Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
Candy • Central Diagnostic Dictionary
167 Verified Codes in Database

Candy Error Codes & Diagnostics

Access our premium database of error codes, common faults, and professional repair solutions for Candy appliances.

Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum

Candy — Complete OEM Fault Code Matrix & Reference Table

Official diagnostic reference matrix of Candy error codes, symptom descriptions, and verified technical inspection points.

167 / 167 results
Official diagnostic reference matrix of Candy error codes, symptom descriptions, and verified technical inspection points.
CodeAppliancesSymptom / Fault DescriptionPrimary Component / Test PointAction
AL01Refrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Critical freezer high temperature alarm AL01; freezer compartment temperature has risen above safe threshold of -9°C.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
AL02Refrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Water dispenser filter expiration / flow timeout alarm AL02; water purification filter cartridge life limit or fill slow rate detected.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
AL03Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Drain evacuation alarm AL03; sump fails to empty completely during intermediate rinse drain phase.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
AL05Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Water filling timeout alarm AL05; wash tank does not fill to operating level within program timeout limit.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
CLrWashing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Tub clean safety drain prompt CLr; automated maintenance rinse cycle or reminder to clean drum interior.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E0Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Touch control module initialization error E0; touch interface microcontroller fails internal RAM diagnostic self-test.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E0Refrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Interface display communication error E0; temperature control panel loses serial link with master power PCB.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
E01Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Water fill solenoid valve circuit fault E01; power board detects open circuit across inlet solenoid coil.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E01Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Airflow restriction warning E01; door lint filter clogged or lower heat exchanger condenser obstructed with lint.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E01Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Door interlock error E01; appliance refuses to commence wash cycle because the door latch contact is not verified.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E1Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Water inlet fill failure E1; appliance detects no incoming water flow into sump after opening fill valve.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E1Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Touch sensor zone covered by object or liquid E1; continuous conductive activation detected on control glass for >10 seconds.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E1Refrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Refrigerator compartment temperature sensor fault E1; fresh food section thermistor circuit open or shorted.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
E1Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Water drainage failure E1; machine unable to drain water from wash tub within 4 minutes.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E02Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Fill meter pulse count error E02; turbine sensor signals water fill but pulse frequency is erratic or dropping out.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E02Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Process air duct NTC sensor error E02; thermistor signal indicates circuit open, short, or temperature out of operating range.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E02Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Water inlet fill timeout E02; tub does not reach the minimum operating water level within 210 seconds of valve energization.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
E2Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Water fill timeout E2; flowmeter turbine pulse rate below threshold (<10 impulses per 100ml) during wash chamber filling.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E2Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Induction cooking zone coil overheat E2; NTC temperature sensor beneath ceramic glass detects temperature exceeding 240°C.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E2Refrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Freezer compartment temperature sensor malfunction E2; low-temperature NTC thermistor circuit open or short-circuited.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
E2Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Door / lid lock failure E2; machine does not engage lock solenoid or detects door open during cycle start.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E03Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Drain pump evacuation timeout E03; water remains detected in sump chamber after drain cycle timer elapses.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E03Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Maximum drying cycle time exceeded E03; machine aborts cycle after running for 210 minutes without laundry reaching target dryness.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E03Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Water evacuation fault E03; machine aborts cycle with water remaining in drum after 180 seconds of drain pump operation.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E3Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Drain evacuation timeout E3; water remains in sump after 240 seconds of drain pump operation.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E3Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Induction power board IGBT heatsink overtemperature E3; power transistor heatsink temperature exceeds 95°C safety shutoff.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E3Refrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Evaporator defrost temperature sensor fault E3; defrost termination NTC thermistor out of calibrated ohmic range.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
E3Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Spin cycle unbalance alert E3; drum cannot distribute wet laundry load evenly to reach high spin speeds safely.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E04Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Bottom tray anti-flood switch activated E04; water detected in base pan, triggering continuous drain and lock-out.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E04Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Heating circuit safety lockout E04; heater relay contacts stuck closed, or high-limit safety thermostat tripped.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E04Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Anti-flood safety trigger E04; electronic controller detects excessive water column level or floor leak sensor switch closure.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
E4Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Anti-flood leak protection triggered E4; float switch in the bottom chassis pan rises and engages emergency drain.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E4Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Induction coil temperature sensor circuit fault E4; coil center NTC thermistor reads open circuit or shorted.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E4Refrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Ambient room temperature sensor error E4; external cabinet thermistor circuit disconnected or shorted.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
E4Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Water fill timeout E4; water does not reach target level within 8 minutes of starting fill cycle.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E05Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Water temperature sensor measurement anomaly E05; NTC probe signal resistance indicates temperature below -5°C or above 90°C.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E05Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Heat pump compressor thermistor fault E05; suction / discharge pipe NTC sensor value out of operational specifications.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E05Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Wash temperature NTC sensor fault E05; electronic module reads temperature values outside nominal limits (-10°C to +105°C).

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E5Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Wash water temperature NTC sensor error E5; thermistor reading open-circuit or short-circuit outside allowable range.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E5Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Mains supply overvoltage fault E5; input AC voltage exceeds safe operating limit (>275V AC).

