Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
Ignis • Central Diagnostic Dictionary
138 Verified Codes in Database

Ignis Error Codes & Diagnostics

Access our premium database of error codes, common faults, and professional repair solutions for Ignis appliances.

Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum

Ignis — Known Error Codes

CodeAppliancesFault / DiagnosticsRepair InstructionsAction
F12
Tumble Dryer
Heating Element, Thermostat & Safety Fuse

Ignis IGT AirVented & Condenser Tumble Dryer: Moisture sensor electrode open circuit F12; conductivity sensing bars read permanent infinite resistance during wet cycle.

On Ignis tumble dryers: Disconnected slip ring wiper contact on front drum baffle, broken sensor lead, or heavy calcium coating on sensing bars.

Clean sensor bars with fine sandpaper and vinegar. Inspect carbon brush slip contact riding on drum shell. Verify wiring continuity to electronic board. Press and hold Start key for 4 seconds, clear lint trap and reset high-limit safety thermostat.

Diagnose
F12
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Ignis Platino Induction & Ceramic Cooktop: Induction power relay drive line failure F12; high-current relay fails to energize coil zone when power booster is commanded.

On Ignis cooktops: Open transistor switch on 12V relay bus, open circuit in relay coil, or broken PCB trace following inductive transient spike.

Measure continuity of power relay coils (350–450 Ω). Check transistor collector voltage during booster actuation (drops to ~0.7V DC). Replace relay or PCB. Power down at breaker switch for 60 seconds, wipe surface dry with microfiber cloth, then restart.

Diagnose
F12
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

Ignis TuttoinUno Built-in Convection Oven: Rotary function encoder or mode selector potentiometer defective F12; control PCB reads invalid selection matrix signals.

On Ignis ovens: Oxidation on rotary selector switch wiper tracks, cracked solder pins on encoder PCB, or spilled cleaning fluid inside bezel.

Disassemble front console. Clean rotary encoder contacts with isopropyl alcohol and dry thoroughly. Resolder cracked pins or replace selector switch. Switch selector to Off, isolate power at circuit breaker for 60 seconds, then re-energize.

Diagnose
F12
Washing Machine
Electronic Control Board (PCB) & Bus Communications

Ignis LTE Top-Loader & TuttoinUno Front-Loader Washing Machine: UI to main control PCB communication loss F12; display board fails to exchange handshake packets with base power module.

On Ignis washing appliances: Corroded data bus ribbon cable between console and lower chassis, cold solder joints, or 5V DC standby power supply ripple.

Check ribbon cable connectors between display and power PCB. Verify stable 5V DC and 12V DC on power board test points. Reseat connectors or replace faulty PCB. Hold Start/Cancel button for 5 seconds until indicator light turns solid, switch off, and turn knob to 0.

Diagnose
F13
Dishwasher
Drainage System & Drain Pump

Ignis ADL & TuttoinUno Platinum Compact Dishwasher: Detergent dispenser actuator triac fault F13; combination dispenser solenoid fails to energize or draw holding current.

On Ignis dishwashers: Burnt wax motor or open solenoid coil in inner door dispenser assembly, or failed switching triac on power board.

Disconnect inner door panel. Measure dispenser actuator solenoid resistance (nominal 1.2–2.5 kΩ, or 800–1600 Ω wax motor). Replace dispenser unit if coil open. Press and hold Start button for 5 seconds to force drain cycle, wait 60s, then switch off power switch.

Diagnose
F13
Tumble Dryer
NTC Temperature Sensor & Thermistor

Ignis IGT AirVented & Condenser Tumble Dryer: Condenser heat exchanger NTC thermistor fault F13; evaporator temperature sensor value out of calibration range.

On Ignis heat pump dryers: Wet lint clogged around heat pump evaporator fins, dislodged NTC clip on copper pipe, or sensor thermistor failure.

Clean heat exchanger fins with soft fin comb. Ensure NTC probe is firmly clipped to refrigerant tube. Measure resistance: nominal ~10 kΩ at 25°C. Press and hold Start key for 4 seconds, clear lint trap and reset high-limit safety thermostat.

Diagnose
F13
Oven / Microwave
General System & Mechanical Integration

Ignis TuttoinUno Built-in Convection Oven: Food meat probe socket short circuit to chassis earth F13; controller detects abnormal low impedance on meat probe input jack.

On Ignis ovens: Grease and moisture condensation inside side-wall probe jack receptacle, pinched probe harness against metal side panel, or damaged jack housing.

Clean interior of probe jack with cotton swab and degreaser. Check jack terminal insulation to oven chassis (> 10 MΩ). Replace jack assembly if shorted. Switch selector to Off, isolate power at circuit breaker for 60 seconds, then re-energize.

Diagnose
F13
Washing Machine
NTC Temperature Sensor & Thermistor

Ignis LTE Top-Loader & TuttoinUno Front-Loader Washing Machine: Dispenser diverter actuator or drying NTC sensor fault F13; detergent compartment motor out of sync or drying thermistor open.

On Ignis washing appliances: Stripped diverter gear cog in water dispenser top, seized micro-gearbox, or open circuit on washer-dryer drying duct NTC.

Inspect dispenser water nozzle gearing for mechanical binding. Measure diverter motor resistance (~4.5–6.0 kΩ). On washer-dryers, test drying NTC (~20 kΩ at 25°C). Hold Start/Cancel button for 5 seconds until indicator light turns solid, switch off, and turn knob to 0.

Diagnose
F14
Dishwasher
Water Level Pressure Switch & Air Dome

Ignis ADL & TuttoinUno Platinum Compact Dishwasher: Virtual water level sensor calculation discrepancy F14; algorithm detects mismatch between circulation pump torque and water presence.

On Ignis dishwashers: Foaming detergent cavitating circulation pump, clogged fine filter starving water intake, or low line voltage altering motor power factor.

Clean sump stainless steel fine filter. Check for soap foam in tub (add 1 tbsp cooking oil to collapse bubbles). Verify stable 230V mains voltage. Press and hold Start button for 5 seconds to force drain cycle, wait 60s, then switch off power switch.

Diagnose
F14
Tumble Dryer
Heating Element, Thermostat & Safety Fuse

Ignis IGT AirVented & Condenser Tumble Dryer: Heat pump inverter compressor IPM overcurrent protection F14; drive module detects compressor phase over-amperage or lockup.

On Ignis heat pump tumble dryers: Refrigerant circuit pressure unbalance, shorted BLDC compressor stator winding, or failed inverter power module.

Allow 20 minutes for refrigerant pressure equalization. Measure compressor terminal resistances across all 3 phases (symmetrical ~8–14 Ω). Replace inverter or compressor. Press and hold Start key for 4 seconds, clear lint trap and reset high-limit safety thermostat.

Diagnose
F14
Oven / Microwave
NTC Temperature Sensor & Thermistor

Ignis TuttoinUno Built-in Convection Oven: Meat probe reading exceeds maximum allowable temperature limit F14; probe input registers temperature exceeding 110°C.

On Ignis ovens: Meat probe inserted incorrectly or left exposed directly to radiant grill heat, internal thermistor breakdown, or probe handle contact with flame.

Unplug meat probe from cavity wall. Allow to cool. Test probe resistance at ambient 20°C: nominal ~1000 Ω (PT1000) or ~47 kΩ (NTC). Insert fully into center of roast. Switch selector to Off, isolate power at circuit breaker for 60 seconds, then re-energize.

Diagnose
F14
Washing Machine
Electronic Control Board (PCB) & Bus Communications

Ignis LTE Top-Loader & TuttoinUno Front-Loader Washing Machine: Main PCB microcontroller EEPROM memory checksum error F14; corrupt firmware settings block program execution.

On Ignis washing appliances: Voltage brownout during non-volatile memory write cycle, electrical grid noise, or damaged EEPROM chip on Arcadia / WAVE board.

Perform complete electrical power discharge (unplug for 10 minutes). If fault recurs, reflash EEPROM firmware using factory service interface or replace main PCB. Hold Start/Cancel button for 5 seconds until indicator light turns solid, switch off, and turn knob to 0.

Diagnose
F15
Dishwasher
Drainage System & Drain Pump

Ignis ADL & TuttoinUno Platinum Compact Dishwasher: Circulation pump motor Hall sensor disconnect F15; inverter control board loses position pulse feedback from BLDC stator.

On Ignis dishwashers: Defective Hall IC on pump rear circuit, loose 3-wire signal plug on DEA700 power module, or moisture ingress into sensor cavity.

Inspect 3-wire Hall sensor connector on circulation pump and main PCB. Check 5V DC supply to sensor. If wiring intact and error persists, replace circulation pump. Press and hold Start button for 5 seconds to force drain cycle, wait 60s, then switch off power switch.

Diagnose
F15
Tumble Dryer
Heating Element, Thermostat & Safety Fuse

Ignis IGT AirVented & Condenser Tumble Dryer: Drum belt tensioner safety switch open F15; microswitch on motor jockey arm trips due to loose or broken drive belt.

On Ignis tumble dryers: Snapped drive belt, dislocated belt tensioner jockey wheel, or defective safety cutoff switch on motor cradle.

Remove side panel and inspect belt path. Mount new elastic poly-V belt around motor pulley and drum. Test tensioner switch continuity (< 1 Ω closed). Press and hold Start key for 4 seconds, clear lint trap and reset high-limit safety thermostat.

Diagnose
F15
Washing Machine
Heating Element, Thermostat & Safety Fuse

Ignis LTE Top-Loader & TuttoinUno Front-Loader Washing Machine: Drum position sensor (DSP) or dryer heating relay fault F15; drum flap alignment sensor missing or washer-dryer relay stuck.

On Ignis top-loaders and washer-dryers: Pulley magnet detached, reed sensor displaced on tub exterior, or welded contacts on drying heater relay.

Inspect drum pulley magnet and verify reed switch closure with handheld magnet. On washer-dryers, test drying relay coils (12V DC) and continuity. Hold Start/Cancel button for 5 seconds until indicator light turns solid, switch off, and turn knob to 0.

Diagnose
F16
Washing Machine
Door Lock Mechanism & Safety Interlock

Ignis LTE Top-Loader & TuttoinUno Front-Loader Washing Machine: Drum lock top-loader safety interlock fault F16; microswitch indicates drum gate not secured at spin cycle initiation.

On Ignis top-loading washers: Drum access flap latch not fully clicked into keeper, broken mechanical gate catch, or failed optical sensor beam.

Open top lid and manually confirm positive click-lock of both drum flap latches. Inspect gate spring hinges. Measure gate switch continuity (< 1 Ω closed). Hold Start/Cancel button for 5 seconds until indicator light turns solid, switch off, and turn knob to 0.

Diagnose
F18
Washing Machine
Drainage System & Drain Pump

Ignis LTE Top-Loader & TuttoinUno Front-Loader Washing Machine: Excessive foam overdosing warning F18; pressure transducer senses suds accumulation preventing drain pump priming.

On Ignis washing machines: High-foaming non-HE detergent used, massive overdose of liquid soap, or partially restricted drain hose trap.

Allow suds to settle naturally for 30 minutes. Run cold rinse cycle without detergent. Clean drain filter and adjust future detergent dosing. Hold Start/Cancel button for 5 seconds until indicator light turns solid, switch off, and turn knob to 0.

Diagnose
F20
Tumble Dryer
NTC Temperature Sensor & Thermistor

Ignis IGT AirVented & Condenser Tumble Dryer: Upper lint filter air flow restriction F20; airflow thermistor senses thermal rise due to clogged door lint screen.

On Ignis tumble dryers: Thick lint mat over fine mesh door screen, fabric softener film blocking air pores, or obstructed front duct throat.

Wash door lint filter under hot running water with mild dish soap to clear invisible films. Vacuum out the lower filter chute before resuming cycle. Press and hold Start key for 4 seconds, clear lint trap and reset high-limit safety thermostat.

Diagnose
F20
Washing Machine
Drainage System & Drain Pump

Ignis LTE Top-Loader & TuttoinUno Front-Loader Washing Machine: Water inlet and heater temperature discrepancy F20; wash water fails to heat while continuous cold water entry is detected.

On Ignis washers: Siphoning effect through low standpipe (< 65 cm), leaking inlet valve triac, or simultaneous drain and fill conditions.

Raise drain hose apex between 65 cm and 100 cm height. Check for siphon seal. Inspect inlet valve for electrical or mechanical leakage. Hold Start/Cancel button for 5 seconds until indicator light turns solid, switch off, and turn knob to 0.

Diagnose
F21
Tumble Dryer
Heating Element, Thermostat & Safety Fuse

Ignis IGT AirVented & Condenser Tumble Dryer: Display to power module serial handshake loss F21; communication line fails periodic liveness heartbeat check.

On Ignis tumble dryers: Vibration-induced fretting corrosion on console plug terminals, damaged data wire, or electromagnetic interference from motor.

Disconnect and reseat data ribbon cable. Apply electronic contact lubricant to connector pins. Verify grounding strap between motor and chassis. Press and hold Start key for 4 seconds, clear lint trap and reset high-limit safety thermostat.

Diagnose
F21
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Ignis Platino Induction & Ceramic Cooktop: Serial communication bus timeout between power and UI modules F21; continuous framing errors disrupt induction coil firing.

On Ignis cooktops: Electrical noise coupling into data ribbon cable from high-frequency induction coils, loose connector latch, or faulty transceiver IC.

Reroute data ribbon cable away from high-voltage induction coil leads. Ensure ferrite clamp is installed around cable. Test 5V DC transceiver supply. Power down at breaker switch for 60 seconds, wipe surface dry with microfiber cloth, then restart.

Diagnose
F21
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

Ignis LTE Top-Loader & TuttoinUno Front-Loader Washing Machine: User interface serial communication line error F21; console board loses synchronous data stream with core motor controller.

On Ignis washing appliances: Damaged serial communication line harness, loose pin crimp, moisture on UI circuit board, or electrical inverter surge.

Inspect wiring harness continuity between console board and motor controller. Clean edge connectors with contact cleaner. Verify 5V DC supply rail. Hold Start/Cancel button for 5 seconds until indicator light turns solid, switch off, and turn knob to 0.

Diagnose
F22
Tumble Dryer
Refrigeration Compressor, Defrost Heater & PTC Relay

Ignis IGT AirVented & Condenser Tumble Dryer: Heat pump compressor discharge overtemperature warning F22; high-pressure line thermistor exceeds 115°C safety ceiling.

On Ignis heat pump dryers: Severely blocked bottom condenser filter choking airflow, slow evaporator blower fan, or micro-leak in R134a/R290 gas circuit.

Clean or replace lower foam condenser filter block. Vacuum aluminum heat exchanger fins. Verify secondary cooling fan operates freely during drying. Press and hold Start key for 4 seconds, clear lint trap and reset high-limit safety thermostat.

Diagnose
F22
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

Ignis LTE Top-Loader & TuttoinUno Front-Loader Washing Machine: Motor drive inverter module overcurrent fault F22; IPM power silicon senses short circuit or excessive motor stator phase current.

On Ignis washing appliances: Shorted winding in 3-phase BLDC motor stator, locked drum mechanical assembly, or punctured IGBT bridge on power board.

Measure resistance between motor phase pins U-V, V-W, U-W (must be symmetrical, 6.5–8.5 Ω per phase). Test for zero resistance across IGBT output terminals. Hold Start/Cancel button for 5 seconds until indicator light turns solid, switch off, and turn knob to 0.

Diagnose
F23
Tumble Dryer
Water Level Pressure Switch & Air Dome

Ignis IGT AirVented & Condenser Tumble Dryer: Lower condenser filter blockage warning F23; differential pressure switch or temperature delta detects restricted air path.

On Ignis tumble dryers: Compressed sponge filter saturated with damp lint in bottom plinth compartment, or warped filter frame allowing air bypass.

Open plinth door, pull out foam filter element, wash thoroughly under running water, squeeze dry with towel, and reinstall firmly into cassette housing. Press and hold Start key for 4 seconds, clear lint trap and reset high-limit safety thermostat.

Diagnose
F23
Washing Machine
Water Level Pressure Switch & Air Dome

Ignis LTE Top-Loader & TuttoinUno Front-Loader Washing Machine: Simultaneous empty and full pressure switch signals F23; logic inconsistency detected between dual pressure contacts.

On Ignis washers: Moisture inside mechanical pressure switch capsule, oxidation on pressure contacts, or soap scum blocking pressure tube orifice.

Inspect and clear pressure switch nipple and chamber. Check continuity across contact pins 11-12 (empty, 0 Ω) and 11-14 (full, open when tub is drained). Hold Start/Cancel button for 5 seconds until indicator light turns solid, switch off, and turn knob to 0.

Diagnose
F24
Tumble Dryer
Heating Element, Thermostat & Safety Fuse

Ignis IGT AirVented & Condenser Tumble Dryer: Electronic humidity sensing amplifier calibration drift F24; analog-to-digital converter reports uncalibrated reference voltage.

On Ignis tumble dryers: High ambient humidity during calibration check, dried-out electrolytic filtering capacitor on PCB, or defective operational amplifier IC.

Ventilate laundry room to lower ambient humidity below 70%. Ensure drum is completely empty and dry. Execute factory diagnostic self-calibration routine. Press and hold Start key for 4 seconds, clear lint trap and reset high-limit safety thermostat.

Diagnose
F24
Washing Machine
Water Level Pressure Switch & Air Dome

Ignis LTE Top-Loader & TuttoinUno Front-Loader Washing Machine: Overflow water level threshold tripped F24; critical safety level exceeded, engaging emergency drain routine.

On Ignis washers: Mechanically jammed inlet water valve allowing unmetered filling, or defective triac supplying continuous 230V to inlet solenoid.

Shut off water isolation valve. Check if water continues flowing with mains unplugged (valve jammed open). If stops, test triac output on main board. Hold Start/Cancel button for 5 seconds until indicator light turns solid, switch off, and turn knob to 0.

Diagnose
F25
Hob / Cooktop
NTC Temperature Sensor & Thermistor

Ignis Platino Induction & Ceramic Cooktop: Rear induction zone center temperature sensor disconnect F25; glass ceramic sensor spring probe circuit open.

On Ignis cooktops: Broken copper wire at coil center spring eyelet, oxidized plug on generator board, or cracked ceramic thermistor chip.

Unclip glass top and access rear induction coil. Measure center spring NTC probe resistance (nominal ~100 kΩ at 25°C). Replace central coil sensor. Power down at breaker switch for 60 seconds, wipe surface dry with microfiber cloth, then restart.

Diagnose
F26
Washing Machine
Drainage System & Drain Pump

Ignis LTE Top-Loader & TuttoinUno Front-Loader Washing Machine: Main drain pump triac driver fault F26; power board detects shorted or open triac output stage to pump motor.

On Ignis washing machines: Water ingress into drain pump motor body causing winding short circuit that punctures the board triac driver.

Inspect drain pump for signs of water leaking down shaft into coil. Measure pump resistance (160–185 Ω). Replace pump and repair or replace power module. Hold Start/Cancel button for 5 seconds until indicator light turns solid, switch off, and turn knob to 0.

Diagnose
← Previous PagePage 4 of 5 (138 results)Next Page →

Ignis — Complete Error Code Catalog

78 Verified Error Codes

Server-side index of all verified manufacturer error codes for technicians and automated crawlers.

Dishwasher28

E1E2E3E4E5E6E7E8E9F1F2F3F4F5F6F7F8F9F10F11F12F13F14F15FAFBFCFE

Washing Machine12

BDDF16F18F26F27F28F29FDLFDUFHFODSUD

Tumble Dryer14

F01F02F03F04F05F06F07F08F09F20F21F22F23F24

Oven / Microwave4

F1EF2EF3EF6E

Hob / Cooktop11

C81C82C83C84C85F25F36F37F40F42F47

Refrigerator / Freezer9

A1A2AL01AL02AL03CECFdEPO

Need Help? Call a Certified Technician

Our official certified partners service Ignis appliances in your area.

Electroassistance (Switzerland)Appliance Care UK (United Kingdom)
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy