Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code A1 registered by the microcomputer controller. Freezer compartment high temperature warning (> -9°C)
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code A2 registered by the microcomputer controller. Refrigerator compartment high temperature warning (> +10°C)
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès LTE / LPE Maxi Plate 14-Place Integrated Dishwasher: Diagnostic fault code A04 registered by the microcomputer controller. Wash water temperature sensor NTC open or short circuit
Scholtès LTE / LPE Maxi Plate 14-Place Integrated Dishwasher: Diagnostic fault code A06 registered by the microcomputer controller. Water fill timeout / flowmeter pulses missing or tap closed
Scholtès LTE / LPE Maxi Plate 14-Place Integrated Dishwasher: Diagnostic fault code A12 registered by the microcomputer controller. Communication loss between user interface and main board
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Alarm code AL04 indicates prolonged AC mains power outage; internal cabinet temperature rose above safe food storage threshold.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Status code CC indicates continuous cooling or fast freeze mode has run continuously for over 24 hours without cycling off.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code CI indicates ice maker harvest arm motor stalled; ejector blades jammed against ice cubes in mold.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Status notification dF indicates defrost cycle in progress; compressor and fan paused while calrod heater operates.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E1 registered by the microcomputer controller. Touch key panel obstructed / liquid spill or object over controls
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E5 registered by the microcomputer controller. Internal communication loss between touch UI and power generator module
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E6 registered by the microcomputer controller. Power module heatsink temperature sensor over-temperature (>95°C)
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E7 registered by the microcomputer controller. Induction coil temperature sensor NTC open or short circuit
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E9 registered by the microcomputer controller. User interface touch configuration checksum error
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code E9 indicates critical high temperature condition inside cabinet; perishable food at risk of spoiling.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic error ER CF indicates condenser cooling fan motor stall or feedback signal loss; compressor overheating danger.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code ER dS indicates defrost NTC thermistor open or short circuit; defrost cycle duration strictly time-limited.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code ER FF indicates freezer evaporator fan motor stalled or drawing excessive current; freezing performance lost.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code ER rF indicates fresh food compartment circulating fan motor stall; poor temperature distribution in refrigerator.
Scholtès Heat Pump Sensor Dry Tumble Dryer: Drum drive motor relay or triac failure F01; power PCB detects uncommanded drum rotation or shorted motor driver.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F01 registered by the microcomputer controller. Induction generator left rear zone IGBT driver fault
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F01 indicates fresh food compartment evaporator NTC sensor out of calibration or open circuit.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F01 registered by the microcomputer controller. Motor triac short-circuit / motor runaway protection
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F1 registered by the microcomputer controller. Refrigerator compartment air temperature NTC sensor failure
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F02 registered by the microcomputer controller. Induction generator left front zone IGBT driver fault
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F02 indicates freezer evaporator NTC sensor out of calibration or short-circuit detected.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F02 registered by the microcomputer controller. Motor tachometer generator open / no pulses received
Scholtès Heat Pump Sensor Dry Tumble Dryer: Front air duct NTC thermistor fault F03; process air temperature sensor signal detected open or shorted to chassis.
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F03 registered by the microcomputer controller. Induction generator right rear zone IGBT driver fault
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F03 registered by the microcomputer controller. Wash water temperature NTC sensor open or short circuit
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F3 registered by the microcomputer controller. Freezer compartment air temperature NTC sensor failure
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F04 registered by the microcomputer controller. Induction generator right front zone IGBT driver fault
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F04 indicates motorized air damper position sensor feedback switch open or shorted.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F04 registered by the microcomputer controller. Water level pressure switch stuck on empty state
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F05 registered by the microcomputer controller. Induction coil NTC thermistor disconnected or open circuit
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F05 indicates defrost heater circuit open circuit; defrost cycle aborted due to zero current draw.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F05 registered by the microcomputer controller. Drain pump blocked or pressure switch stuck on full state
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F5 registered by the microcomputer controller. Ambient room temperature NTC sensor failure
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F06 registered by the microcomputer controller. Induction coil NTC thermistor shorted to chassis or ground
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F06 registered by the microcomputer controller. Program selector switch position contact defect
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F07 registered by the microcomputer controller. Tangential cooling fan motor open or Hall tachometer failure (<700 RPM)
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F07 indicates evaporator fan Hall-effect speed feedback pulse missing; fan runs in fail-safe mode.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F07 registered by the microcomputer controller. Wash heating element relay open or heater element open circuit (~26 Ω)
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F7 registered by the microcomputer controller. Evaporator defrost heating element open circuit or thermal fuse blown
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Heat Pump Sensor Dry Tumble Dryer: Heating element open circuit or heat pump compressor failure F08; air chamber temperature fails to rise by 5°C in 15 minutes.
