Ignis LTE Top-Loader & TuttoinUno Front-Loader Washing Machine: Drum reversing motor relay contact stuck F27; motor can rotate in only one direction due to welded relay contacts.
On Ignis washing appliances: High inductive arc discharge during drum reversal under heavy laundry load welding reversing relay contacts on PCB.
De-energize machine. Tap relay casing lightly or measure contact continuity with power off (normally open contacts must read infinite ohms). Replace PCB relay. Hold Start/Cancel button for 5 seconds until indicator light turns solid, switch off, and turn knob to 0.