Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code A1 registered by the microcomputer controller. Freezer compartment high temperature warning (> -9°C)
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code A2 registered by the microcomputer controller. Refrigerator compartment high temperature warning (> +10°C)
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès LTE / LPE Maxi Plate 14-Place Integrated Dishwasher: Diagnostic fault code A04 registered by the microcomputer controller. Wash water temperature sensor NTC open or short circuit
Scholtès LTE / LPE Maxi Plate 14-Place Integrated Dishwasher: Diagnostic fault code A06 registered by the microcomputer controller. Water fill timeout / flowmeter pulses missing or tap closed
Scholtès LTE / LPE Maxi Plate 14-Place Integrated Dishwasher: Diagnostic fault code A12 registered by the microcomputer controller. Communication loss between user interface and main board
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Alarm code AL04 indicates prolonged AC mains power outage; internal cabinet temperature rose above safe food storage threshold.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Status code CC indicates continuous cooling or fast freeze mode has run continuously for over 24 hours without cycling off.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code CI indicates ice maker harvest arm motor stalled; ejector blades jammed against ice cubes in mold.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Status notification dF indicates defrost cycle in progress; compressor and fan paused while calrod heater operates.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E1 registered by the microcomputer controller. Touch key panel obstructed / liquid spill or object over controls
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E5 registered by the microcomputer controller. Internal communication loss between touch UI and power generator module
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E6 registered by the microcomputer controller. Power module heatsink temperature sensor over-temperature (>95°C)
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E7 registered by the microcomputer controller. Induction coil temperature sensor NTC open or short circuit
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code E9 registered by the microcomputer controller. User interface touch configuration checksum error
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code E9 indicates critical high temperature condition inside cabinet; perishable food at risk of spoiling.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic error ER CF indicates condenser cooling fan motor stall or feedback signal loss; compressor overheating danger.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code ER dS indicates defrost NTC thermistor open or short circuit; defrost cycle duration strictly time-limited.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code ER FF indicates freezer evaporator fan motor stalled or drawing excessive current; freezing performance lost.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code ER rF indicates fresh food compartment circulating fan motor stall; poor temperature distribution in refrigerator.
Scholtès Heat Pump Sensor Dry Tumble Dryer: Drum drive motor relay or triac failure F01; power PCB detects uncommanded drum rotation or shorted motor driver.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F01 registered by the microcomputer controller. Induction generator left rear zone IGBT driver fault
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F01 indicates fresh food compartment evaporator NTC sensor out of calibration or open circuit.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F01 registered by the microcomputer controller. Motor triac short-circuit / motor runaway protection
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F1 registered by the microcomputer controller. Refrigerator compartment air temperature NTC sensor failure
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F02 registered by the microcomputer controller. Induction generator left front zone IGBT driver fault
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F02 indicates freezer evaporator NTC sensor out of calibration or short-circuit detected.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F02 registered by the microcomputer controller. Motor tachometer generator open / no pulses received
Scholtès Heat Pump Sensor Dry Tumble Dryer: Front air duct NTC thermistor fault F03; process air temperature sensor signal detected open or shorted to chassis.
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F03 registered by the microcomputer controller. Induction generator right rear zone IGBT driver fault
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F03 registered by the microcomputer controller. Wash water temperature NTC sensor open or short circuit
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F3 registered by the microcomputer controller. Freezer compartment air temperature NTC sensor failure
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F04 registered by the microcomputer controller. Induction generator right front zone IGBT driver fault
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F04 indicates motorized air damper position sensor feedback switch open or shorted.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F04 registered by the microcomputer controller. Water level pressure switch stuck on empty state
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F05 registered by the microcomputer controller. Induction coil NTC thermistor disconnected or open circuit
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F05 indicates defrost heater circuit open circuit; defrost cycle aborted due to zero current draw.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F05 registered by the microcomputer controller. Drain pump blocked or pressure switch stuck on full state
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F5 registered by the microcomputer controller. Ambient room temperature NTC sensor failure
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F06 registered by the microcomputer controller. Induction coil NTC thermistor shorted to chassis or ground
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F06 registered by the microcomputer controller. Program selector switch position contact defect
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F07 registered by the microcomputer controller. Tangential cooling fan motor open or Hall tachometer failure (<700 RPM)
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F07 indicates evaporator fan Hall-effect speed feedback pulse missing; fan runs in fail-safe mode.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F07 registered by the microcomputer controller. Wash heating element relay open or heater element open circuit (~26 Ω)
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F7 registered by the microcomputer controller. Evaporator defrost heating element open circuit or thermal fuse blown
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Heat Pump Sensor Dry Tumble Dryer: Heating element open circuit or heat pump compressor failure F08; air chamber temperature fails to rise by 5°C in 15 minutes.