Immersion / Air Heating Element & Klixon Thermostat
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F08 registered by the microcomputer controller. Auxiliary DC power supply rail out of tolerance (+5V/+12V rail drop)
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F08 indicates condenser cooling fan motor circuit open or stalled; high condensing pressure and compressor thermal tripping.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F09 registered by the microcomputer controller. Communication loss between user display board and power PCB
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F09 indicates user interface (UI) display board communication timeout; control panel keys fail to respond.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F09 registered by the microcomputer controller. Main control board EEPROM setup checksum failure
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F9 registered by the microcomputer controller. Motorized air damper flap position sensor failure / flap stuck
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Electronic range control (ERC) EEPROM checksum fault F1 E0; oven display beeps continuously and disables all bake modes.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F10 registered by the microcomputer controller. Variable speed inverter compressor communication error
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F10 registered by the microcomputer controller. Pressure switch signal simultaneous empty and full (inconsistent)
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Scholtès Supreme Inox & Touch-Control Dishwasher: Main electronic control board relay malfunction F1 E1; dishwasher fails to execute wash cycles and beeps on power-up.
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Relay board microprocessor communication failure F1 E1; oven elements fail to energize and error tones sound.
Scholtès Heat Pump Sensor Dry Tumble Dryer: UI to main control board serial communication timeout F11; console display fails to synchronize packets with power board.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F11 registered by the microcomputer controller. Freezer evaporator brushless DC fan motor stalled / no tacho
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F1E1 indicates main electronic control board MCU microprocessor failure; internal relays fail to engage.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F12 registered by the microcomputer controller. User interface EEPROM data mismatch with power stage
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F12 registered by the microcomputer controller. Display board communication loss with main control board
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F13 registered by the microcomputer controller. Dryer NTC sensor open or short circuit (Washer-Dryer)
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F14 registered by the microcomputer controller. Dryer heating element open circuit (Washer-Dryer)
Scholtès Heat Pump Sensor Dry Tumble Dryer: Drum belt tensioner safety switch open F15; microswitch on motor jockey arm trips due to loose or broken drive belt.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F17 registered by the microcomputer controller. Door interlock delayed locking / PTC microswitch open
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Shorted keypad touch pad switch F2 E0; oven control registers a continuously depressed key and locks out panel.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Heat Pump Sensor Dry Tumble Dryer: Display to power module serial handshake loss F21; communication line fails periodic liveness heartbeat check.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F2E1 indicates communication loss between user interface display panel and main control board.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Supreme Inox & Touch-Control Dishwasher: User interface to electronic control board communication loss F2 E2; console display goes dark or flashes intermittently.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F2E2 registers user interface supply voltage abnormal; dispenser screen flickers or resets erratically.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F28 registered by the microcomputer controller. User interface display communication timeout with power board
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Supreme Inox & Touch-Control Dishwasher: Thermistor NTC water temperature sensor fault F3 E1; wash cycle runs excessively long or water fails to reach sanitize temp.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F3E1 indicates fresh food compartment (RC) NTC thermistor open or short circuit; cabinet temperature fluctuates wildly.
Scholtès Supreme Inox & Touch-Control Dishwasher: Wash water heating fault F3 E3; control board detects no temperature rise after 30 minutes of continuous wash operation.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F3E5 indicates freezer evaporator defrost thermistor open or out of limits; defrost heater fails to terminate correctly.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F4E1 indicates fresh food compartment evaporator fan motor stalled or disconnected; air circulation fails.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Supreme Inox & Touch-Control Dishwasher: Circulation wash motor drive triac fault F4 E2; wash pump motor fails to start or runs uncommanded at full speed.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F4E2 indicates freezer evaporator fan motor stall or tachometer feedback failure; freezer warms rapidly.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F4E4 indicates in-door ice box blower fan motor blocked or disconnected; ice melting in storage bin.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F47 registered by the microcomputer controller. LIN-bus communication error between touch display and power module
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F48 registered by the microcomputer controller. Induction zone booster power limiter jumper missing or invalid
Immersion / Air Heating Element & Klixon Thermostat
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F49 registered by the microcomputer controller. Capacitive touch controller I2C communication bus error
Immersion / Air Heating Element & Klixon Thermostat
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F5E1 indicates French door interlock switch or vertical mullion heater open; condensation forms on cabinet flange.
Immersion / Air Heating Element & Klixon Thermostat
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F5E2 indicates dispenser ice chute motorized flapper door failed to open or close; air leaks frost the chute.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F5E3 indicates motorized air damper door stuck open or closed; fresh food section either freezes or warms up.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F6E1 indicates serial communication timeout between main control board and door dispenser display.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F6E2 indicates communication loss between main power board and variable frequency inverter compressor driver.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F8E1 indicates primary water inlet solenoid valve electrical fault; water dispenser and ice maker starved of water.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F8E2 indicates ice maker fill valve flow meter timeout; insufficient water volume dosed into ice tray.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Status notification FB indicates water filter bypass plug is installed; water dispenser operating without active carbon filtration.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code H1 indicates critical over-temperature condition in freezer; compartment temperature rose above 0°C.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code H2 indicates fresh food compartment temperature elevated above +16°C; loss of refrigeration cooling capacity.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code H20 registered by the microcomputer controller. Water filling timeout / inlet valve or tap pressure failure
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code HC indicates high cabinet temperature warning; freezer compartment exceeded -5°C for longer than 60 minutes.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code L registered by the microcomputer controller. Child lock safety active / controls locked
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code LC indicates low temperature condition in fresh food compartment; fresh vegetables freezing on bottom crisper shelves.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Status notification OF indicates cooling off or showroom demo mode is active; display operates but cooling system is shut down.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code OV indicates inverter driver DC link over-voltage trip; compressor shut down to protect power semiconductors.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code P1 indicates delicatessen pantry drawer temperature sensor circuit open or shorted.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code PF indicates power failure event occurred; electronic control board clock reset and alarm flashes.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code SY CE indicates system communication error between user interface touch panel and main control board.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code SY EF indicates system evaporator fan circuit malfunction; zero rotational feedback detected by electronic control.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code U400 registered by the microcomputer controller. Voltage connection fault (400V 2-phase connected across single 230V rail)
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code 7E indicates external ambient temperature sensor analog channel error; control defaults to 22°C nominal room reference.
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F15 registered by the microcomputer controller. Dryer heater control triac/relay failure
On Scholtès appliances engineered with Arcadia 2 heavy-duty inverter drive with digital inductive pressure sensor, dynamic drum unbalance detection, and ceramic-coated heating element: drying heater relay contacts welded Metrological tolerance verification: relay contacts stuck 0.0 Ω closed..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: test dryer heater relay on power board for welded contacts. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn selector knob to Reset/Cancel (or Off). Press and hold the Start/Pause button for 6 seconds until the drain pump runs momentarily and door lock clicks open, indicating clearing of fault code.
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F16 registered by the microcomputer controller. Touch control optical panel keys locked / persistent contact (>15s)
On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: grease or moisture film over touch glass Metrological tolerance verification: nominal PT1000 platinum RTD sensor 1080 Ω at 20°C (1000 Ω at 0°C).
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure probe resistance across harness terminals (expected ~1080 Ω at 20°C). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F16 registered by the microcomputer controller. Top-loading drum lock position sensor Posistop fault
On Scholtès appliances engineered with Arcadia 2 heavy-duty inverter drive with digital inductive pressure sensor, dynamic drum unbalance detection, and ceramic-coated heating element: drum position Hall sensor or magnet missing Metrological tolerance verification: Hall sensor signal switches 0V to 5V DC..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: verify drum magnet alignment and test Hall sensor output. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn selector knob to Reset/Cancel (or Off). Press and hold the Start/Pause button for 6 seconds until the drain pump runs momentarily and door lock clicks open, indicating clearing of fault code.
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F17 registered by the microcomputer controller. Motorized rotisserie drive motor open circuit or jammed
On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: rotisserie drive motor coil open Metrological tolerance verification: motor winding nominal 4.5 kΩ..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: test rotisserie motor winding resistance and inspect spit drive coupling. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F17 registered by the microcomputer controller. Door interlock delayed locking / PTC microswitch open
On Scholtès appliances engineered with Arcadia 2 heavy-duty inverter drive with digital inductive pressure sensor, dynamic drum unbalance detection, and ceramic-coated heating element: door lock PTC element open circuit Metrological tolerance verification: nominal PTC resistance 800 Ω to 1200 Ω..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure door interlock terminals 1-3 with door closed (expected ~1000 Ω). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn selector knob to Reset/Cancel (or Off). Press and hold the Start/Pause button for 6 seconds until the drain pump runs momentarily and door lock clicks open, indicating clearing of fault code.
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F18 registered by the microcomputer controller. DSP motor inverter microcontroller internal software fault
On Scholtès appliances engineered with Arcadia 2 heavy-duty inverter drive with digital inductive pressure sensor, dynamic drum unbalance detection, and ceramic-coated heating element: inverter microcontroller crashed Metrological tolerance verification: DC link capacitor voltage 315V-325V DC..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: inspect motor inverter PCB and test power components. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn selector knob to Reset/Cancel (or Off). Press and hold the Start/Pause button for 6 seconds until the drain pump runs momentarily and door lock clicks open, indicating clearing of fault code.
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F18_OV registered by the microcomputer controller. Internal halogen cavity illumination circuit driver open circuit
On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: lighting step-down transformer or bulb open Metrological tolerance verification: lighting circuit nominal 12V AC/DC..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: test halogen bulb filament continuity and 12V output. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F19 registered by the microcomputer controller. Catalytic smoke elimination filter heater element open
On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: pyrolytic smoke eliminator heater open Metrological tolerance verification: heater element nominal 120 Ω ± 5%..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure catalytic smoke filter heater resistance. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.
Electronic Control Board (PCB) & Bus Communications
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Shorted keypad touch pad switch F2 E0; oven control registers a continuously depressed key and locks out panel.
On Scholtès ovens (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Conductive silver paste migration or grease contamination behind membrane switch matrix, holding contacts closed for >20 seconds.
Disconnect ribbon cable between touch glass membrane and control board. If beeping stops, replace touch glass keypad assembly. If short persists, replace board. Touch and hold the Menu/Back sensor for 5 seconds, switch off the dedicated circuit breaker for 60 seconds, then reset time of day.
Scholtès Heat Pump Sensor Dry Tumble Dryer: Upper lint filter air flow restriction F20; airflow thermistor senses thermal rise due to clogged door lint screen.
On Scholtès tumble dryers: Thick lint mat over fine mesh door screen, fabric softener film blocking air pores, or obstructed front duct throat.
Wash door lint filter under hot running water with mild dish soap to clear invisible films. Vacuum out the lower filter chute before resuming cycle. Switch selector to Stop, press and hold Start/Pause for 5 seconds to clear error memory, then power off for 1 minute.
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F20 registered by the microcomputer controller. High-limit auxiliary thermal cutout switch open circuit
On Scholtès appliances engineered with Galileo electronic architecture with high-density pyrolytic thermal barrier, PT500 probe feedback, Hall-effect cooling fan regulation, and bi-metallic motorized door latch: chassis safety thermostat tripped due to airflow blockage Metrological tolerance verification: thermal cutout continuity 0.0 Ω closed..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: test manual reset safety thermostat on upper chassis. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn temperature and function dials to 0. Switch off oven circuit breaker for 60 seconds. Restore power, touch and hold the Timer/Clock button for 4 seconds until '0:00' flashes and error code extinguishes.
Scholtès Supreme Inox & Touch-Control Dishwasher: Console keypad short or stuck key F2 E1; dishwasher beeps repeatedly and refuses to start cycle.
On Scholtès dishwashers (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Steam or water droplets seeped behind touch overlay, or a tactile switch deformed and stuck in closed position for >20 seconds.
Remove outer door panel. Disconnect keypad ribbon from control board. If beeping stops and board boots into diagnostic mode, replace console touch panel. Hold Start/Cancel pad for 5 seconds until drain initiates, allow 60s, then cycle mains power.
Electronic Control Board (PCB) & Bus Communications
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Keypad ribbon cable disconnected F2 E1; console display is lit but touch inputs are completely ignored.
On Scholtès ovens (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Flexible flat ribbon cable unseated from zero-insertion-force (ZIF) socket on electronic control board.
Release ZIF connector locking slider, clean ribbon gold contacts with isopropyl alcohol, reseat cable straight and fully, and lock connector collar. Touch and hold the Menu/Back sensor for 5 seconds, switch off the dedicated circuit breaker for 60 seconds, then reset time of day.
Scholtès Heat Pump Sensor Dry Tumble Dryer: Display to power module serial handshake loss F21; communication line fails periodic liveness heartbeat check.
On Scholtès tumble dryers: Vibration-induced fretting corrosion on console plug terminals, damaged data wire, or electromagnetic interference from motor.
Disconnect and reseat data ribbon cable. Apply electronic contact lubricant to connector pins. Verify grounding strap between motor and chassis. Switch selector to Stop, press and hold Start/Pause for 5 seconds to clear error memory, then power off for 1 minute.
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F2E1 indicates communication loss between user interface display panel and main control board.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Pinched ribbon harness inside top door hinge, corroded connector pins, or damaged UART bus driver chip.
Disconnect power. Remove top hinge cover and test continuity of all harness conductors. Measure 12V DC supply voltage between pins 1 and 2 at UI harness. Replace damaged door harness assembly. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Supreme Inox & Touch-Control Dishwasher: User interface to electronic control board communication loss F2 E2; console display goes dark or flashes intermittently.
On Scholtès dishwashers (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Pinched communication wire harness in inner door hinge area, oxidized gold-plated contact pins, or failed transceiver IC on UI board.
Inspect wiring harness across door hinge. Measure continuity (<0.5 Ω per conductor) and verify +5V DC and +13.5V DC supply lines to console. Hold Start/Cancel pad for 5 seconds until drain initiates, allow 60s, then cycle mains power.
On Scholtès heat pump dryers: Severely blocked bottom condenser filter choking airflow, slow evaporator blower fan, or micro-leak in R134a/R290 gas circuit.
Clean or replace lower foam condenser filter block. Vacuum aluminum heat exchanger fins. Verify secondary cooling fan operates freely during drying. Switch selector to Stop, press and hold Start/Pause for 5 seconds to clear error memory, then power off for 1 minute.
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F2E2 registers user interface supply voltage abnormal; dispenser screen flickers or resets erratically.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Supply rail dropped below 10.5V DC or spiked above 14.5V DC due to filter capacitor degradation on main PCB.
Isolate mains. Measure DC voltage at main board UI connector with digital voltmeter: nominal is 12.0V DC (±0.5V). If reading is under 10.5V DC under load, replace main power board. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Heat Pump Sensor Dry Tumble Dryer: Lower condenser filter blockage warning F23; differential pressure switch or temperature delta detects restricted air path.
On Scholtès tumble dryers: Compressed sponge filter saturated with damp lint in bottom plinth compartment, or warped filter frame allowing air bypass.
Open plinth door, pull out foam filter element, wash thoroughly under running water, squeeze dry with towel, and reinstall firmly into cassette housing. Switch selector to Stop, press and hold Start/Pause for 5 seconds to clear error memory, then power off for 1 minute.
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F2E3 signals user interface EEPROM memory checksum mismatch; dispenser locked in default state.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Power line surge corrupted non-volatile configuration memory bytes on the dispenser PCB.
Disconnect power for 2 minutes to force hard cold reboot. If error persists upon power restoration, remove dispenser trim and replace user interface control board assembly. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
On Scholtès tumble dryers: High ambient humidity during calibration check, dried-out electrolytic filtering capacitor on PCB, or defective operational amplifier IC.
Ventilate laundry room to lower ambient humidity below 70%. Ensure drum is completely empty and dry. Execute factory diagnostic self-calibration routine. Switch selector to Stop, press and hold Start/Pause for 5 seconds to clear error memory, then power off for 1 minute.
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F28 registered by the microcomputer controller. User interface display communication timeout with power board
On Scholtès appliances engineered with Dynamic Air Cooling airflow with multi-sensor evaporator defrost cycle, bi-stable refrigerant distribution valve, and high-efficiency hermetic compressor: display communication cable damaged Metrological tolerance verification: serial bus data line 5V logic pulses..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: inspect ribbon cable connecting touch display to main power board. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Press the Holiday / Eco mode and Fast Freeze buttons simultaneously for 5 seconds until the display flashes twice and the audible alarm silences.
Measure RTD sensor resistance at disconnect plug with ohmmeter: must measure nominal 1,080 Ω ±20 Ω at 20°C (70°F) or 1,650 Ω at 350°F (177°C). If infinite Ω, replace probe. Touch and hold the Menu/Back sensor for 5 seconds, switch off the dedicated circuit breaker for 60 seconds, then reset time of day.
Scholtès Supreme Inox & Touch-Control Dishwasher: Thermistor NTC water temperature sensor fault F3 E1; wash cycle runs excessively long or water fails to reach sanitize temp.
On Scholtès dishwashers (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): NTC sensor open circuit (>200 kΩ) or shorted (<500 Ω), defective optical water indicator (OWI) housing, or loose harness.
Unplug dishwasher. Measure NTC thermistor resistance on OWI sensor: nominal 46–52 kΩ at 20°C (68°F), 9.5–11.5 kΩ at 60°C (140°F). Replace OWI if out of range. Hold Start/Cancel pad for 5 seconds until drain initiates, allow 60s, then cycle mains power.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F3E1 indicates fresh food compartment (RC) NTC thermistor open or short circuit; cabinet temperature fluctuates wildly.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Defective sensor capsule, moisture intrusion in probe head, or pinched wires in cabinet wall. Nominal: 2.7 kΩ at 25°C, 7.9 kΩ at 0°C.
Disconnect power. Unclip RC thermistor housing on right liner wall. Measure resistance with digital ohmmeter: expect 2.5–8.2 kΩ depending on temperature. If open or shorted, install replacement NTC sensor with sealed heat-shrink butt splices. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Supreme Inox & Touch-Control Dishwasher: Optical Water Indicator (OWI) turbidity sensor calibration fault F3 E2; dishwasher cannot calculate soil level or optimize water usage.
On Scholtès dishwashers (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Hard water film coating the optical lens inside sump, calcium deposit blocking infrared phototransistor, or defective transmitter LED.
Clean optical lens face in sump with vinegar and soft cloth. Calibrate OWI in service diagnostic test cycle. Replace OWI sensor assembly if calibration fails. Hold Start/Cancel pad for 5 seconds until drain initiates, allow 60s, then cycle mains power.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F3E2 indicates freezer compartment (FC) NTC thermistor fault; compressor runs continuously or short-cycles.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Open circuit or resistance drift in freezer sensor capsule. Nominal calibration: 2.7 kΩ at 25°C, 23.3 kΩ at -18°C (0°F).
Disconnect power. Remove rear freezer back panel to access sensor. Measure resistance with digital multimeter: at -18°C expect 21–25 kΩ, at 0°C expect 7.5–8.5 kΩ. Replace sensor assembly if open circuit or reading infinite Ω. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Supreme Inox & Touch-Control Dishwasher: Wash water heating fault F3 E3; control board detects no temperature rise after 30 minutes of continuous wash operation.
On Scholtès dishwashers (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Open calrod heating element, tripped high-limit safety thermostat on tub underside, or defective heater control relay on main board.
Disconnect power. Measure heating element resistance with multimeter: nominal 10–30 Ω (typically 12–18 Ω). Check high-limit thermostat continuity (<0.5 Ω). Hold Start/Cancel pad for 5 seconds until drain initiates, allow 60s, then cycle mains power.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F3E3 indicates in-door ice box compartment thermistor failure; ice production halts or ice maker overheats.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Open circuit in ice box NTC probe or broken wire in French-door hinge harness. Calibration: 2.7 kΩ at 25°C, 14.5 kΩ at -10°C.
Disconnect power. Remove ice storage bucket and sensor cover. Measure resistance with digital meter: nominal is 13.5–15.5 kΩ at ice-making temperature (-10°C). Replace ice box sensor harness assembly. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F3E4 indicates fresh food evaporator defrost termination sensor error; dual-evaporator coils freeze into solid frost block.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Clipped-on defrost thermistor resistance drifted or open circuit. Calibration: 2.7 kΩ at 25°C, 7.9 kΩ at 0°C, termination at +10°C (4.8 kΩ).
Disconnect power. Remove fresh food rear shroud. Test resistance with multimeter in ice water bath (0°C): must read 7.7–8.1 kΩ. Replace clipped defrost thermistor and ensure secure thermal paste contact with copper tubing. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.