Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code A1 registered by the microcomputer controller. Freezer compartment high temperature warning (> -9°C)
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code A2 registered by the microcomputer controller. Refrigerator compartment high temperature warning (> +10°C)
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès LTE / LPE Maxi Plate 14-Place Integrated Dishwasher: Diagnostic fault code A04 registered by the microcomputer controller. Wash water temperature sensor NTC open or short circuit
Scholtès LTE / LPE Maxi Plate 14-Place Integrated Dishwasher: Diagnostic fault code A06 registered by the microcomputer controller. Water fill timeout / flowmeter pulses missing or tap closed
Scholtès LTE / LPE Maxi Plate 14-Place Integrated Dishwasher: Diagnostic fault code A12 registered by the microcomputer controller. Communication loss between user interface and main board
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Alarm code AL04 indicates prolonged AC mains power outage; internal cabinet temperature rose above safe food storage threshold.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Status code CC indicates continuous cooling or fast freeze mode has run continuously for over 24 hours without cycling off.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code CI indicates ice maker harvest arm motor stalled; ejector blades jammed against ice cubes in mold.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Status notification dF indicates defrost cycle in progress; compressor and fan paused while calrod heater operates.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E1 registered by the microcomputer controller. Touch key panel obstructed / liquid spill or object over controls
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E5 registered by the microcomputer controller. Internal communication loss between touch UI and power generator module
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E6 registered by the microcomputer controller. Power module heatsink temperature sensor over-temperature (>95°C)
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E7 registered by the microcomputer controller. Induction coil temperature sensor NTC open or short circuit
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E9 registered by the microcomputer controller. User interface touch configuration checksum error
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code E9 indicates critical high temperature condition inside cabinet; perishable food at risk of spoiling.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic error ER CF indicates condenser cooling fan motor stall or feedback signal loss; compressor overheating danger.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code ER dS indicates defrost NTC thermistor open or short circuit; defrost cycle duration strictly time-limited.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code ER FF indicates freezer evaporator fan motor stalled or drawing excessive current; freezing performance lost.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code ER rF indicates fresh food compartment circulating fan motor stall; poor temperature distribution in refrigerator.
Scholtès Heat Pump Sensor Dry Tumble Dryer: Drum drive motor relay or triac failure F01; power PCB detects uncommanded drum rotation or shorted motor driver.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F01 registered by the microcomputer controller. Induction generator left rear zone IGBT driver fault
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F01 indicates fresh food compartment evaporator NTC sensor out of calibration or open circuit.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F01 registered by the microcomputer controller. Motor triac short-circuit / motor runaway protection
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F1 registered by the microcomputer controller. Refrigerator compartment air temperature NTC sensor failure
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F02 registered by the microcomputer controller. Induction generator left front zone IGBT driver fault
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F02 indicates freezer evaporator NTC sensor out of calibration or short-circuit detected.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F02 registered by the microcomputer controller. Motor tachometer generator open / no pulses received
Scholtès Heat Pump Sensor Dry Tumble Dryer: Front air duct NTC thermistor fault F03; process air temperature sensor signal detected open or shorted to chassis.
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F03 registered by the microcomputer controller. Induction generator right rear zone IGBT driver fault
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F03 registered by the microcomputer controller. Wash water temperature NTC sensor open or short circuit
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F3 registered by the microcomputer controller. Freezer compartment air temperature NTC sensor failure
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F04 registered by the microcomputer controller. Induction generator right front zone IGBT driver fault
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F04 indicates motorized air damper position sensor feedback switch open or shorted.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F04 registered by the microcomputer controller. Water level pressure switch stuck on empty state
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F05 registered by the microcomputer controller. Induction coil NTC thermistor disconnected or open circuit
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F05 indicates defrost heater circuit open circuit; defrost cycle aborted due to zero current draw.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F05 registered by the microcomputer controller. Drain pump blocked or pressure switch stuck on full state
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F5 registered by the microcomputer controller. Ambient room temperature NTC sensor failure
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F06 registered by the microcomputer controller. Induction coil NTC thermistor shorted to chassis or ground
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F06 registered by the microcomputer controller. Program selector switch position contact defect
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F07 registered by the microcomputer controller. Tangential cooling fan motor open or Hall tachometer failure (<700 RPM)
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F07 indicates evaporator fan Hall-effect speed feedback pulse missing; fan runs in fail-safe mode.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F07 registered by the microcomputer controller. Wash heating element relay open or heater element open circuit (~26 Ω)
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F7 registered by the microcomputer controller. Evaporator defrost heating element open circuit or thermal fuse blown
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Heat Pump Sensor Dry Tumble Dryer: Heating element open circuit or heat pump compressor failure F08; air chamber temperature fails to rise by 5°C in 15 minutes.
Immersion / Air Heating Element & Klixon Thermostat
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F08 registered by the microcomputer controller. Auxiliary DC power supply rail out of tolerance (+5V/+12V rail drop)
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F08 indicates condenser cooling fan motor circuit open or stalled; high condensing pressure and compressor thermal tripping.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F09 registered by the microcomputer controller. Communication loss between user display board and power PCB
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F09 indicates user interface (UI) display board communication timeout; control panel keys fail to respond.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F09 registered by the microcomputer controller. Main control board EEPROM setup checksum failure
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F9 registered by the microcomputer controller. Motorized air damper flap position sensor failure / flap stuck
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Electronic range control (ERC) EEPROM checksum fault F1 E0; oven display beeps continuously and disables all bake modes.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F10 registered by the microcomputer controller. Variable speed inverter compressor communication error
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F10 registered by the microcomputer controller. Pressure switch signal simultaneous empty and full (inconsistent)
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Scholtès Supreme Inox & Touch-Control Dishwasher: Main electronic control board relay malfunction F1 E1; dishwasher fails to execute wash cycles and beeps on power-up.
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Relay board microprocessor communication failure F1 E1; oven elements fail to energize and error tones sound.
Scholtès Heat Pump Sensor Dry Tumble Dryer: UI to main control board serial communication timeout F11; console display fails to synchronize packets with power board.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F11 registered by the microcomputer controller. Freezer evaporator brushless DC fan motor stalled / no tacho
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F1E1 indicates main electronic control board MCU microprocessor failure; internal relays fail to engage.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F12 registered by the microcomputer controller. User interface EEPROM data mismatch with power stage
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F12 registered by the microcomputer controller. Display board communication loss with main control board
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F13 registered by the microcomputer controller. Dryer NTC sensor open or short circuit (Washer-Dryer)
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F14 registered by the microcomputer controller. Dryer heating element open circuit (Washer-Dryer)
Scholtès Heat Pump Sensor Dry Tumble Dryer: Drum belt tensioner safety switch open F15; microswitch on motor jockey arm trips due to loose or broken drive belt.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F17 registered by the microcomputer controller. Door interlock delayed locking / PTC microswitch open
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Shorted keypad touch pad switch F2 E0; oven control registers a continuously depressed key and locks out panel.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Heat Pump Sensor Dry Tumble Dryer: Display to power module serial handshake loss F21; communication line fails periodic liveness heartbeat check.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F2E1 indicates communication loss between user interface display panel and main control board.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Supreme Inox & Touch-Control Dishwasher: User interface to electronic control board communication loss F2 E2; console display goes dark or flashes intermittently.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F2E2 registers user interface supply voltage abnormal; dispenser screen flickers or resets erratically.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F28 registered by the microcomputer controller. User interface display communication timeout with power board
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Supreme Inox & Touch-Control Dishwasher: Thermistor NTC water temperature sensor fault F3 E1; wash cycle runs excessively long or water fails to reach sanitize temp.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F3E1 indicates fresh food compartment (RC) NTC thermistor open or short circuit; cabinet temperature fluctuates wildly.
Scholtès Supreme Inox & Touch-Control Dishwasher: Wash water heating fault F3 E3; control board detects no temperature rise after 30 minutes of continuous wash operation.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F3E5 indicates freezer evaporator defrost thermistor open or out of limits; defrost heater fails to terminate correctly.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F4E1 indicates fresh food compartment evaporator fan motor stalled or disconnected; air circulation fails.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Supreme Inox & Touch-Control Dishwasher: Circulation wash motor drive triac fault F4 E2; wash pump motor fails to start or runs uncommanded at full speed.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F4E2 indicates freezer evaporator fan motor stall or tachometer feedback failure; freezer warms rapidly.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F4E4 indicates in-door ice box blower fan motor blocked or disconnected; ice melting in storage bin.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F47 registered by the microcomputer controller. LIN-bus communication error between touch display and power module
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F48 registered by the microcomputer controller. Induction zone booster power limiter jumper missing or invalid
Immersion / Air Heating Element & Klixon Thermostat
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F49 registered by the microcomputer controller. Capacitive touch controller I2C communication bus error
Immersion / Air Heating Element & Klixon Thermostat
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F5E1 indicates French door interlock switch or vertical mullion heater open; condensation forms on cabinet flange.
Immersion / Air Heating Element & Klixon Thermostat
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F5E2 indicates dispenser ice chute motorized flapper door failed to open or close; air leaks frost the chute.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F5E3 indicates motorized air damper door stuck open or closed; fresh food section either freezes or warms up.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F6E1 indicates serial communication timeout between main control board and door dispenser display.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F6E2 indicates communication loss between main power board and variable frequency inverter compressor driver.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F8E1 indicates primary water inlet solenoid valve electrical fault; water dispenser and ice maker starved of water.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F8E2 indicates ice maker fill valve flow meter timeout; insufficient water volume dosed into ice tray.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Status notification FB indicates water filter bypass plug is installed; water dispenser operating without active carbon filtration.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code H1 indicates critical over-temperature condition in freezer; compartment temperature rose above 0°C.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code H2 indicates fresh food compartment temperature elevated above +16°C; loss of refrigeration cooling capacity.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code H20 registered by the microcomputer controller. Water filling timeout / inlet valve or tap pressure failure
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code HC indicates high cabinet temperature warning; freezer compartment exceeded -5°C for longer than 60 minutes.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code L registered by the microcomputer controller. Child lock safety active / controls locked
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code LC indicates low temperature condition in fresh food compartment; fresh vegetables freezing on bottom crisper shelves.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Status notification OF indicates cooling off or showroom demo mode is active; display operates but cooling system is shut down.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code OV indicates inverter driver DC link over-voltage trip; compressor shut down to protect power semiconductors.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code P1 indicates delicatessen pantry drawer temperature sensor circuit open or shorted.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code PF indicates power failure event occurred; electronic control board clock reset and alarm flashes.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code SY CE indicates system communication error between user interface touch panel and main control board.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code SY EF indicates system evaporator fan circuit malfunction; zero rotational feedback detected by electronic control.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code U400 registered by the microcomputer controller. Voltage connection fault (400V 2-phase connected across single 230V rail)
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code 7E indicates external ambient temperature sensor analog channel error; control defaults to 22°C nominal room reference.
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F09 registered by the microcomputer controller. Main control board EEPROM setup checksum failure
On Scholtès appliances engineered with Arcadia 2 heavy-duty inverter drive with digital inductive pressure sensor, dynamic drum unbalance detection, and ceramic-coated heating element: memory byte corruption on main board Metrological tolerance verification: drain pump synchronous motor coil nominal 165 Ω to 180 Ω (230V AC).
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure drain pump coil resistance across terminals (expected ~170 Ω). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn selector knob to Reset/Cancel (or Off). Press and hold the Start/Pause button for 6 seconds until the drain pump runs momentarily and door lock clicks open, indicating clearing of fault code.
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F9 registered by the microcomputer controller. Motorized air damper flap position sensor failure / flap stuck
On Scholtès appliances engineered with Dynamic Air Cooling airflow with multi-sensor evaporator defrost cycle, bi-stable refrigerant distribution valve, and high-efficiency hermetic compressor: damper gear motor jammed Metrological tolerance verification: motor coil resistance ~250 Ω per phase..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure damper motor phase windings and test mechanical baffle travel. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press the Holiday / Eco mode and Fast Freeze buttons simultaneously for 5 seconds until the display flashes twice and the audible alarm silences.
Electronic Control Board (PCB) & Bus Communications
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Electronic range control (ERC) EEPROM checksum fault F1 E0; oven display beeps continuously and disables all bake modes.
On Scholtès ovens (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Power line voltage transients or spikes corrupted non-volatile memory registers inside the microprocessor.
Disconnect 240V power at home breaker panel for 2 minutes to reboot microcontroller. If code returns upon power restoration, replace electronic oven control (ERC) board. Touch and hold the Menu/Back sensor for 5 seconds, switch off the dedicated circuit breaker for 60 seconds, then reset time of day.
Scholtès Heat Pump Sensor Dry Tumble Dryer: Motor control module thermal cutoff activation F10; MCU inverter temperature exceeds safe operating threshold (> 85°C).
On Scholtès tumble dryers: Blocked lower air cooling intake vents, heavy lint accumulation over electronics heatsink, or bearing friction on motor shaft.
Clean base ventilation grilles. Vacuum lint from inverter heatsink fins. Check motor shaft for free spin without radial play. Allow unit to cool 30 minutes. Switch selector to Stop, press and hold Start/Pause for 5 seconds to clear error memory, then power off for 1 minute.
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F10 registered by the microcomputer controller. Heating element relay stuck closed (upper, lower, circular, or grill)
On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: relay contacts permanently closed under inductive load Metrological tolerance verification: continuity 0.0 Ω across open relay contacts..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: inspect relay contacts on power board with power off. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F10 registered by the microcomputer controller. Variable speed inverter compressor communication error
On Scholtès appliances engineered with Dynamic Air Cooling airflow with multi-sensor evaporator defrost cycle, bi-stable refrigerant distribution valve, and high-efficiency hermetic compressor: inverter communication wire loose Metrological tolerance verification: PWM control signal 5V logic pulses..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: check wiring harness between main control PCB and compressor inverter. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press the Holiday / Eco mode and Fast Freeze buttons simultaneously for 5 seconds until the display flashes twice and the audible alarm silences.
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F10 registered by the microcomputer controller. Pressure switch signal simultaneous empty and full (inconsistent)
On Scholtès appliances engineered with Arcadia 2 heavy-duty inverter drive with digital inductive pressure sensor, dynamic drum unbalance detection, and ceramic-coated heating element: pressure switch dual microswitches jammed Metrological tolerance verification: drain pump synchronous motor coil nominal 165 Ω to 180 Ω (230V AC).
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure drain pump coil resistance across terminals (expected ~170 Ω). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn selector knob to Reset/Cancel (or Off). Press and hold the Start/Pause button for 6 seconds until the drain pump runs momentarily and door lock clicks open, indicating clearing of fault code.
Scholtès Supreme Inox & Touch-Control Dishwasher: Main electronic control board relay malfunction F1 E1; dishwasher fails to execute wash cycles and beeps on power-up.
On Scholtès dishwashers (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Welded heater relay contacts, cracked solder joint on power traces, or corrupted firmware register in microcontroller.
Check line voltage at main board J1 connector (120V AC). Inspect relay contacts for continuity with power removed (infinite resistance normally open). Hold Start/Cancel pad for 5 seconds until drain initiates, allow 60s, then cycle mains power.
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Relay board microprocessor communication failure F1 E1; oven elements fail to energize and error tones sound.
On Scholtès ovens (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Internal hardware latchup on secondary relay board, burned relay coil, or broken ribbon communication cable to display.
Inspect power relay board connectors. Measure line supply to relay board (120V AC on L1/N). Test heating relay contact resistance (<0.5 Ω closed). Touch and hold the Menu/Back sensor for 5 seconds, switch off the dedicated circuit breaker for 60 seconds, then reset time of day.
Scholtès LTE / LPE Maxi Plate 14-Place Integrated Dishwasher: Diagnostic fault code F11 registered by the microcomputer controller. Scholtès: Washing cycle does not start, humming noise.
On Scholtès appliances engineered with EVO-3 / Arcadia hydraulic control platform with variable-frequency wash pump, active siphonage detection, and calibrated NTC immersion thermistor: Wash motor (circulation pump) is faulty or seized. Metrological tolerance verification: drain pump synchronous motor coil nominal 165 Ω to 180 Ω (230V AC).
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure drain pump coil resistance across terminals (expected ~170 Ω). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press and hold the P (Program) and Start buttons simultaneously for 4 seconds until all LEDs illuminate and the machine emits a beep, then turn selector to 0 to cancel the error.
Electronic Control Board (PCB) & Bus Communications
Scholtès Heat Pump Sensor Dry Tumble Dryer: UI to main control board serial communication timeout F11; console display fails to synchronize packets with power board.
On Scholtès tumble dryers: Loose 4-wire data harness between top console and rear power module, moisture ingress, or 5V DC supply rail drop.
Check wiring harness continuity and firmly seat connectors at both ends. Verify 5V DC and 12V DC test voltages on power PCB. Replace defective harness. Switch selector to Stop, press and hold Start/Pause for 5 seconds to clear error memory, then power off for 1 minute.
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F11 registered by the microcomputer controller. Pyrolytic safety thermostat open circuit / manual reset tripped
On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: safety thermostat tripped due to airflow restriction Metrological tolerance verification: manual reset thermostat continuity 0.0 Ω closed..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: press red manual reset button on safety thermostat and test continuity. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F11 registered by the microcomputer controller. Freezer evaporator brushless DC fan motor stalled / no tacho
On Scholtès appliances engineered with Dynamic Air Cooling airflow with multi-sensor evaporator defrost cycle, bi-stable refrigerant distribution valve, and high-efficiency hermetic compressor: fan blade blocked by ice accumulation Metrological tolerance verification: fan motor coil ~45 Ω or 12V BLDC driver..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: defrost evaporator housing and verify 12V DC power to fan motor. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press the Holiday / Eco mode and Fast Freeze buttons simultaneously for 5 seconds until the display flashes twice and the audible alarm silences.
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F11 registered by the microcomputer controller. Drain pump coil open circuit or triac driver damaged
On Scholtès appliances engineered with Arcadia 2 heavy-duty inverter drive with digital inductive pressure sensor, dynamic drum unbalance detection, and ceramic-coated heating element: drain pump coil wire open circuit Metrological tolerance verification: pump coil nominal 165 Ω ± 7%..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure drain pump coil resistance across terminals (expected ~165 Ω). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn selector knob to Reset/Cancel (or Off). Press and hold the Start/Pause button for 6 seconds until the drain pump runs momentarily and door lock clicks open, indicating clearing of fault code.
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F1E1 indicates main electronic control board MCU microprocessor failure; internal relays fail to engage.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Power supply surge, blown SMPS regulator, or corrupted internal flash memory on the 12V/5V DC rails.
Disconnect mains power (115V/230V AC). Inspect main PCB for scorched capacitors or damaged traces. Test 12V DC and 5V DC output rails with multimeter. Replace board if rails read 0V. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Supreme Inox & Touch-Control Dishwasher: Sub-processor flash memory checksum error F1 E2; display LEDs lock up and machine becomes unresponsive to keypad input.
On Scholtès dishwashers (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Corrupted internal microcode communications between main CPU and user interface peripheral coprocessor.
Disconnect power for 5 minutes. Inspect ribbon cable between main control and console for corrosion or moisture. Replace main control board if error recurs. Hold Start/Cancel pad for 5 seconds until drain initiates, allow 60s, then cycle mains power.
On Scholtès tumble dryers: Disconnected slip ring wiper contact on front drum baffle, broken sensor lead, or heavy calcium coating on sensing bars.
Clean sensor bars with fine sandpaper and vinegar. Inspect carbon brush slip contact riding on drum shell. Verify wiring continuity to electronic board. Switch selector to Stop, press and hold Start/Pause for 5 seconds to clear error memory, then power off for 1 minute.
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F12 registered by the microcomputer controller. User interface EEPROM data mismatch with power stage
On Scholtès appliances engineered with Arcadia / E.G.O. high-frequency induction power modules with digital temperature monitoring across each inductor core, touch slider filtering, and dynamic phase balancing: touch UI software incompatible with power inverter Metrological tolerance verification: nominal NTC thermistor 10.0 kΩ at 25°C, 32.0 kΩ at 0°C.
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure sensor resistance across probe pins (expected ~10 kΩ at 25°C). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Ensure all cookware is removed and glass is completely dry. Turn off mains isolator switch for 90 seconds. Restore power and press the On/Off sensor firmly for 4 seconds until the hob performs self-calibration and beeps.
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F12 registered by the microcomputer controller. Electronic board internal temperature exceeds 85°C
On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: cooling air duct blocked or cooling fan speed low Metrological tolerance verification: PCB NTC thermistor < 1.0 kΩ (>85°C)..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: clear upper ventilation intake slot and test tangential blower speed. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F12 registered by the microcomputer controller. Display board communication loss with main control board
On Scholtès appliances engineered with Arcadia 2 heavy-duty inverter drive with digital inductive pressure sensor, dynamic drum unbalance detection, and ceramic-coated heating element: serial bus cable damaged or disconnected Metrological tolerance verification: serial bus data line 5V logic pulses..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: inspect wiring harness connecting display and power modules. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn selector knob to Reset/Cancel (or Off). Press and hold the Start/Pause button for 6 seconds until the drain pump runs momentarily and door lock clicks open, indicating clearing of fault code.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Defective inverter IPM module, open 3-phase compressor windings, or loss of PWM signal (50–150 Hz) from main board.
Disconnect mains. Measure resistance across compressor pins U-V, V-W, U-W: each pair must read 6–15 Ω balanced. Check 120V/230V AC supply to inverter and 4–6V DC PWM signal. Replace inverter if windings test good. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Heat Pump Sensor Dry Tumble Dryer: Condenser heat exchanger NTC thermistor fault F13; evaporator temperature sensor value out of calibration range.
On Scholtès heat pump dryers: Wet lint clogged around heat pump evaporator fins, dislodged NTC clip on copper pipe, or sensor thermistor failure.
Clean heat exchanger fins with soft fin comb. Ensure NTC probe is firmly clipped to refrigerant tube. Measure resistance: nominal ~10 kΩ at 25°C. Switch selector to Stop, press and hold Start/Pause for 5 seconds to clear error memory, then power off for 1 minute.
On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: steam generator thermistor open Metrological tolerance verification: nominal 10.0 kΩ at 25°C, 1.2 kΩ at 90°C..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure boiler NTC sensor resistance across terminals. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F13 registered by the microcomputer controller. Dryer NTC sensor open or short circuit (Washer-Dryer)
On Scholtès appliances engineered with Arcadia 2 heavy-duty inverter drive with digital inductive pressure sensor, dynamic drum unbalance detection, and ceramic-coated heating element: condenser dryer NTC sensor open Metrological tolerance verification: nominal 20.0 kΩ at 20°C..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure dryer temperature sensor resistance. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn selector knob to Reset/Cancel (or Off). Press and hold the Start/Pause button for 6 seconds until the drain pump runs momentarily and door lock clicks open, indicating clearing of fault code.
On Scholtès heat pump tumble dryers: Refrigerant circuit pressure unbalance, shorted BLDC compressor stator winding, or failed inverter power module.
Allow 20 minutes for refrigerant pressure equalization. Measure compressor terminal resistances across all 3 phases (symmetrical ~8–14 Ω). Replace inverter or compressor. Switch selector to Stop, press and hold Start/Pause for 5 seconds to clear error memory, then power off for 1 minute.
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F14 registered by the microcomputer controller. Steam generator fill solenoid valve timeout / no water detected
On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: boiler water feed pump failed or water line airlocked Metrological tolerance verification: feed pump coil resistance ~120 Ω..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure water injection pump coil resistance and inspect water tank filter. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F14 registered by the microcomputer controller. Dryer heating element open circuit (Washer-Dryer)
On Scholtès appliances engineered with Arcadia 2 heavy-duty inverter drive with digital inductive pressure sensor, dynamic drum unbalance detection, and ceramic-coated heating element: drying heating element wire open Metrological tolerance verification: nominal 32.0 Ω to 38.0 Ω (1400W / 230V)..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure resistance across dryer heating element terminals. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn selector knob to Reset/Cancel (or Off). Press and hold the Start/Pause button for 6 seconds until the drain pump runs momentarily and door lock clicks open, indicating clearing of fault code.
Scholtès LTE / LPE Maxi Plate 14-Place Integrated Dishwasher: Diagnostic fault code F15 registered by the microcomputer controller. Virtual sensor wash water missing / circulation pump cavitating
On Scholtès appliances engineered with EVO-3 / Arcadia hydraulic control platform with variable-frequency wash pump, active siphonage detection, and calibrated NTC immersion thermistor: water level too low in sump causing pump cavitation Metrological tolerance verification: circulation pump motor current < 0.2A..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: inspect water fill volume and check circulation pump pressure. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press and hold the P (Program) and Start buttons simultaneously for 4 seconds until all LEDs illuminate and the machine emits a beep, then turn selector to 0 to cancel the error.
Scholtès Heat Pump Sensor Dry Tumble Dryer: Drum belt tensioner safety switch open F15; microswitch on motor jockey arm trips due to loose or broken drive belt.
On Scholtès tumble dryers: Snapped drive belt, dislocated belt tensioner jockey wheel, or defective safety cutoff switch on motor cradle.
Remove side panel and inspect belt path. Mount new elastic poly-V belt around motor pulley and drum. Test tensioner switch continuity (< 1 Ω closed). Switch selector to Stop, press and hold Start/Pause for 5 seconds to clear error memory, then power off for 1 minute.
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F15 registered by the microcomputer controller. Steam drain pump blocked or defective
On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: drain valve actuator seized with calcium deposits Metrological tolerance verification: drain valve motor nominal 3.2 kΩ..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: descale boiler drain channel and measure drain valve motor resistance. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.