPM)
On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: tangential cooling turbine stalled or Hall sensor pulse missing Metrological tolerance verification: cooling fan coil resistance ~180 Ω..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure cooling fan motor winding resistance (expected ~180 Ω). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F07 indicates evaporator fan Hall-effect speed feedback pulse missing; fan runs in fail-safe mode.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Defective Hall sensor integrated circuit inside motor end bell, broken third feedback wire, or failed pull-up resistor on main board (12V DC line).
Disconnect power. Inspect fan harness for pin detachment. Measure DC voltage on feedback line while slowly spinning fan by hand (pulses between 0V and 5V DC). Replace fan motor if pulse is flat. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F07 registered by the microcomputer controller. Wash heating element relay open or heater element open circuit (~26 Ω)
On Scholtès appliances engineered with Arcadia 2 heavy-duty inverter drive with digital inductive pressure sensor, dynamic drum unbalance detection, and ceramic-coated heating element: wash heating element conductor broken Metrological tolerance verification: nominal 25.0 Ω to 28.0 Ω (2000W / 230V)..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure resistance across wash heating element pins (expected ~26 Ω). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn selector knob to Reset/Cancel (or Off). Press and hold the Start/Pause button for 6 seconds until the drain pump runs momentarily and door lock clicks open, indicating clearing of fault code.
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F7 registered by the microcomputer controller. Evaporator defrost heating element open circuit or thermal fuse blown
On Scholtès appliances engineered with Dynamic Air Cooling airflow with multi-sensor evaporator defrost cycle, bi-stable refrigerant distribution valve, and high-efficiency hermetic compressor: defrost heater wire broken Metrological tolerance verification: nominal 240 Ω to 280 Ω (220W / 230V)..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure defrost heater resistance across terminals (expected ~260 Ω). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press the Holiday / Eco mode and Fast Freeze buttons simultaneously for 5 seconds until the display flashes twice and the audible alarm silences.
Scholtès Heat Pump Sensor Dry Tumble Dryer: Heating element open circuit or heat pump compressor failure F08; air chamber temperature fails to rise by 5°C in 15 minutes.
On Scholtès tumble dryers: Broken nichrome coil on dual heating element (28 Ω + 36 Ω), tripped manual high-limit stat, or seized heat-pump compressor.
Check red reset button on rear heater casing. Measure resistance of both heating circuits (approx 28 Ω and 36 Ω). In heat pump units, verify compressor windings. Switch selector to Stop, press and hold Start/Pause for 5 seconds to clear error memory, then power off for 1 minute.
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F08 registered by the microcomputer controller. Auxiliary DC power supply rail out of tolerance (+5V/+12V rail drop)
On Scholtès appliances engineered with Arcadia / E.G.O. high-frequency induction power modules with digital temperature monitoring across each inductor core, touch slider filtering, and dynamic phase balancing: SMPS power supply circuit capacitor failed Metrological tolerance verification: secondary voltage +12.0V DC ± 5%..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure secondary DC voltages on power board test points. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Ensure all cookware is removed and glass is completely dry. Turn off mains isolator switch for 90 seconds. Restore power and press the On/Off sensor firmly for 4 seconds until the hob performs self-calibration and beeps.
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F08 registered by the microcomputer controller. Core temperature meat probe circuit open or shorted
On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: meat probe sensor wire broken or jack socket shorted Metrological tolerance verification: nominal 10 kΩ at 25°C or PT1000..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: test probe resistance across 3.5mm audio jack terminals. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F08 indicates condenser cooling fan motor circuit open or stalled; high condensing pressure and compressor thermal tripping.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Heavy lint blockage on condenser coil, motor winding open circuit (35–65 Ω), or blown triac/relay on power PCB (12V DC or 230V AC).
Disconnect power. Vacuum condenser coils and fan blades. Measure motor coil resistance (35–65 Ω). Test power supply voltage across harness (12V DC / 230V AC). Replace motor if open circuit. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F08 registered by the microcomputer controller. Wash heating element relay stuck closed or earth insulation leak
On Scholtès appliances engineered with Arcadia 2 heavy-duty inverter drive with digital inductive pressure sensor, dynamic drum unbalance detection, and ceramic-coated heating element: heater control relay contacts welded Metrological tolerance verification: continuity 0.0 Ω across open relay contacts..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: inspect relay contacts on power board with power off. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn selector knob to Reset/Cancel (or Off). Press and hold the Start/Pause button for 6 seconds until the drain pump runs momentarily and door lock clicks open, indicating clearing of fault code.
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F8 registered by the microcomputer controller. Defrost heater triac shorted / heater permanently powered
On Scholtès appliances engineered with Dynamic Air Cooling airflow with multi-sensor evaporator defrost cycle, bi-stable refrigerant distribution valve, and high-efficiency hermetic compressor: defrost heater triac shorted on power board Metrological tolerance verification: triac resistance 0.0 Ω shorted..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: test defrost heater drive triac on main control PCB. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press the Holiday / Eco mode and Fast Freeze buttons simultaneously for 5 seconds until the display flashes twice and the audible alarm silences.
Electronic Control Board (PCB) & Bus Communications
Scholtès Heat Pump Sensor Dry Tumble Dryer: Control board EEPROM configuration checksum error F09; processor detects corrupted model variant coding in memory.
On Scholtès tumble dryers: Voltage fluctuation during drying cycle write operation, lightning grid surge, or memory silicon degradation.
Unplug unit for 15 minutes. If code returns upon power-up, reconfigure board with brand service tool or replace pre-programmed electronic control module. Switch selector to Stop, press and hold Start/Pause for 5 seconds to clear error memory, then power off for 1 minute.
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F09 registered by the microcomputer controller. Communication loss between user display board and power PCB
On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: ribbon data cable damaged or loose Metrological tolerance verification: UART serial line 5V logic pulses..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: reseat communication ribbon cable between display and power board. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F09 indicates user interface (UI) display board communication timeout; control panel keys fail to respond.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Severed serial data wire in door hinge, water intrusion into dispenser PCB, or corrupted UART transceiver on main PCB (12V DC bus).
Disconnect power. Remove hinge cover and inspect harness for pinched conductors. Test 12.0V DC supply and 0.5–4.5V DC data pulse with multimeter. Repair wire or replace UI module. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.