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E5Refrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Convertible zone temperature sensor fault E5; MyZone / Flex drawer thermistor sensing circuit failed.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
E06Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Main control board EEPROM verification fault E06; checksum register error halts cycle initialization.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E06Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Drum motor drive failure E06; motor hums but fails to rotate the drum, or drive motor trips on thermal overload.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E06Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Drum unbalance / microcomputer checksum error E06; spin ramp aborts repeatedly or main PCB parameter memory fails verification.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E6Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Controller EEPROM memory error E6; microcomputer detects corrupted configuration checksum or unprogrammed module.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E6Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Mains supply undervoltage fault E6; input AC voltage drops below operational threshold (<170V AC).

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E6Refrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Humidity sensor communication error E6; crisper drawer moisture and relative humidity module signal loss.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
E07Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Circulation wash pump motor rotation error E07; tachometer sensor sends no pulse feedback to power inverter.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E07Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Drum rotation sensor speed feedback missing E07; controller does not detect drum movement during program run.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E07Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Motor drive tachometer fault E07; drum does not rotate or motor starts at uncontrolled high speed then immediately stops.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E7Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Wash circulation pump failure E7; motor does not rotate, tachometer feedback is absent, or run capacitor is open.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E7Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Cooling fan failure E7; internal induction generator cooling fan motor stalled, disconnected, or zero RPM feedback.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E7Refrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Automatic ice maker mold temperature sensor error E7; ice tray thermistor reading out of bounds during freezing cycle.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
E7Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Motor drive inverter module overcurrent E7; drive electronics trip on thermal overload or excessive current draw.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E08Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Flow-through heater circuit open E08; water temperature does not increase during heated wash stage.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E08Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Rear heater safety Klixon thermostat open E08; high-limit thermal switch interrupts power to heater assembly.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E08Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Motor overspeed burst detected E08; speed feedback frequency spikes abnormally during initial tumble wash sequence.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E8Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Wash heating circuit failure E8; water fails to heat up, or high-limit safety thermostat opens.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E8Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Pan detection circuit error E8; coil cannot establish electromagnetic coupling or detects non-ferrous cookware.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E8Refrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Automatic ice maker ejection motor stall E8; ice tray harvest mechanism fails to complete home position cycle within 3 minutes.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
E09Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Drum motor drive semiconductor failure E09; motor triac shorted or direction reversing relay contacts burned on control PCB.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E09Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Motor drive electronic fault E09; power board detects shorted motor triac or inverter IGBT phase breakdown.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E9Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Turbidity optical sensor fault E9; infrared soil sensing system fails calibration during pre-wash evaluation.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E9Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Internal bus communication failure E9; touch control panel loses data communication with induction power module.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E9Refrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: High temperature warming warning E9; fresh food compartment temperature exceeds +12°C continuously for over 2 hours.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
E10Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Water diverter valve timeout E10; motorized spray arm alternator disc fails to reach requested position microswitch contact.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E10Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Moisture sensing conductivity circuit error E10; sensor bars in door opening read open circuit or shorted to chassis ground.

PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose
E10Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Program selector / drum position sensor error E10; dial input signal unrecognized or top-loader drum positioning sensor missing.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E11Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Exhaust air temperature overheat E11; air temperature leaving the drum exceeds 80°C triggering thermal protection.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E11Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Washer-dryer drying heating fault E11; air heating duct fails to reach temperature or dryer thermistor open circuit.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E12Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Software sequence logic fault E12; program execution controller detects an illegal cycle state or memory jump.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E12Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Serial communication timeout E12; display console fails to exchange data telegrams with main chassis power board.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E12Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Washer-dryer ventilation error E12; air circulation blower motor stall or drying auxiliary controller communication loss.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E13Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Condensate collection container full alert E13; water reservoir float switch trips and halts program execution.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E13Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Bus communication fault E13; user interface display panel loses serial handshake with main chassis power board.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E14Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Flowmeter signal missing during fill E14; pressure switch senses water rising in tub but zero flowmeter impulses arrive at PCB.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
E14Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Condensate lift pump motor fault E14; pump fails to lift water from bottom collector to upper reservoir.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E14Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Wash water heating failure E14; water temperature does not rise after 20 minutes of active wash program operation.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E15Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Spray arm rotation / water pressure discrepancy E15; dynamic wash hydraulic pressure falls below operational threshold.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
E15Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Inverter compressor driver fault E15; heat-pump variable speed compressor trips on overcurrent or locked rotor protection.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E15Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Microcontroller memory failure E15; main control module detects an invalid EEPROM checksum or unconfigured firmware parameter.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E16Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Water softener regeneration valve fault E16; salt chamber regeneration solenoid open-circuit or shorted on power board.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E16Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Heat pump evaporator coil freezing alert E16; evaporator temperature drops below -5°C during active drying cycle.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E16Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Heating element earth insulation leak E16; appliance trips residual current device (RCD / breaker) or detects stray current to chassis ground.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E17Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: High water inlet flow / pressure fault E17; flowmeter impeller velocity exceeds maximum rate (>15 bar surge).

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E17Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Drum drive belt breakage detected E17; tensioner pulley safety microswitch opens when belt tension is lost.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E17Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Motor speed signal frequency anomaly E17; tachometer pulse cadence does not match inverter drive excitation frequency.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E18Dishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Low water level during circulation E18; circulation wash pump sucks air pockets causing cavitation and pressure loss.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
E18Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Power supply voltage or frequency fault E18; AC mains input deviates outside allowable 190V–255V operating window.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E18Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: AC mains power supply out of limits E18; voltage fluctuates outside 185V–260V AC or frequency deviates from 50/60 Hz.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E20Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Electronic pressure sensor calibration fault E20; signal frequency received from the analog pressure transducer is out of valid bounds.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
E21Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Moisture sensing calibration amplifier fault E21; analog-to-digital converter receives out-of-scale conductance baseline.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E21Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Water level sensor drift E21; water column pressure rises unexpectedly while solenoid inlet valves are de-energized.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
E22Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Siphoning drain detection E22; water level drops continuously during active wash fill cycle without pump activation.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
EARefrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Condenser tube temperature sensor error EA; discharge line thermistor reading indicates abnormal thermal overload.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
EdDishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Detergent dispenser actuator fault Ed; tablet door flap fails to trip open during primary wash cycle.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
EdRefrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Defrost heating circuit failure Ed; evaporator defrost heater fails to terminate cycle within programmed maximum runtime.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
EFDishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Flowmeter pulse overflow anomaly EF; impulse count exceeds maximum safety tank volume during filling phase.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
EFRefrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Evaporator fan rotor stall / hardware trip EF; fan motor overcurrent detected by motor driver circuitry.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
EhDishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Heating circuit safety thermal overheat Eh; water temperature sensor detects temperature exceeding 85°C.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
ELDishwasher

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Low incoming water pressure detected EL; flowmeter pulse cadence indicates line pressure under 0.5 bar.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
ErRefrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Electronic controller EEPROM checksum error Er; microcontroller fails internal data validation checksum on power-up.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
Er01Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Cavity temperature sensor open circuit Er01; electronic controller reads infinite resistance from the PT500 / PT1000 oven probe.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
Er02Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Cavity temperature sensor short circuit Er02; measured resistance across probe terminals drops below 100 Ω threshold.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
Er03Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Cavity overtemperature condition Er03; cavity temperature exceeds 320°C in standard baking or 520°C in pyrolytic clean mode.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
ER03Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Permanent touch key activation alarm ER03; liquid spill or cookware resting continuously on sensor controls.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
Er04Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Tangential cooling fan failure Er04; electronics cooling blower tachometer signal absent or speed falls below minimum RPM.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
Er05Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Pyrolysis door lock latch failure Er05; motorized latch mechanism fails to engage door interlock within 60 seconds of cycle start.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
Er06Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Pyrolysis door unlock timeout Er06; motorized latch mechanism fails to retract after cavity cools below safe temperature (~250°C).

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
Er07Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Food meat probe circuit fault Er07; internal core thermometer probe reads short-circuited or out-of-scale temperature.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
Er08Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Power relay board communication lost Er08; display interface loses serial handshake with heating element relay power module.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
Er09Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Stuck touch control key error Er09; capacitive glass touch pad detects continuous activation for longer than 30 seconds.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
Er15Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Electronics housing ambient overtemperature Er15; control board internal thermal sensor detects temperature exceeding 85°C.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
Er20Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Microcontroller flash memory checksum fault Er20; internal processor ROM memory block verification fails at boot.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
ER20Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Microcontroller flash / EEPROM checksum error ER20; induction power board parameter registers corrupted.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
Er21Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Low-voltage DC power supply ripple fault Er21; 5V DC or 12V DC power bus voltage drops below operating threshold.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
ER21Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Ambient electronics housing temperature exceeded ER21; internal temperature inside cooktop enclosure exceeds 85°C.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
Er22Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Touch control panel matrix evaluation error Er22; touch controller detects invalid internal scanning line pattern.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
ER22Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Touch control evaluation hardware fault ER22; capacitive sensing integrated circuit detects an internal analog front-end failure.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
Er31Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Appliance variant model configuration error Er31; EEPROM parameters do not match installed hardware options (rotisserie, pyro, steam).

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
ER31Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Power board configuration data corrupted ER31; generator module variant coding table does not match cooktop model setup.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
Er36Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Display console temperature sensor fault Er36; on-board thermistor on user interface board reads out of range.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
ER36Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Touch board ambient NTC sensor shorted ER36; temperature sensor on user interface PCB reads short-circuit to ground.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
Er47Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: LIN-bus communication error Er47; internal local interconnect network link between touch interface and power module drops packets.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
ER47Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: LIN-Bus communication between touch controller and power inverter module missing ER47; transmission timeout error.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
Er56Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Analog-to-digital converter reference error Er56; microprocessor ADC reference voltage drifts outside ±2% precision limits.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
F0Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Cooking coil temperature sensor disconnected F0; generator board detects open circuit on temperature feedback line.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
F0Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: User interface board communication failure F0; display module cannot communicate with main power relay board.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
F0Refrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Variable frequency inverter compressor communication fault F0; main control PCB loses PWM / UART handshake with inverter driver board.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
F1Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Air intake temperature sensor fault F1; front air temperature probe disconnected or reading outside allowable bounds.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
F1Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Cooking coil temperature sensor short circuit F1; measured probe resistance drops to near zero ohms.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
F1Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Temperature sensor disconnected F1; cavity sensor circuit is open, preventing oven heating operation.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
F1Refrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Freezer evaporator fan motor malfunction F1; low-voltage brushless DC circulation fan stalled or tachometer feedback missing.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
F2Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Rear exhaust temperature sensor fault F2; exhaust air probe sends corrupted or out-of-range temperature signal.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
F2Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Communication loss to induction generator module F2; main controller loses sync with left or right power inverter board.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
F2Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Cavity overtemperature safety shutoff F2; oven temperature exceeds maximum safety limit during heating cycle.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
F2Refrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Refrigerator compartment air circulation fan fault F2; fresh food multi-airflow fan fails rotation speed verification.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
F3Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Compressor discharge pipe high-temperature limit exceeded F3; temperature on discharge line exceeds 115°C.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
F3Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Temperature sensor probe circuit open F3; sensor signal resistance is infinite, halting heating cycle.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
F3Refrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Condenser cooling fan motor failure F3; rear machine compartment fan stalls or fails thermal heat extraction.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
F3Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Wash water temperature NTC sensor error F3; temperature readings open or short-circuited.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
F4Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Condensate evacuation pump failure F4; water level switch in collection sump remains active after pump run cycle.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
F4Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Temperature sensor probe short circuit F4; sensor signal resistance is near zero ohms, preventing temperature control.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
F4Refrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Inverter module IPM overcurrent / compressor lockout F4; compressor driver detects abnormal rotor stall or power transistor overload.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
F4Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Heating circuit failure F4; water does not heat up during wash phase within allotted cycle time.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
F5Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Motor / compressor inverter communication timeout F5; main PCB loses data link with drive inverter module.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
F5Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Cooling fan hall sensor feedback missing F5; electronics cooling fan is commanded on but speed sensor sends zero RPM.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
F5Refrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Motorized air damper baffle malfunction F5; motorized cold air shutter fails to reach calibrated open or closed position.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
F6Tumble Dryer