Immersion / Air Heating Element & Klixon Thermostat
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F08 registered by the microcomputer controller. Auxiliary DC power supply rail out of tolerance (+5V/+12V rail drop)
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F08 indicates condenser cooling fan motor circuit open or stalled; high condensing pressure and compressor thermal tripping.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Galileo / Multi-Oven / S-Line Pyrolytic Built-in Oven: Diagnostic fault code F09 registered by the microcomputer controller. Communication loss between user display board and power PCB
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F09 indicates user interface (UI) display board communication timeout; control panel keys fail to respond.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F09 registered by the microcomputer controller. Main control board EEPROM setup checksum failure
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F9 registered by the microcomputer controller. Motorized air damper flap position sensor failure / flap stuck
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Electronic range control (ERC) EEPROM checksum fault F1 E0; oven display beeps continuously and disables all bake modes.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F10 registered by the microcomputer controller. Variable speed inverter compressor communication error
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F10 registered by the microcomputer controller. Pressure switch signal simultaneous empty and full (inconsistent)
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Scholtès Supreme Inox & Touch-Control Dishwasher: Main electronic control board relay malfunction F1 E1; dishwasher fails to execute wash cycles and beeps on power-up.
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Relay board microprocessor communication failure F1 E1; oven elements fail to energize and error tones sound.
Scholtès Heat Pump Sensor Dry Tumble Dryer: UI to main control board serial communication timeout F11; console display fails to synchronize packets with power board.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F11 registered by the microcomputer controller. Freezer evaporator brushless DC fan motor stalled / no tacho
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F1E1 indicates main electronic control board MCU microprocessor failure; internal relays fail to engage.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F12 registered by the microcomputer controller. User interface EEPROM data mismatch with power stage
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F12 registered by the microcomputer controller. Display board communication loss with main control board
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F13 registered by the microcomputer controller. Dryer NTC sensor open or short circuit (Washer-Dryer)
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F14 registered by the microcomputer controller. Dryer heating element open circuit (Washer-Dryer)
Scholtès Heat Pump Sensor Dry Tumble Dryer: Drum belt tensioner safety switch open F15; microswitch on motor jockey arm trips due to loose or broken drive belt.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code F17 registered by the microcomputer controller. Door interlock delayed locking / PTC microswitch open
Scholtès TFT Touch Screen Multi-Zone Pyrolytic Oven: Shorted keypad touch pad switch F2 E0; oven control registers a continuously depressed key and locks out panel.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Heat Pump Sensor Dry Tumble Dryer: Display to power module serial handshake loss F21; communication line fails periodic liveness heartbeat check.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F2E1 indicates communication loss between user interface display panel and main control board.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Supreme Inox & Touch-Control Dishwasher: User interface to electronic control board communication loss F2 E2; console display goes dark or flashes intermittently.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F2E2 registers user interface supply voltage abnormal; dispenser screen flickers or resets erratically.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Dynamic Air Cooling & Total No-Frost Built-in Refrigerator: Diagnostic fault code F28 registered by the microcomputer controller. User interface display communication timeout with power board
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Supreme Inox & Touch-Control Dishwasher: Thermistor NTC water temperature sensor fault F3 E1; wash cycle runs excessively long or water fails to reach sanitize temp.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F3E1 indicates fresh food compartment (RC) NTC thermistor open or short circuit; cabinet temperature fluctuates wildly.
Scholtès Supreme Inox & Touch-Control Dishwasher: Wash water heating fault F3 E3; control board detects no temperature rise after 30 minutes of continuous wash operation.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F3E5 indicates freezer evaporator defrost thermistor open or out of limits; defrost heater fails to terminate correctly.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F4E1 indicates fresh food compartment evaporator fan motor stalled or disconnected; air circulation fails.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Supreme Inox & Touch-Control Dishwasher: Circulation wash motor drive triac fault F4 E2; wash pump motor fails to start or runs uncommanded at full speed.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F4E2 indicates freezer evaporator fan motor stall or tachometer feedback failure; freezer warms rapidly.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F4E4 indicates in-door ice box blower fan motor blocked or disconnected; ice melting in storage bin.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F47 registered by the microcomputer controller. LIN-bus communication error between touch display and power module
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F48 registered by the microcomputer controller. Induction zone booster power limiter jumper missing or invalid
Immersion / Air Heating Element & Klixon Thermostat
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F49 registered by the microcomputer controller. Capacitive touch controller I2C communication bus error
Immersion / Air Heating Element & Klixon Thermostat
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F5E1 indicates French door interlock switch or vertical mullion heater open; condensation forms on cabinet flange.
Immersion / Air Heating Element & Klixon Thermostat
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F5E2 indicates dispenser ice chute motorized flapper door failed to open or close; air leaks frost the chute.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F5E3 indicates motorized air damper door stuck open or closed; fresh food section either freezes or warms up.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F6E1 indicates serial communication timeout between main control board and door dispenser display.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F6E2 indicates communication loss between main power board and variable frequency inverter compressor driver.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F8E1 indicates primary water inlet solenoid valve electrical fault; water dispenser and ice maker starved of water.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F8E2 indicates ice maker fill valve flow meter timeout; insufficient water volume dosed into ice tray.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Status notification FB indicates water filter bypass plug is installed; water dispenser operating without active carbon filtration.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code H1 indicates critical over-temperature condition in freezer; compartment temperature rose above 0°C.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code H2 indicates fresh food compartment temperature elevated above +16°C; loss of refrigeration cooling capacity.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code H20 registered by the microcomputer controller. Water filling timeout / inlet valve or tap pressure failure
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code HC indicates high cabinet temperature warning; freezer compartment exceeded -5°C for longer than 60 minutes.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code L registered by the microcomputer controller. Child lock safety active / controls locked
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code LC indicates low temperature condition in fresh food compartment; fresh vegetables freezing on bottom crisper shelves.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Status notification OF indicates cooling off or showroom demo mode is active; display operates but cooling system is shut down.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code OV indicates inverter driver DC link over-voltage trip; compressor shut down to protect power semiconductors.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code P1 indicates delicatessen pantry drawer temperature sensor circuit open or shorted.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code PF indicates power failure event occurred; electronic control board clock reset and alarm flashes.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code SY CE indicates system communication error between user interface touch panel and main control board.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code SY EF indicates system evaporator fan circuit malfunction; zero rotational feedback detected by electronic control.
Compressor Motor Windings (Run/Start) & Defrost Heater
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code U400 registered by the microcomputer controller. Voltage connection fault (400V 2-phase connected across single 230V rail)
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code 7E indicates external ambient temperature sensor analog channel error; control defaults to 22°C nominal room reference.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F3E5 indicates freezer evaporator defrost thermistor open or out of limits; defrost heater fails to terminate correctly.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Degraded NTC thermistor clipped to top evaporator return bend. Resistance spec: 2.7 kΩ at 25°C, 23.3 kΩ at -18°C, 7.9 kΩ at 0°C.
Disconnect power. Remove freezer evaporator cover. Measure resistance with digital ohmmeter across sensor leads: if reading is infinite or below 1.0 kΩ, clip on new OEM defrost sensor and seal wiring. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F3E6 registers pantry delicatessen drawer temperature sensor fault; custom temperature drawer cooling fails.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Pantry drawer NTC thermistor lead severed by drawer rail mechanism or internal probe open. Calibration: 2.7 kΩ at 25°C, 7.9 kΩ at 0°C.
Disconnect power. Slide out pantry drawer and inspect wiring harness along glide rails. Measure probe resistance with multimeter: expect 2.5–8.0 kΩ. Replace damaged pantry harness and thermistor module. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Supreme Inox & Touch-Control Dishwasher: Anti-flood base pan float switch stuck up F4 E1; wash cycle aborts and drain pump runs constantly to prevent floor overflow.
On Scholtès dishwashers (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Water leak accumulated in bottom drip tray, polystyrene float disk wedged under bracket, or microswitch contacts shorted.
Isolate electrical supply. Remove lower access kickplate and sponge out water from bottom pan. Free float disk and measure switch continuity: 0 Ω when down, infinite Ω when lifted. Hold Start/Cancel pad for 5 seconds until drain initiates, allow 60s, then cycle mains power.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F4E1 indicates fresh food compartment evaporator fan motor stalled or disconnected; air circulation fails.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): BLDC fan motor iced up, open stator windings (15–35 Ω), or loss of 12V DC power from main board.
Disconnect power. Remove evaporator cover panel. Verify fan blade spins freely without ice friction. Measure voltage at motor plug: expect 12.0V DC. If 12V present but motor will not spin, replace BLDC evaporator fan motor. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Supreme Inox & Touch-Control Dishwasher: Circulation wash motor drive triac fault F4 E2; wash pump motor fails to start or runs uncommanded at full speed.
On Scholtès dishwashers (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Power triac on main control board punched through by inductive spike, or shorted snubber network on motor drive circuit.
Inspect main board triac for thermal discoloration or blistering. Verify motor winding insulation to ground (>10 MΩ). Replace main control board if triac is shorted. Hold Start/Cancel pad for 5 seconds until drain initiates, allow 60s, then cycle mains power.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F4E2 indicates freezer evaporator fan motor stall or tachometer feedback failure; freezer warms rapidly.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Ice accumulation jamming impeller, burnt motor windings, or broken feedback wire in harness. Internal motor resistance: 20–45 Ω.
Disconnect power. Remove rear freezer back wall. Inspect fan shroud for frost buildup. Measure 12V DC supply and feedback frequency. If frozen, perform manual steam defrost; replace motor if coil reads open circuit. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Supreme Inox & Touch-Control Dishwasher: Circulation wash pump motor failure F4 E3; wash arms fail to rotate, leaving dishes soiled and detergent cup unwashed.
On Scholtès dishwashers (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Broken or jammed food chopper blade, glass shards blocking circulation impeller, or open BLDC 3-phase motor stator winding.
Inspect sump cavity and stainless steel chopper blade for debris. Measure wash motor stator winding resistance phase-to-phase: nominal 7–14 Ω balanced across all 3 phases. Hold Start/Cancel pad for 5 seconds until drain initiates, allow 60s, then cycle mains power.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F4E3 indicates machine compartment condenser cooling fan failure; compressor overheats and trips thermal protector.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Lint and pet hair obstructing fan shroud, seized motor bearings, or open 12V DC/120V AC motor winding. Coil resistance: 25–65 Ω.
Disconnect power. Remove rear lower service access panel. Vacuum condenser coils and clear lint from fan shroud. Check supply voltage (12V DC or 120V/230V AC depending on model). If voltage present and blade is clean, replace condenser fan motor. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F4E4 indicates in-door ice box blower fan motor blocked or disconnected; ice melting in storage bin.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Ice slush freeze-up around miniature blower wheel or open BLDC stator coil. Resistance: 15–40 Ω. Supply: 12V DC.
Disconnect power. Remove ice maker assembly and air duct cover. Defrost ice duct with warm air. Measure 12V DC on red/black wires during test mode. If 12V present but motor stalls, replace ice box fan motor assembly. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Electronic Control Board (PCB) & Bus Communications
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F47 registered by the microcomputer controller. LIN-bus communication error between touch display and power module
On Scholtès appliances engineered with Arcadia / E.G.O. high-frequency induction power modules with digital temperature monitoring across each inductor core, touch slider filtering, and dynamic phase balancing: LIN transceiver communication timeout Metrological tolerance verification: LIN bus idle 12V DC; active data pulses..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: check wiring continuity and test LIN transceiver IC. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Ensure all cookware is removed and glass is completely dry. Turn off mains isolator switch for 90 seconds. Restore power and press the On/Off sensor firmly for 4 seconds until the hob performs self-calibration and beeps.
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F48 registered by the microcomputer controller. Induction zone booster power limiter jumper missing or invalid
On Scholtès appliances engineered with Arcadia / E.G.O. high-frequency induction power modules with digital temperature monitoring across each inductor core, touch slider filtering, and dynamic phase balancing: power management coding resistor open Metrological tolerance verification: coding resistor nominal 4.7 kΩ..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: check power sharing configuration jumper on filter PCB. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Ensure all cookware is removed and glass is completely dry. Turn off mains isolator switch for 90 seconds. Restore power and press the On/Off sensor firmly for 4 seconds until the hob performs self-calibration and beeps.
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code F49 registered by the microcomputer controller. Capacitive touch controller I2C communication bus error
On Scholtès appliances engineered with Arcadia / E.G.O. high-frequency induction power modules with digital temperature monitoring across each inductor core, touch slider filtering, and dynamic phase balancing: I2C clock or data pull-up resistor fault Metrological tolerance verification: I2C bus resting 5.0V DC logic level..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure I2C clock and data line voltages on touch board. Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Ensure all cookware is removed and glass is completely dry. Turn off mains isolator switch for 90 seconds. Restore power and press the On/Off sensor firmly for 4 seconds until the hob performs self-calibration and beeps.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F5E1 indicates French door interlock switch or vertical mullion heater open; condensation forms on cabinet flange.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Defective magnetic reed switch in liner top or burned foil heater inside hinged mullion flap. Heater resistance: 70–120 Ω (115V) or 220–350 Ω (230V).
Disconnect power. Check door reed switch operation with magnet and multimeter continuity. Disconnect 2-pin mullion connector at bottom hinge: measure heater resistance (must be 70–350 Ω). Replace vertical mullion assembly if open circuit. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F5E2 indicates dispenser ice chute motorized flapper door failed to open or close; air leaks frost the chute.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Stripped gears in stepper drive motor, broken return spring, or open motor coil. Stepper winding resistance: 200–450 Ω.
Disconnect power. Remove dispenser facade. Inspect ice chute flapper for mechanical ice obstruction. Measure coil resistance of stepper motor: expect 200–450 Ω across phases. Replace motorized door actuator assembly if gears are stripped. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F5E3 indicates motorized air damper door stuck open or closed; fresh food section either freezes or warms up.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Ice accumulation jamming damper door, stripped stepper reduction gears, or open drive coils (200–400 Ω per phase, 12V DC).
Disconnect power. Remove air tower assembly at top center of fresh food liner. Test resistance across stepper motor pins: expect 200–400 Ω between pin pairs. Defrost duct if iced. Replace motorized damper assembly if motor does not cycle. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Electronic Control Board (PCB) & Bus Communications
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F6E1 indicates serial communication timeout between main control board and door dispenser display.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Oxidized Molex terminal pins at lower or upper door hinge connector, or failed serial buffer transceiver. Line voltage: 5V DC / 12V DC.
Disconnect mains power. Unplug hinge connectors, spray with electrical contact cleaner, and re-seat firmly. Verify 5V DC serial data line with oscilloscope or digital meter. Replace hinge wire harness if broken conductors found. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F6E2 indicates communication loss between main power board and variable frequency inverter compressor driver.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Disconnected 2-wire serial PWM harness between boards or failed optocoupler isolator on inverter board. Control signal: 4–6V DC PWM (50–150 Hz).
Disconnect power. Remove rear mechanical cover. Inspect 2-wire control harness between main board and inverter box. Measure PWM control voltage (4–6V DC fluctuating). If harness is good and voltage present, replace compressor inverter board. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F7E1 indicates freezer evaporator defrost heater or bi-metal thermal fuse open circuit; evaporator completely blocks with frost.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Burnt calrod heating element, open bi-metal safety cutoff thermostat (trips at 77°C), or defective defrost control relay. Resistance: 25–45 Ω (115V) or 220–380 Ω (230V).
Disconnect power. Remove freezer evaporator panel. Measure resistance across defrost heater terminals: must read 25–45 Ω (115V) or 220–380 Ω (230V). Check bi-metal thermostat for 0.0 Ω continuity when cold. Replace open heating element or thermal fuse. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F8E1 indicates primary water inlet solenoid valve electrical fault; water dispenser and ice maker starved of water.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Open solenoid coil, limescale-clogged internal pilot armature, or supply pressure under 1.4 bar (20 PSI). Coil resistance: 180–260 Ω (115V) or 3.5–4.5 kΩ (230V).
Disconnect power and turn off water supply. Access valve in machine compartment. Measure solenoid coil resistance: must read 180–260 Ω (115V) or 3.5–4.5 kΩ (230V). Verify mains pressure is 1.4–8.3 bar. Replace dual water valve assembly if coil reads open circuit. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F8E2 indicates ice maker fill valve flow meter timeout; insufficient water volume dosed into ice tray.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Restricted water filter cartridge, clogged fill tube, or defective reed switch flow meter generating less than 10 pulses/second. Filter pressure drop: > 2.0 bar.
Inspect and replace inline water filter if older than 6 months. Check fill tube above ice maker for freeze-up; thaw with hot air if blocked. Test flow meter pulses on multimeter Hz range (nominal 15–35 Hz during fill). Replace flow meter manifold if pulses absent. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F9E1 indicates ice maker harvest drive motor stalled or optical emitter-receiver beam blocked; harvest cycle fails.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Ice cube stuck in ejector blades, stripped drive gear, failed optics board, or open motor coil (3.5–5.0 kΩ, 115V/230V AC).
Disconnect power. Clear stuck ice cubes with warm water. Test infrared receiver LED diagnostics (2 pulses indicate normal, steady on indicates beam broken). Measure motor coil resistance (3.5–5.0 kΩ). Replace ice maker module if motor is open. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code F9E2 indicates ice maker mold release heater failure; ejector blades stall attempting to harvest unreleased cubes.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Open circuit in mold bottom calrod heater or blown internal thermal fuse. Heater resistance: 65–95 Ω (115V) or 250–380 Ω (230V).
Disconnect power. Disassemble front cover of ice maker. Measure mold heater resistance across test points L and H: expect 65–95 Ω (115V) or 250–380 Ω (230V). If circuit reads infinite Ω, replace ice maker assembly. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Status notification FB indicates water filter bypass plug is installed; water dispenser operating without active carbon filtration.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Water filter cartridge removed and bypass plug engaged, or filter head microswitch stuck closed (12V DC circuit).
Install genuine replacement water filter cartridge and rotate clockwise 90° until fully seated. Flush 3 liters of water through dispenser to clear air and reset indicator. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code H1 indicates critical over-temperature condition in freezer; compartment temperature rose above 0°C.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Compressor locked rotor, thermal protector trip, refrigerant leak, or door left open overnight (R600a charge 45–65 g).
Inspect door closure. Verify if compressor starts: measure winding resistance (6–15 Ω BLDC or 12–25 Ω AC). Check start relay and run capacitor (3–5 µF). Replace compressor if locked. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code H2 indicates fresh food compartment temperature elevated above +16°C; loss of refrigeration cooling capacity.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Motorized air damper stuck closed, frozen evaporator air ducts, stalled fresh food circulating fan, or capillary tube restriction.
Disconnect power. Inspect motorized air damper: test stepper coils (200–400 Ω). Check if circulating fan spins freely (12V DC). Defrost blocked air duct if iced. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès MLXE / SLW Supreme Care Integrated Washer-Dryer: Diagnostic fault code H20 registered by the microcomputer controller. Water filling timeout / inlet valve or tap pressure failure
On Scholtès appliances engineered with Arcadia 2 heavy-duty inverter drive with digital inductive pressure sensor, dynamic drum unbalance detection, and ceramic-coated heating element: inlet valve coil open or tap shut off Metrological tolerance verification: inlet valve coil nominal 3.8 kΩ..
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure resistance across inlet solenoid valve terminals (expected ~3.8 kΩ). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Turn selector knob to Reset/Cancel (or Off). Press and hold the Start/Pause button for 6 seconds until the drain pump runs momentarily and door lock clicks open, indicating clearing of fault code.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code HC indicates high cabinet temperature warning; freezer compartment exceeded -5°C for longer than 60 minutes.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Heavy warm food loading, defective door magnetic gasket, or slow refrigerant leak (R600a charge 45–65 g).
Check door seal closure with paper slip test. Clean condenser coils. Verify compressor current draw (0.4–0.9 A at 230V AC). If problem persists, test sealed system pressures. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.
Scholtès Induction Touch Control & S-Line Direct Slider Cooktop: Diagnostic fault code L registered by the microcomputer controller. Child lock safety active / controls locked
On Scholtès appliances engineered with Arcadia / E.G.O. high-frequency induction power modules with digital temperature monitoring across each inductor core, touch slider filtering, and dynamic phase balancing: child safety lock engaged in software Metrological tolerance verification: nominal NTC thermistor 10.0 kΩ at 25°C, 32.0 kΩ at 0°C.
Disconnect mains power before servicing. Unplug the harness at the main PCB and use a calibrated digital multimeter: measure sensor resistance across probe pins (expected ~10 kΩ at 25°C). Inspect contacts for pin oxidation or loose terminals. Replace defective part if out of tolerance, re-energize and clear error: Ensure all cookware is removed and glass is completely dry. Turn off mains isolator switch for 90 seconds. Restore power and press the On/Off sensor firmly for 4 seconds until the hob performs self-calibration and beeps.
Scholtès Pure Cold Built-in Total NoFrost Refrigerator: Diagnostic code LC indicates low temperature condition in fresh food compartment; fresh vegetables freezing on bottom crisper shelves.
On Scholtès refrigerators (Scholtès Haute Horlogerie Culinaire sensors and micro-electronic platform architecture): Motorized air damper baffle stuck wide open, drifting RC thermistor (falsely reading high Ω), or shorted damper triac on PCB.
Disconnect power. Remove air duct cover and inspect damper baffle. Measure stepper motor coils (200–400 Ω). Measure fresh food NTC resistance (7.9 kΩ at 0°C). Replace stuck damper. Press and hold Alarm Reset pad for 5 seconds, verify compartment display stops blinking, and allow 12h for complete stabilization.