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Auxiliary heat-pump cooling fan fault F6; compressor compartment ventilation fan motor stalled or disconnected.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
F6Refrigerator

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Refrigerant switching valve error F6; bistable 3-way solenoid valve fails to direct refrigerant between fridge and freezer circuits.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
F7Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Mains supply frequency out of limits F7; AC power line frequency falls outside 47 Hz–63 Hz operating window.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
F7Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Stuck touch key / keypad matrix line shorted F7; button input is registered as permanently pressed.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
F7Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Motor drive board communication / synchronization fault F7; inverter driver board fails to command motor rotation.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
F8Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Continuous heating safety timer shutoff F8; cooking zone automatically powers off after exceeding maximum continuous runtime limit.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
F8Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Meat probe temperature limit exceeded F8; core probe signal indicates temperature above maximum safe reading.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
F9Hob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Induction coil current sensor calibration failure F9; current transformer sensing circuit fails zero-offset balance test at power up.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
F9Oven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Motorized door latch switch timing error F9; latch motor runs but lock switch does not transition within expected time window.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
FAWashing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Water level frequency sensor abnormal FA; water level reading absent or outside valid frequency bounds (~20–40 kHz).

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
FC0Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Inverter drive communication loss FC0; main control module loses communication handshake with motor inverter module.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
FC1Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Display board communication timeout FC1; user interface touch panel fails to synchronize with system controller.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
FC2Washing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: EEPROM variant configuration parameter mismatch FC2; model code programming does not match installed chassis hardware.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
LHob

Candy Induction Hob touch panel shows 'L' on all zone displays and control keys do not respond to touch.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
LocOven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Child safety lock active Loc; control panel keypad inputs are locked to prevent accidental burner/oven activation.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
SabbOven

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Sabbath mode operating status Sabb; steady-state heating enabled, display tones silenced, and door switches disabled.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
STOPOven

STOP message displayed, often during pyrolytic cleaning

PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose
UHob

Candy Moderna / Idea / Smart Touch Induction Cooktop: Mains supply undervoltage / phase missing alert U; cooktop detects open circuit on secondary phase or voltage under 170V AC.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
UnbWashing Machine

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Unbalanced load notification Unb; appliance pauses spin ramp and attempts automatic load redistribution.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose

Candy — Known Error Codes

CodeAppliancesFault / DiagnosticsRepair InstructionsAction
E20
Washing Machine
Water Level Pressure Switch & Air Dome

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Electronic pressure sensor calibration fault E20; signal frequency received from the analog pressure transducer is out of valid bounds.

On Candy washing machines powered by Speed-Drive Inverter brushless motor, Smart Touch NFC / hOn Wi-Fi connectivity, and GIAS Cuore electronic platform: Blocked pressure tube, punctured silicone diaphragm, or defective oscillator in electronic pressure switch (~25.6 kHz empty).

Inspect rubber pressure hose for pinholes or splits. Blow through tube towards tub to clear compression dome. Measure sensor output frequency (~25.6 kHz empty). Turn dial to Off, press and hold Start/Pause and Extra Rinse simultaneously for 5 seconds until display flashes '888', then power cycle.

Diagnose
E21
Tumble Dryer
General System & Mechanical Integration

Candy RapidÓ / Smart Pro Heat-Pump & Condenser Dryer: Moisture sensing calibration amplifier fault E21; analog-to-digital converter receives out-of-scale conductance baseline.

On Candy tumble dryers utilizing RapidÓ heat-pump thermodynamic circuit, 7-sensor electronic moisture tracking, and hOn remote diagnostics: Wet conductive fluff bridging sensor strips to chassis, moisture inside front fascia harness, or operational amplifier IC drift.

Thoroughly vacuum lint from sensor bar mounting insulator. Check resistance between sensor strips and chassis (must be infinite >20 MΩ when dry). Switch selector to Off, press and hold Start and Delay Start together for 5 seconds until buzzer beeps twice, then turn to 12 o'clock.

Diagnose
E21
Washing Machine
Water Level Pressure Switch & Air Dome

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Water level sensor drift E21; water column pressure rises unexpectedly while solenoid inlet valves are de-energized.

On Candy washing machines featuring Speed-Drive Inverter brushless motor, Smart Touch NFC / hOn Wi-Fi connectivity, and GIAS Cuore electronic platform: Mechanically weeping solenoid valve diaphragm allowing slow drip, or moisture condensation inside the pressure switch transducer.

Turn off water tap overnight to verify if tub collects water (confirms weeping valve; replace valve). Inspect pressure switch tubing for water droplets. Turn dial to Off, press and hold Start/Pause and Extra Rinse simultaneously for 5 seconds until display flashes '888', then power cycle.

Diagnose
E22
Washing Machine
Water Level Pressure Switch & Air Dome

Candy RapidÓ / Smart Pro / GrandÓ Vita Inverter Washer: Siphoning drain detection E22; water level drops continuously during active wash fill cycle without pump activation.

On Candy washing machines featuring Speed-Drive Inverter brushless motor, Smart Touch NFC / hOn Wi-Fi connectivity, and GIAS Cuore electronic platform: Drain hose installed too low (<65 cm height), drain hose pushed too far into standpipe creating airtight siphon seal.

Ensure top of drain hose bend is suspended between 65 cm and 100 cm above floor level. Use anti-siphon curved elbow and provide air gap in standpipe. Turn dial to Off, press and hold Start/Pause and Extra Rinse simultaneously for 5 seconds until display flashes '888', then power cycle.

Diagnose
EA
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Condenser tube temperature sensor error EA; discharge line thermistor reading indicates abnormal thermal overload.

On Candy refrigeration units featuring Fresco Total No-Frost dual-circulation cooling, multi-sensor temperature regulation, and inverter compressor: Blocked condenser air intake, failed condenser cooling fan, or drifted discharge thermistor resistance.

Clean rear air grilles and condenser mesh. Check condenser NTC sensor resistance (~5 kΩ at 25°C). Ensure minimum 5 cm clearance from rear wall. Reset: Press and hold Temp Set and Super Cool buttons together for 8 seconds until the display chime signals memory clear, then release.

Diagnose
Ed
Dishwasher
Drainage System & Drain Pump

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Detergent dispenser actuator fault Ed; tablet door flap fails to trip open during primary wash cycle.

On Candy dishwashers powered by Brava high-pressure wash hydraulics, Maxi Tub basket architecture, and Smart Touch / hOn Wi-Fi telemetry: Open dispenser wax motor or solenoid actuator coil (~1.5–3.0 kΩ), mechanical latch jam, or broken door wiring.

Remove inner door panel. Measure dispenser actuator coil resistance (~1.5–3.0 kΩ). Check spring-loaded flap latch for smooth movement. Press and hold Start/Reset for 5 seconds until the LED rapid flash ends, close door to initiate 60s drain cycle, then power off.

Diagnose
Ed
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Defrost heating circuit failure Ed; evaporator defrost heater fails to terminate cycle within programmed maximum runtime.

On Candy refrigeration units featuring Fresco Total No-Frost dual-circulation cooling, multi-sensor temperature regulation, and inverter compressor: Blown thermal cutoff fuse (72°C/77°C), burned calrod or glass defrost heating element, or stuck defrost relay.

Check defrost heating element resistance (typically 180-280 Ω). Verify continuity across thermal fuse (0 Ω; replace if open). Check 230V AC output from main PCB defrost relay. Reset: Press and hold Temp Set and Super Cool buttons together for 8 seconds until the display chime signals memory clear, then release.

Diagnose
EF
Dishwasher
Water Level Pressure Switch & Air Dome

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Flowmeter pulse overflow anomaly EF; impulse count exceeds maximum safety tank volume during filling phase.

On Candy dishwashers featuring Brava high-pressure wash hydraulics, Maxi Tub basket architecture, and Smart Touch / hOn Wi-Fi telemetry: Siphoning water leaking continuously out of drain hose during fill, or defective pressure switch failing to register water depth.

Check drain hose standpipe height (must be between 65 cm and 100 cm). Clear pressure switch dome in sump. Check pressure transducer contacts. Press and hold Start/Reset for 5 seconds until the LED rapid flash ends, close door to initiate 60s drain cycle, then power off.

Diagnose
EF
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Evaporator fan rotor stall / hardware trip EF; fan motor overcurrent detected by motor driver circuitry.

On Candy refrigeration units featuring Fresco Total No-Frost dual-circulation cooling, multi-sensor temperature regulation, and inverter compressor: Heavy Frost buildup surrounding fan blades, ice intrusion into motor hub, or shorted motor phase winding.

Perform complete 24h manual defrost to clear ice jacket. Verify fan spins freely by hand. Check winding resistance; replace fan if winding shorted. Reset: Press and hold Temp Set and Super Cool buttons together for 8 seconds until the display chime signals memory clear, then release.

Diagnose
Eh
Dishwasher
NTC Temperature Sensor & Thermistor

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Heating circuit safety thermal overheat Eh; water temperature sensor detects temperature exceeding 85°C.

On Candy dishwashers utilizing Brava high-pressure wash hydraulics, Maxi Tub basket architecture, and Smart Touch / hOn Wi-Fi telemetry: Welded heating relay contacts on main PCB keeping heater powered continually, or defective NTC sensor.

Disconnect mains immediately. Measure heater relay output voltage with machine in standby (must be 0V AC; if 230V AC present, relay is welded). Press and hold Start/Reset for 5 seconds until the LED rapid flash ends, close door to initiate 60s drain cycle, then power off.

Diagnose
EL
Dishwasher
Drainage System & Drain Pump

Candy Brava / RapidÓ / DiVino Smart Touch Dishwasher: Low incoming water pressure detected EL; flowmeter pulse cadence indicates line pressure under 0.5 bar.

On Candy dishwashers featuring Brava high-pressure wash hydraulics, Maxi Tub basket architecture, and Smart Touch / hOn Wi-Fi telemetry: Partially open supply stopcock, clogged sediment pre-filter in building plumbing, or shared simultaneous water usage.

Open inlet stopcock fully. Disconnect fill hose and run water into bucket to measure flow rate (minimum 8 liters per minute required). Press and hold Start/Reset for 5 seconds until the LED rapid flash ends, close door to initiate 60s drain cycle, then power off.

Diagnose
Er
Refrigerator / Freezer
Refrigeration Compressor, Defrost Heater & PTC Relay

Candy Fresco / Krio / City Combi Total No-Frost Refrigerator: Electronic controller EEPROM checksum error Er; microcontroller fails internal data validation checksum on power-up.

On Candy refrigeration units featuring Fresco Total No-Frost dual-circulation cooling, multi-sensor temperature regulation, and inverter compressor: Mains voltage surge or lightning strike spike, electrical storm noise, or degraded non-volatile memory cell.

Disconnect mains plug for 10 minutes to allow DC capacitors to discharge completely. If fault persists on reboot, replace programmed main board. Reset: Press and hold Temp Set and Super Cool buttons together for 8 seconds until the display chime signals memory clear, then release.

Diagnose
Er01
Oven / Microwave
NTC Temperature Sensor & Thermistor

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Cavity temperature sensor open circuit Er01; electronic controller reads infinite resistance from the PT500 / PT1000 oven probe.

On Candy ovens utilizing Timeless & Moderna precision convection thermal management, tangential cooling ventilation, and GIAS electronic programmer: Broken platinum resistor probe inside cavity, heat-damaged silicone wiring behind rear insulation, or loose PCB terminal.

Isolate power at breaker. Disconnect sensor plug at rear. Measure probe resistance (~538 Ω for PT500 or ~1078 Ω for PT1000 at 20°C). Replace if infinite. Turn programmer knob to Off, disconnect mains power at the isolation breaker for 60 seconds, restore power and set the electronic timer clock.

Diagnose
Er02
Oven / Microwave
NTC Temperature Sensor & Thermistor

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Cavity temperature sensor short circuit Er02; measured resistance across probe terminals drops below 100 Ω threshold.

On Candy ovens powered by Timeless & Moderna precision convection thermal management, tangential cooling ventilation, and GIAS electronic programmer: Pinching of probe lead wires by rear metal backplate screws, crushed fiberglass sleeving, or internal short in sensing bulb.

Inspect wiring harness from probe to PCB for pinched insulation. Verify probe resistance disconnected from PCB (nominal ~538 Ω / ~1078 Ω at 20°C). Turn programmer knob to Off, disconnect mains power at the isolation breaker for 60 seconds, restore power and set the electronic timer clock.

Diagnose
Er03
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Cavity overtemperature condition Er03; cavity temperature exceeds 320°C in standard baking or 520°C in pyrolytic clean mode.

On Candy ovens featuring Timeless & Moderna precision convection thermal management, tangential cooling ventilation, and GIAS electronic programmer: Welded heating element relay contacts on power board keeping elements energized continuously, or defective probe.

Disconnect power breaker immediately. Allow oven to cool down completely. Test heating element relay contacts on power PCB for short circuit. Turn programmer knob to Off, disconnect mains power at the isolation breaker for 60 seconds, restore power and set the electronic timer clock.

Diagnose
ER03
Hob / Cooktop
General System & Mechanical Integration

Candy Moderna / Idea / Smart Touch Induction Cooktop: Permanent touch key activation alarm ER03; liquid spill or cookware resting continuously on sensor controls.

On Candy cooktops utilizing Moderna & Idea high-frequency induction power generator, electromagnetic pan detection, and capacitive touch interface: Heavy liquid overflow across touch buttons, conductive sauce splatter, or pan overhang onto glass touch zone.

Remove all pots and utensils from glass. Sponge up all liquids and dry touch area thoroughly with a clean microfiber cloth. Wipe glass surface completely dry, power down circuit breaker for 60 seconds, restore supply and touch Key Lock for 5 seconds.

Diagnose
Er04
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Tangential cooling fan failure Er04; electronics cooling blower tachometer signal absent or speed falls below minimum RPM.

On Candy ovens utilizing Timeless & Moderna precision convection thermal management, tangential cooling ventilation, and GIAS electronic programmer: Jammed cross-flow fan impeller, open fan motor winding (~180–350 Ω), or defective Hall effect tachometer sensor.

Inspect tangential fan above cavity for free spin. Measure fan motor coil resistance (~180–350 Ω across terminals). Check Hall sensor 5V DC supply. Turn programmer knob to Off, disconnect mains power at the isolation breaker for 60 seconds, restore power and set the electronic timer clock.

Diagnose
Er05
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Pyrolysis door lock latch failure Er05; motorized latch mechanism fails to engage door interlock within 60 seconds of cycle start.

On Candy ovens powered by Timeless & Moderna precision convection thermal management, tangential cooling ventilation, and GIAS electronic programmer: Misaligned door catch hook, open synchronous latch motor coil (~2.0–4.5 kΩ), or defective lock microswitch.

Check door alignment and latch hook entry. Measure door lock synchronous motor resistance (~2.0–4.5 kΩ). Verify cam microswitch continuity when latched. Turn programmer knob to Off, disconnect mains power at the isolation breaker for 60 seconds, restore power and set the electronic timer clock.

Diagnose
Er06
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Pyrolysis door unlock timeout Er06; motorized latch mechanism fails to retract after cavity cools below safe temperature (~250°C).

On Candy ovens utilizing Timeless & Moderna precision convection thermal management, tangential cooling ventilation, and GIAS electronic programmer: Jammed mechanical cam linkage, defective unlock feedback switch, or power failure during unlock stroke.

Confirm cavity has fully cooled to room temperature. Manually actuate unlock cam mechanism from upper service access. Replace latch motor assembly. Turn programmer knob to Off, disconnect mains power at the isolation breaker for 60 seconds, restore power and set the electronic timer clock.

Diagnose
Er07
Oven / Microwave
General System & Mechanical Integration

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Food meat probe circuit fault Er07; internal core thermometer probe reads short-circuited or out-of-scale temperature.

On Candy ovens featuring Timeless & Moderna precision convection thermal management, tangential cooling ventilation, and GIAS electronic programmer: Liquid grease ingress inside meat probe jack socket on cavity wall, punctured probe silicone cord, or shorted connector.

Unplug meat probe from wall jack. Clean socket contact pins with isopropyl alcohol. Measure probe resistance with multimeter (~10 kΩ or ~1000 Ω depending on type). Turn programmer knob to Off, disconnect mains power at the isolation breaker for 60 seconds, restore power and set the electronic timer clock.

Diagnose
Er08
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Power relay board communication lost Er08; display interface loses serial handshake with heating element relay power module.

On Candy ovens utilizing Timeless & Moderna precision convection thermal management, tangential cooling ventilation, and GIAS electronic programmer: Disconnected or heat-damaged communication ribbon cable, power board transformer failure, or lost 12V DC rail.

Inspect multi-conductor cable connecting display to rear relay board. Reseat connectors and verify 12V DC and 5V DC power rails with voltmeter. Turn programmer knob to Off, disconnect mains power at the isolation breaker for 60 seconds, restore power and set the electronic timer clock.

Diagnose
Er09
Oven / Microwave
General System & Mechanical Integration

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Stuck touch control key error Er09; capacitive glass touch pad detects continuous activation for longer than 30 seconds.

On Candy ovens powered by Timeless & Moderna precision convection thermal management, tangential cooling ventilation, and GIAS electronic programmer: Grease film, liquid spillage, metal pot handle resting against touch glass, or damaged capacitive sensing spring.

Clean and dry the entire glass control fascia with microfiber cloth and glass cleaner. Ensure no objects touch glass. Power cycle breaker if persists. Turn programmer knob to Off, disconnect mains power at the isolation breaker for 60 seconds, restore power and set the electronic timer clock.

Diagnose
Er15
Oven / Microwave
NTC Temperature Sensor & Thermistor

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Electronics housing ambient overtemperature Er15; control board internal thermal sensor detects temperature exceeding 85°C.

On Candy ovens utilizing Timeless & Moderna precision convection thermal management, tangential cooling ventilation, and GIAS electronic programmer: Failed cooling fan motor, blocked cabinetry ventilation slots, or thermal insulation blanket compression.

Verify cooling fan operates during bake cycle. Ensure cabinet has minimum 50 mm rear air ventilation gap. Check board NTC sensor calibration. Turn programmer knob to Off, disconnect mains power at the isolation breaker for 60 seconds, restore power and set the electronic timer clock.

Diagnose
Er20
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Microcontroller flash memory checksum fault Er20; internal processor ROM memory block verification fails at boot.

On Candy ovens powered by Timeless & Moderna precision convection thermal management, tangential cooling ventilation, and GIAS electronic programmer: Mains power surge damage to microcontroller flash sector, electrical line noise, or incomplete firmware programming.

Power down at breaker for 15 minutes to clear RAM. If error reoccurs upon power restoration, main control module requires replacement. Turn programmer knob to Off, disconnect mains power at the isolation breaker for 60 seconds, restore power and set the electronic timer clock.

Diagnose
ER20
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Candy Moderna / Idea / Smart Touch Induction Cooktop: Microcontroller flash / EEPROM checksum error ER20; induction power board parameter registers corrupted.

On Candy cooktops featuring Moderna & Idea high-frequency induction power generator, electromagnetic pan detection, and capacitive touch interface: High-voltage inductive spike from cooking zone switching, mains supply transient, or memory cell fatigue.

Power off cooker circuit breaker for 10 minutes to reset microcomputer registers. If error persists on power up, replace induction power board. Wipe glass surface completely dry, power down circuit breaker for 60 seconds, restore supply and touch Key Lock for 5 seconds.

Diagnose
Er21
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Low-voltage DC power supply ripple fault Er21; 5V DC or 12V DC power bus voltage drops below operating threshold.

On Candy ovens utilizing Timeless & Moderna precision convection thermal management, tangential cooling ventilation, and GIAS electronic programmer: Dried electrolytic filter capacitors on switch-mode power supply, shorted optocoupler, or excessive relay coil current draw.

Measure DC voltages across power supply test points with multimeter (must read clean 5.0V DC and 12.0V DC without AC ripple). Replace power board if low. Turn programmer knob to Off, disconnect mains power at the isolation breaker for 60 seconds, restore power and set the electronic timer clock.

Diagnose
ER21
Hob / Cooktop
General System & Mechanical Integration

Candy Moderna / Idea / Smart Touch Induction Cooktop: Ambient electronics housing temperature exceeded ER21; internal temperature inside cooktop enclosure exceeds 85°C.

On Candy cooktops powered by Moderna & Idea high-frequency induction power generator, electromagnetic pan detection, and capacitive touch interface: Blocked cabinetry ventilation intake/exhaust, pyrolytic oven installed underneath running a self-clean cycle, or failed cooling fan.

Turn off all cooking zones and allow 20 minutes to cool. Verify cabinetry ventilation slots are unobstructed. Check cooling fan rotation. Wipe glass surface completely dry, power down circuit breaker for 60 seconds, restore supply and touch Key Lock for 5 seconds.

Diagnose
Er22
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Touch control panel matrix evaluation error Er22; touch controller detects invalid internal scanning line pattern.

On Candy ovens featuring Timeless & Moderna precision convection thermal management, tangential cooling ventilation, and GIAS electronic programmer: Moisture condensation between glass panel and touch PCB, mechanical displacement of touch springs, or controller IC defect.

Dismantle fascia panel and clean/dry glass inner surface. Ensure all conductive spring contacts sit centered on designated capacitive pad zones. Turn programmer knob to Off, disconnect mains power at the isolation breaker for 60 seconds, restore power and set the electronic timer clock.

Diagnose
ER22
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Candy Moderna / Idea / Smart Touch Induction Cooktop: Touch control evaluation hardware fault ER22; capacitive sensing integrated circuit detects an internal analog front-end failure.

On Candy cooktops utilizing Moderna & Idea high-frequency induction power generator, electromagnetic pan detection, and capacitive touch interface: Conductive liquid leakage inside the chassis onto touch sensor PCB, broken capacitive spring pin, or static discharge damage.

Open hob housing. Inspect touch sensor PCB for liquid stains or corrosion. Clean contacts with isopropyl alcohol. Replace touch PCB if hardware damaged. Wipe glass surface completely dry, power down circuit breaker for 60 seconds, restore supply and touch Key Lock for 5 seconds.

Diagnose
Er31
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

Candy Pop / Smart / Moderna / Timeless Pyrolytic Oven: Appliance variant model configuration error Er31; EEPROM parameters do not match installed hardware options (rotisserie, pyro, steam).

On Candy ovens utilizing Timeless & Moderna precision convection thermal management, tangential cooling ventilation, and GIAS electronic programmer: Unprogrammed replacement PCB installed, incorrect service code entered during board replacement, or memory corruption.

Enter factory diagnostic mode and input the 16-digit variant configuration code from the oven side rating label. Confirm and store settings. Turn programmer knob to Off, disconnect mains power at the isolation breaker for 60 seconds, restore power and set the electronic timer clock.

Diagnose
← Previous PagePage 4 of 6 (167 results)Next Page →

Candy — Complete Error Code Catalog

167 Verified Error Codes

Server-side index of all verified manufacturer error codes for technicians and automated crawlers.

Candy — Dishwasher30

AL03AL05E01E1E02E2E03E3E04E4E05E5E06E6E07E7E08E8E9E10E12E14E15E16E17E18EdEFEhEL

Candy — Washing Machine35

CLrE01E1E02E2E03E3E04E4E05E06E07E7E08E09E10E11E12E13E14E15E16E17E18E20E21E22F3F4F7FAFC0FC1FC2Unb

Candy — Tumble Dryer25

E01E02E03E04E05E06E07E08E09E10E11E12E13E14E15E16E17E18E21F1F2F3F4F5F6

Candy — Oven / Microwave29

Er01Er02Er03Er04Er05Er06Er07Er08Er09Er15Er20Er21Er22Er31Er36Er47Er56F0F1F2F3F4F5F7F8F9LocSabbSTOP

Candy — Hob / Cooktop25

E0E1E2E3E4E5E6E7E8E9ER03ER20ER21ER22ER31ER36ER47F0F1F2F7F8F9LU

Candy — Refrigerator / Freezer23

AL01AL02E0E1E2E3E4E5E6E7E8E9EAEdEFErF0F1F2F3F4F5F6

Need Help? Call a Certified Technician

Our official certified partners service Candy appliances in your area.

Electroassistance (Switzerland)Appliance Care UK (United Kingdom)
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy