Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
ENFRDEITESPT
ENEnglishFRFrançaisDEDeutschITItalianoESEspañolPTPortuguês
Account & Access
Upgrade PRO
Back to Search
Siemens • Central Diagnostic Dictionary
202 Verified Codes in Database

Siemens Error Codes & Diagnostics

Access our premium database of error codes, common faults, and professional repair solutions for Siemens appliances.

Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum

Siemens — Complete OEM Fault Code Matrix & Reference Table

Official diagnostic reference matrix of Siemens error codes, symptom descriptions, and verified technical inspection points.

202 / 202 results
Official diagnostic reference matrix of Siemens error codes, symptom descriptions, and verified technical inspection points.
CodeAppliancesSymptom / Fault DescriptionPrimary Component / Test PointAction
ALRefrigerator

Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: High temperature cavity alarm AL; freezer temperature has risen above critical threshold of -9°C for over 60 minutes.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
d0Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Showroom demo mode active d0; displays and touch sliders illuminate and respond but power elements do not heat.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
d1Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Front left cooking zone demo test locked d1; front left inverter locked in display simulation loop.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
d2Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Rear left cooking zone demo test locked d2; rear left induction channel disabled in demo simulation mode.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
d3Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Center / rear right cooking zone demo test locked d3; zone controller in exhibition simulation state.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
d4Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Front right cooking zone demo test locked d4; front right power stage disabled in store demonstration mode.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
d5Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: FlexInduction bridging relay check state d5; induction coil coupling relays engaged in diagnostic cycle.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
d6Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Forced high-speed cooling fan test mode active d6; fan runs continuously at maximum RPM for thermal evaluation.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
d7Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Mains voltage telemetry feedback display d7; digital voltmeter diagnostic screen showing live input AC voltage.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
d8Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Touch slider sensitivity calibration mode d8; user interface enters capacitive touch gain tuning display.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
d9Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Factory end-of-line (EOL) test loop active d9; automated manufacturing test routine repeating test steps.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
dEHob

Hob is in demonstration mode

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
Demo ModeRefrigerator

Lights and display work but appliance does not cool

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E0Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Control unit configuration error E0; touch module EEPROM parameter mismatch prevents zone activation.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E01Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Critical power module failure E01; heating circuit relay contacts open or welded on the main control board.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E01Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Process air circulation blockage E01; lint filter or air channel clogged, stopping drying cycle.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E01Refrigerator

Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: Fridge compartment temperature sensor failure E01; fresh food zone NTC sensor circuit open or shorted.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E1Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Internal bus communication failure E1; user interface loses serial data link with induction power generator.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E02Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Auxiliary heating relay malfunction E02; secondary safety relay on power PCB fails to close during water heating phase.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E02Refrigerator

Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: Evaporator defrost temperature sensor fault E02; defrost termination NTC sensor out of range or open circuit.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
E2Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Induction coil temperature sensor over-temperature E2; coil NTC thermistor registers > 240°C or short circuit.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E03Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Auxiliary heating relay circuit discrepancy E03; microprocessor detects inconsistent contact state across heating relays.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E03Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Maximum drying cycle time limit exceeded E03; laundry remains damp after programmed 4-hour cycle timeout.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E03Refrigerator

Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: Chiller / VitaFresh compartment sensor fault E03; meat/fish preservation drawer NTC registers invalid readings.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E3Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Mains over-voltage detected E3; supply voltage on phase L1/L2 exceeds safe threshold of 275V AC.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E04Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Water switch diverter position feedback failure E04; upper/lower spray arm alternator disc position unknown.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E04Refrigerator

Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: Ambient room temperature sensor fault E04; external temperature NTC located at top hinge cover disconnected or open.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E4Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Mains under-voltage detected E4; AC line voltage drops below 185V AC under load during active heating.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E005Oven

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Power interlock safety relay failure E005; safety relay on power PCB fails to close power circuit to heating elements.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E05Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Water switch motor triac short-circuit E05; electronic controller cannot regulate water diverter valve motor.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E05Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Condensate drain pump triac / circuit failure E05; water accumulated during drying cannot be pumped into collection tank.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E05Refrigerator

Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: Freezer compartment air temperature sensor fault E05; freezer interior cavity NTC sensor circuit open or shorted.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
E5Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Left induction generator module fault E5; power board phase L1 fails internal self-test or IGBT gate driver trip.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E06Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Door Hall sensor latch anomaly E06; control unit detects open door signal or invalid magnetic reed feedback during cycle.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E06Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Heating element power relay fault E06; control module relay contacts fail to switch power to heater assembly.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E6Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Right induction generator module fault E6; power board phase L2 fails internal diagnostic cycle.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E07Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Zeolith drying fan / airflow restriction E07; zeolite air circulation blower motor blocked or thermistor out of spec.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E7Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Cooling fan malfunction E7; tachometer feedback signal missing or fan motor speed falls below 500 RPM.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E08Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Low water level in sump during heating E08; heat pump detects insufficient water coverage over heating ring.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
E08Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Heat pump auxiliary relay / defrost fault E08; heat pump evaporator icing up or defrost cycle fails to initiate.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E8Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Cookware detection fault E8; resonant circuit fails to establish stable magnetic coupling with pan bottom.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E09Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Heating circuit open failure E09; heat pump heating element open circuit, water remains cold throughout cycle.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E09Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Heating circuit open circuit error E09; heating element coil open or thermal fuse blown, drum blows cold air.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E9Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Touch panel capacitive calibration failure E9; touch sensor controller detects finger contact during system boot sequence.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E10Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Scale build-up on heating element E10; reduced heat transfer efficiency and slow water temperature rise.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E10Refrigerator

Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: Compressor inverter communication failure E10; master control board loses serial telemetry link with inverter PCB.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
E011Oven

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Stuck capacitive touch key sensor E011; touch control surface senses permanent touch activation for > 10 seconds.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E11Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: NTC temperature sensor fault E11; thermistor resistance signal open, shorted, or outside calibration limits.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E11Refrigerator

Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: Display user interface communication error E11; door display panel fails serial handshake with power electronics.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E12Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Severe lime scale build-up warning E12; thermal sensors detect heat retention on heating ring during drain.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E13Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: High water inlet temperature E13; intake water exceeds maximum design temperature limit (> 75°C).

Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose
E14Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Flowmeter turbine impulse signal missing E14; water fills but reed switch sensor fails to count pulses.

Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose
E15Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: AquaStop safety flood protection triggered E15; polystyrene float switch in base tray activated, drain pump runs continuously.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E15Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Safety high-limit thermostat tripped E15; heater housing overtemperature switch opened, shutting off heating coils.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E15Refrigerator

Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: Defrost heater system malfunction E15; evaporator heating element fails to melt frost within maximum defrost duration.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
E16Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Uncontrolled water inflow / solenoid valve leak E16; water continually enters tub even when inlet valve is de-energized.

Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose
E16Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Exhaust air temperature safety cutout E16; exhaust duct sensor exceeds safety temperature limit (> 95°C).

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E16Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Door interlock open fault E16; appliance cannot start wash program because door latch contacts remain unmade.

PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose
E17Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: High water inlet pressure / overflow risk E17; flow rate into heat exchanger exceeds maximum allowable speed.

Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose
E17Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Water inlet timeout alarm E17; appliance fails to reach required wash level within 5 minutes of filling.

Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose
E18Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Low water flow inlet timeout E18; minimum water volume not achieved within programmed filling time window.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E18Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Draining timeout failure E18; washer fails to evacuate tub wastewater within programmed 6-minute window.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E19Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Dispenser actuator / heat exchanger drainage valve coil failure E19; solenoid coil open circuit or triac blown.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E19Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Heating timeout error E19; wash water temperature fails to increase by at least 4°C within 15 minutes of heating.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E20Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Circulation pump BLDC winding resistance fault E20; phase impedance imbalance or open coil detected by inverter.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E20Refrigerator

Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: Inverter compressor drive failure E20; compressor fails to start, stalls under differential pressure, or draws excessive current.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
E20Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Unexpected heating fault E20; heater energized during cold rinse or water heats up without active command.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E21Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Circulation pump motor jammed / blocked impeller E21; motor fails to start, excessive current draw shuts down inverter.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E21Refrigerator

Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: Evaporator circulation fan motor failure E21; no-frost cold air circulation blower stopped or tachometer feedback missing.

Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose
E21Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Motor drive / rotation failure E21; drum does not rotate, drive motor fails to turn or accelerate into spin.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E22Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Sump filter blocked / residual water accumulation E22; fine mesh screen clogged by grease and food residues.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E22Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Wash tub NTC temperature sensor fault E22; thermistor signal open circuit or shorted to ground, cycle runs cold.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E23Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Drain pump winding resistance error E23; inverter reports open circuit, phase short, or coil defect in drain motor.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E23Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Condensate container overflow / float switch active E23; sump reservoir full, cycle pauses with water tank warning.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E23Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: AquaStop base float switch activated E23; water leak detected in bottom pan, safety drain pump runs continuously.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E24Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Drain hose obstruction / siphon block E24; appliance fails to expel waste water, pump stops after initial 1-minute test.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E25Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Drain pump impeller locked / pump cover missing E25; wastewater cannot be pumped out, standing water in tub bottom.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E25Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Turbidity AquaSensor optical fault E25; infrared sensor cannot evaluate rinse water cloudiness or clarity.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E26Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Water switch diverter valve mechanical jam E26; rotary distributor disc cannot complete rotation between spray arms.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E26Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Analog pressure sensor voltage out of range E26; sensor output signal voltage drops below 0.5V DC or exceeds 3.5V DC.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
E27Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Mains undervoltage detected E27; AC supply voltage drops below minimum operating threshold (< 190V AC).

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E27Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Pressure sensor zero-point calibration drift E27; sensor reports residual water pressure with completely empty tub.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E28Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Turbidity AquaSensor optical calibration fault E28; phototransistor cannot calibrate wash water clarity.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E28Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Flow sensor impulse signal missing E28; water enters soap dispenser but reed switch flowmeter counts 0 pulses.

Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose
E29Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Mains supply frequency out of tolerance E29; AC grid frequency deviates beyond acceptable 50 Hz / 60 Hz window.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E29Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Condensate drain siphon / line clogged E29; self-cleaning condenser flush line or external drain hose obstructed.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E29Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: No water inflow detected E29; inlet valves energized but pressure sensor detects zero water accumulation.

Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose
E30Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Mains overvoltage detected E30; supply line voltage exceeds upper operating safety limit (> 265V AC).

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E31Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Zeolith heat pump overheating safety trip E31; thermal cutout on drying container activated.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E31Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Maximum safety water level exceeded E31; overflow protection trips, inlet valves closed and drain pump energized.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
E32Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Moisture sensor conductivity circuit anomaly E32; sensor electrode strips report open circuit or permanent wet state.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E32Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Drum unbalanced load distribution warning E32; appliance aborts final spin or reduces speed to prevent vibration damage.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E34Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Door interlock failed to lock E34; solenoid pulse sent but lock mechanism fails to engage or confirm locked contact.

PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose
E35Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Door interlock failed to unlock E35; door remains locked at cycle end, unlock pulse fails to release mechanism.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
E36Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Door interlock switch open during program E36; door catch pops open or microswitch contacts bounce during rotation.

PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose
E36Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Door interlock sensing circuit fault E36; feedback line to microcontroller remains inconsistent with lock driver state.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E37Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: NTC sensor resistance open or high deviation E37; temperature value reads unrealistic cold (<-10°C) during wash.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E38Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: NTC temperature sensor short-circuit fault E38; sensor lines shorted together or to ground, reading > 120°C.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E42Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Uncontrolled motor runaway speed error E42; drive motor revs instantly to maximum RPM without speed ramping control.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E43Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Motor stalled / drum rotation mechanically locked E43; drive motor energized but drum cannot rotate.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E44Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: No bidirectional motor rotation E44; drum only turns in one direction during wash tumble, reversing relay stuck.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E47Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Motor inverter power module (IPM) overtemperature E47; thermal sensor on aluminum heatsink trips thermal shutdown.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E48Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Inverter DC bus undervoltage detected E48; rectified high-voltage DC rail drops below minimum threshold (< 200V DC).

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E49Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Inverter DC bus overvoltage detected E49; regenerated motor braking energy or AC mains surge exceeds safety limit (> 400V DC).

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E50Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: 3-phase BLDC motor drive hardware fault E50; inverter bridge reports phase current imbalance or shorted IGBT.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E51Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Motor inverter IPM short circuit E51; drive motor / compressor inverter trips instantly on overcurrent.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E52Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Drum drive motor inverter undervoltage E52; DC bus supply voltage drops below minimum operating threshold (< 200V DC).

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E53Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Drum drive motor inverter overvoltage E53; DC bus voltage exceeds upper safety limit (> 400V DC).

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E54Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Heat pump compressor inverter phase imbalance E54; current asymmetry detected across compressor 3-phase motor.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E55Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Compressor rotor locked / stalled E55; heat pump compressor fails to turn over, inverter trips on locked-rotor current.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E56Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Inverter heatsink thermal sensor overtemperature E56; power board temperature exceeds safe operating threshold (> 85°C).

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E57Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Inverter serial D-Bus communication lost E57; main control module loses serial data link to motor inverter module.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E59Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: 3D Hall acceleration sensor signal missing E59; tub motion sensor fails to report 3-axis vibration data during spin.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E60Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Flow sensor flow rate out of calibrated bounds E60; discrepancy between flowmeter pulse frequency and pressure rise.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
E61Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Abnormal door lock feedback signal E61; door interlock reports unexpected state changes during high-speed rotation.

PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose
E63Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Microcontroller safety watchdog fault E63; internal microprocessor registers report execution error, halting cycle.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E63Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Functional safety processor watchdog trip E63; internal CPU self-test parity or RAM execution error detected on main PCB.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E67Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Configuration variant coding error E67; EEPROM variant data mismatch between user interface and power module.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E71Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Compressor discharge temperature NTC sensor error E71; sensor resistance open, shorted, or out of calibration range.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E72Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Evaporator NTC defrost sensor failure E72; temperature sensor on heat pump evaporator coil open or shorted.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E73Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Condenser NTC sensor fault E73; temperature sensor on refrigerant condenser coil signal open or short-circuit.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E74Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Process air duct NTC sensor error E74; temperature thermistor in front air duct open or shorted.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E75Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Ambient temperature thermistor out of range E75; room temperature sensor reads outside safe operating envelope (< 5°C or > 40°C).

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E89Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Display UI to power module communication error E89; console display lost serial communication link with base power board.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E90Tumble Dryer

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Variant coding / configuration error E90; electronic control boards cannot reconcile programmed appliance variant parameters.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E101Oven

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Cavity temperature sensor (PT1000) open circuit E101; main controller loses cavity temperature feedback, heating shuts down.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E104Oven

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Multi-point core meat temperature probe fault E104; probe socket shorted or temperature sensing channels inconsistent.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E106Oven

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Tangential cooling fan Hall sensor feedback missing E106; cooling blower fails to turn or tachometer feedback absent.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E115Oven

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Cavity high-limit safety temperature trip E115; oven temperature exceeds maximum safety limit (> 350°C), heating disabled.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E305Oven

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Internal serial bus communication loss E305; display UI console loses data link to base power supply module.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E310Oven

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Pyrolytic door lock mechanism microswitch 1 stuck open E310; door lock motor drives but fails to confirm locked position.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E395Oven

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Pyrolytic door lock motor drive triac short-circuit E395; latch motor continually powered or stalled on mechanical stop.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E396Oven

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Pyrolytic door lock mechanism microswitch 2 high contact resistance E396; unlocked position contact signal degraded (> 1 Ω).

PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose
E0513Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Touch slider interface synchronization timeout E0513; capacitive UI fails handshake with master power module.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E0532Oven

Control panel communication error

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E845Oven

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Combi-steam boiler water level optical sensor calibration failure E845; steam generator cannot verify boiler water level.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
E3000Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Home Connect Wi-Fi communication bus timeout E3000; network communication module fails to handshake with main control board.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E3100Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Zeolith container NTC sensor open circuit E3100; electronic controller cannot monitor zeolite drying bed temperature.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
E3200Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Zeolith regeneration heater auxiliary thermostat open E3200; secondary safety limit switch tripped on drying container.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E5116Oven

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Combi-microwave inverter magnetron heater open circuit E5116; magnetron filament open or high-voltage inverter output missing.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
E5121Oven

Pyrolytic cleaning aborted / Door fault

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E6101Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Drain safety monitoring level anomaly E6101; electronic controller detects incorrect pressure signal during water evacuation.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
E6900Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Main inverter power module hardware fault E6900; internal DC bus voltage regulator or gate driver IC failure.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E7015Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: FlexInduction zone bridging sensor array communication error E7015; Lin-bus packet drop across induction coil nodes.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
E8207Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Induction inverter IGBT desaturation fault E8207; power transistor over-current trip triggered within microseconds.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
E9001Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Low voltage DC power rail mismatch E9001; internal secondary DC voltage rails (+12V / +5V) outside allowable regulation window.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
E9210Dishwasher

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Water hardness ion-exchanger optical sensor anomaly E9210; salt detection photodiode fails to calibrate transparency.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
Er1Oven

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Cavity PT1000 thermocouple sensor disconnected / open circuit Er1; heating program aborted immediately on safety interlock.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
Er2Oven

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Mains connection frequency / phase wiring inversion Er2; power input phase or neutral connection incorrect.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
Er4Oven

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Electronic module compartment overheating Er4; thermal sensor on control board detects ambient temperature > 80°C.

PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose
Er6Oven

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Pyrolytic door lock mechanism fault Er6; lock motor fails to lock or unlock door latch within 30-second timeout.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
Er8Oven

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Combi-microwave generator circuit failure Er8; high-voltage generation absent or microwave inverter trips on safety shutoff.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
F0Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Internal hardware watchdog error F0; central microprocessor on power module triggers safety system shutdown.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
F1Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: LED display driver communication failure F1; touch user interface display controller communication dropout.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
F2Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Cooking zone safety thermal shutdown F2; zone overheated and automatically turned off to protect glass surface.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
F3Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Electronic heat sink over-temperature F3; power module aluminum heatsink thermistor exceeds 85°C limit.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
F4Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Safety time-limit auto shutdown F4; cooking zone has operated continuously without setting adjustments past limit.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
F5Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Control panel overheating warning F5; touch sensors detect excessive heat radiated from hot cookware placed over controls.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
F6Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Touch key continuous activation F6; liquid spillage or object resting on touch panel buttons for > 10 seconds.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
F7Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Zone switching relay failure F7; power relay contact stuck welded or relay driver transistor shorted.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
F8Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Resonant circuit frequency drift F8; induction coil resonant operating frequency outside calibrated window (20–45 kHz).

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
F9Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Auxiliary DC low-voltage rail out of regulation F9; 5V DC logic or 12V DC relay rail out of ±10% tolerance band.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
F16Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Door interlock open fault F16; appliance cannot start wash program because door latch contacts remain unmade.

PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose
F17Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Water inlet timeout alarm F17; appliance fails to reach required wash level within 5 minutes of filling.

Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose
F18Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Draining timeout failure F18; washer fails to evacuate tub wastewater within programmed 6-minute window.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
F19Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Heating timeout error F19; wash water temperature fails to increase by at least 4°C within 15 minutes of heating.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
F20Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Unexpected heating fault F20; heater energized during cold rinse or water heats up without active command.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
F21Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Motor drive / rotation failure F21; drum does not rotate, drive motor fails to turn or accelerate into spin.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
F22Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Wash tub NTC temperature sensor fault F22; thermistor signal open circuit or shorted to ground, cycle runs cold.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
F23Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: AquaStop base float switch activated F23; water leak detected in bottom pan, safety drain pump runs continuously.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
F25Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Turbidity AquaSensor optical fault F25; infrared sensor cannot evaluate rinse water cloudiness or clarity.

Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose
F26Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Analog pressure sensor voltage out of range F26; sensor output signal voltage drops below 0.5V DC or exceeds 3.5V DC.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
F27Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Pressure sensor zero-point calibration drift F27; sensor reports residual water pressure with completely empty tub.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
F28Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Flow sensor impulse signal missing F28; water enters soap dispenser but reed switch flowmeter counts 0 pulses.

Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose
F29Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: No water inflow detected F29; inlet valves energized but pressure sensor detects zero water accumulation.

Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose
F31Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Maximum safety water level exceeded F31; overflow protection trips, inlet valves closed and drain pump energized.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
F34Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Door interlock failed to lock F34; solenoid pulse sent but lock mechanism fails to engage or confirm locked contact.

PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose
F35Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Door interlock failed to unlock F35; door remains locked at cycle end, unlock pulse fails to release mechanism.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
F36Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Door interlock sensing circuit fault F36; feedback line to microcontroller remains inconsistent with lock driver state.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
F37Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: NTC sensor resistance open or high deviation F37; temperature value reads unrealistic cold (<-10°C) during wash.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
F38Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: NTC temperature sensor short-circuit fault F38; sensor lines shorted together or to ground, reading > 120°C.

NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose
F42Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Uncontrolled motor runaway speed error F42; drive motor revs instantly to maximum RPM without speed ramping control.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
F43Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Motor stalled / drum rotation mechanically locked F43; drive motor energized but drum cannot rotate.

Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose
F44Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: No bidirectional motor rotation F44; drum only turns in one direction during wash tumble, reversing relay stuck.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
F47Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Motor inverter power module (IPM) overtemperature F47; thermal sensor on aluminum heatsink trips thermal shutdown.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
F48Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Inverter DC bus undervoltage detected F48; rectified high-voltage DC rail drops below minimum threshold (< 200V DC).

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
F49Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Inverter DC bus overvoltage detected F49; regenerated motor braking energy or AC mains surge exceeds safety limit (> 400V DC).

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
F50Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: 3-phase BLDC motor drive hardware fault F50; inverter bridge reports phase current imbalance or shorted IGBT.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
F57Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Inverter serial D-Bus communication lost F57; main control module loses serial data link to motor inverter module.

3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose
F59Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: 3D Hall acceleration sensor signal missing F59; tub motion sensor fails to report 3-axis vibration data during spin.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
F60Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Flow sensor flow rate out of calibrated bounds F60; discrepancy between flowmeter pulse frequency and pressure rise.

Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose
F61Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Abnormal door lock feedback signal F61; door interlock reports unexpected state changes during high-speed rotation.

PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose
F63Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Functional safety processor watchdog trip F63; internal CPU self-test parity or RAM execution error detected on main PCB.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
F67Washing Machine

Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Configuration variant coding error F67; EEPROM variant data mismatch between user interface and power module.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
Key SymbolOven

Controls are locked, oven won't respond

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
SAFEOven

'SAFE' appears on the display after a power outage

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
Tap SymbolDishwasher

Water supply fault indicator is lit

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
U1Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Severe connection wiring fault U1; 400V line-to-line voltage applied without neutral reference (missing neutral).

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
U2Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Phase imbalance voltage anomaly U2; differential voltage between L1 and L2 lines exceeds 40V under active cooking load.

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
U3Hob

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: DC bus voltage ripple excessive U3; rectified DC link voltage exhibits ripple voltage > 15% under induction load.

PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose
U400Hob

Hob incorrectly connected to mains supply

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose
Flashing Symbol (e.g., '0')Hob

Cooking zone not working, power level flashing

Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose

Siemens — Known Error Codes

CodeAppliancesFault / DiagnosticsRepair InstructionsAction
E73
Tumble Dryer
NTC Temperature Sensor & Thermistor

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Condenser NTC sensor fault E73; temperature sensor on refrigerant condenser coil signal open or short-circuit.

On Siemens tumble dryers: Dislodged sensor clip on condenser copper bend, open lead wire in...

Measure condenser NTC sensor resistance (nominal ~10 kΩ at 25°C, ~3.6 kΩ at 50°C). Check...

Diagnose
E74
Tumble Dryer
NTC Temperature Sensor & Thermistor

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Process air duct NTC sensor error E74; temperature thermistor in front air duct open or shorted.

On Siemens tumble dryers: Fluff accumulation insulating sensor tip, broken wire in door...

Remove front lint filter housing. Clean NTC sensor tip of lint. Measure resistance (nominal...

Diagnose
E75
Tumble Dryer
NTC Temperature Sensor & Thermistor

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Ambient temperature thermistor out of range E75; room temperature sensor reads outside safe operating envelope (< 5°C or > 40°C).

On Siemens tumble dryers: Dryer located in unheated garage or winter porch (< 5°C), direct...

Ensure ambient room temperature is between 10°C and 35°C for heat pump operation. Measure...

Diagnose
E89
Tumble Dryer
Electronic Control Board (PCB) & Bus Communications

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Display UI to power module communication error E89; console display lost serial communication link with base power board.

On Siemens tumble dryers: Disconnected or pinched multiconductor ribbon cable, oxidised...

Remove top lid and front console. Re-seat ribbon cable connectors on both display and power...

Diagnose
E90
Tumble Dryer
Electronic Control Board (PCB) & Bus Communications

Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Variant coding / configuration error E90; electronic control boards cannot reconcile programmed appliance variant parameters.

On Siemens tumble dryers: Replacement PCB installed without model coding, corrupted EEPROM...

Access service program to input correct variant code matching rating plate (E-Nr). If board...

Diagnose
E101
Oven / Microwave
NTC Temperature Sensor & Thermistor

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Cavity temperature sensor (PT1000) open circuit E101; main controller loses cavity temperature feedback, heating shuts down.

On Siemens ovens: Platinum PT1000 sensor wire snapped inside rear insulation blanket,...

Disconnect power. Remove rear cover panel. Measure PT1000 resistance across sensor plug...

Diagnose
E104
Oven / Microwave
General System & Mechanical Integration

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Multi-point core meat temperature probe fault E104; probe socket shorted or temperature sensing channels inconsistent.

On Siemens ovens: Grease/moisture ingress into side cavity jack socket, damaged multi-core...

Unplug core probe. Inspect internal cavity jack socket and clean with electrical solvent....

Diagnose
E106
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Tangential cooling fan Hall sensor feedback missing E106; cooling blower fails to turn or tachometer feedback absent.

On Siemens ovens: Jammed tangential cross-flow blower wheel, open motor winding (~120–160...

Disconnect mains. Remove top panel. Ensure cross-flow fan spins smoothly. Measure motor...

Diagnose
E115
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Cavity high-limit safety temperature trip E115; oven temperature exceeds maximum safety limit (> 350°C), heating disabled.

On Siemens ovens: Welded heating element relay on power PCB keeping elements continuously...

Allow oven to cool completely. Test power board relays for welded contacts when...

Diagnose
E305
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Internal serial bus communication loss E305; display UI console loses data link to base power supply module.

On Siemens ovens: Disconnected multiconductor flat ribbon harness, oxidised connector...

Disconnect mains. Re-seat communication ribbon harness firmly between display board and...

Diagnose
E310
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Pyrolytic door lock mechanism microswitch 1 stuck open E310; door lock motor drives but fails to confirm locked position.

On Siemens ovens: Worn latch cam lever, broken internal spring in door lock mechanism, or...

Disconnect power. Remove top lid to access door lock motor above cavity. Test microswitch 1...

Diagnose
E395
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Pyrolytic door lock motor drive triac short-circuit E395; latch motor continually powered or stalled on mechanical stop.

On Siemens ovens: Shorted synchronous motor winding drawing excessive current, or SMD...

Measure pyrolytic lock motor winding resistance (nominal ~1.8–2.2 kΩ; shorted if < 100 Ω)....

Diagnose
E396
Oven / Microwave
Door Lock Mechanism & Safety Interlock

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Pyrolytic door lock mechanism microswitch 2 high contact resistance E396; unlocked position contact signal degraded (> 1 Ω).

On Siemens ovens: Carbonized or pitted contacts on microswitch 2, grease ingress into...

Access door lock unit on top of cavity. Measure contact resistance across microswitch 2...

Diagnose
E0513
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Touch slider interface synchronization timeout E0513; capacitive UI fails handshake with master power module.

On Siemens hobs: Clock jitter on UI communication line, damaged noise suppression filter...

Check wiring loom between touch slider and power module for continuity and electromagnetic...

Diagnose
E0532
Oven / Microwave
Electronic Control Board (PCB) & Bus Communications

Control panel communication error

A communication fault has occurred between the main control board and the user interface.

Disconnect the oven from the power supply for at least 30 minutes to reset the electronics....

Diagnose
E845
Oven / Microwave
Water Level Pressure Switch & Air Dome

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Combi-steam boiler water level optical sensor calibration failure E845; steam generator cannot verify boiler water level.

On Siemens ovens: Heavy lime scale coating optical refraction prism inside steam generator,...

Run automatic oven descaling program with recommended descaling liquid. Remove boiler unit...

Diagnose
E3000
Dishwasher
Electronic Control Board (PCB) & Bus Communications

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Home Connect Wi-Fi communication bus timeout E3000; network communication module fails to handshake with main control board.

On Siemens dishwashers: Firmware update corruption on Wi-Fi module, intermittent ribbon...

Power cycle appliance at breaker for 2 minutes. Inspect internal ribbon harness linking...

Diagnose
E3100
Dishwasher
NTC Temperature Sensor & Thermistor

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Zeolith container NTC sensor open circuit E3100; electronic controller cannot monitor zeolite drying bed temperature.

On Siemens dishwashers: Broken lead wire to Zeolith container NTC sensor, corrosion on...

Measure Zeolith NTC sensor resistance across terminals (nominal ~10 kΩ at 25°C). Inspect...

Diagnose
E3200
Dishwasher
Heating Element, Thermostat & Safety Fuse

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Zeolith regeneration heater auxiliary thermostat open E3200; secondary safety limit switch tripped on drying container.

On Siemens dishwashers: Air circulation blower failed while Zeolith heater was energized,...

Inspect Zeolith blower motor and verify free rotation. Test continuity of auxiliary thermal...

Diagnose
E5116
Oven / Microwave
Heating Element, Thermostat & Safety Fuse

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Combi-microwave inverter magnetron heater open circuit E5116; magnetron filament open or high-voltage inverter output missing.

On Siemens ovens: Burned-out filament in 2M261 magnetron tube (nominal < 0.2 Ω), blown...

DANGER: Disconnect mains and discharge high-voltage capacitor. Measure magnetron filament...

Diagnose
E5121
Oven / Microwave
Drive Motor, Inverter & Tachometer Sensor

Pyrolytic cleaning aborted / Door fault

There is a fault with the door contact switch or the door locking motor during a pyrolytic...

Allow the oven to cool completely. Power cycle the appliance. If the fault persists during...

Diagnose
E6101
Dishwasher
Drainage System & Drain Pump

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Drain safety monitoring level anomaly E6101; electronic controller detects incorrect pressure signal during water evacuation.

On Siemens dishwashers: Clogged pressure chamber air hose in sump, non-return flap stuck...

Clean sump pressure transducer chamber using warm water syringe. Inspect rubber non-return...

Diagnose
E6900
Dishwasher
Drive Motor, Inverter & Tachometer Sensor

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Main inverter power module hardware fault E6900; internal DC bus voltage regulator or gate driver IC failure.

On Siemens dishwashers: Blown switch-mode power supply (SMPS) controller chip, failed DC...

Disconnect mains power. Remove and inspect power module located in lower base. Check for...

Diagnose
E7015
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: FlexInduction zone bridging sensor array communication error E7015; Lin-bus packet drop across induction coil nodes.

On Siemens hobs: Interrupted Lin-bus data harness between left and right coil arrays,...

Disconnect power. Verify 12V supply and single-wire Lin-bus continuity (< 1 Ω) between all...

Diagnose
E8207
Hob / Cooktop
Drive Motor, Inverter & Tachometer Sensor

Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Induction inverter IGBT desaturation fault E8207; power transistor over-current trip triggered within microseconds.

On Siemens hobs: Short circuit inside induction heating coil windings, damaged IGBT driver...

Isolate hob from mains. Measure coil winding resistance (~0.3–0.6 Ω, never 0.0 Ω). Test...

Diagnose
E9001
Dishwasher
General System & Mechanical Integration

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Low voltage DC power rail mismatch E9001; internal secondary DC voltage rails (+12V / +5V) outside allowable regulation window.

On Siemens dishwashers: Dried electrolytic filter capacitors in low-voltage section,...

Disconnect sensor connectors one by one to isolate shorted rail. Measure +5V DC and +12V DC...

Diagnose
E9210
Dishwasher
General System & Mechanical Integration

Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Water hardness ion-exchanger optical sensor anomaly E9210; salt detection photodiode fails to calibrate transparency.

On Siemens dishwashers: Air bubbles or salt residue crust covering optical sensor lenses on...

Stir salt container with wooden spoon to dislodge salt bridges and air bubbles. Run a rinse...

Diagnose
Er1
Oven / Microwave
NTC Temperature Sensor & Thermistor

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Cavity PT1000 thermocouple sensor disconnected / open circuit Er1; heating program aborted immediately on safety interlock.

On Siemens ovens: Sensor harness unplugged from rear of cavity, damaged silicone wire...

Check sensor plug behind rear backplate. Measure PT1000 resistance (nominal 1000 Ω at 0°C,...

Diagnose
Er2
Oven / Microwave
General System & Mechanical Integration

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Mains connection frequency / phase wiring inversion Er2; power input phase or neutral connection incorrect.

On Siemens ovens: Neutral and phase wire swapped at terminal block, missing copper jumper...

Verify wiring at rear terminal block with multimeter (L to N must be 230V AC; L to PE must...

Diagnose
Er4
Oven / Microwave
Door Lock Mechanism & Safety Interlock

Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Electronic module compartment overheating Er4; thermal sensor on control board detects ambient temperature > 80°C.

On Siemens ovens: Tangential cooling fan not operating, blocked ventilation slots above...

Allow oven to cool down with door open. Verify tangential cooling fan runs when power is...

Diagnose
← Previous PagePage 5 of 7 (202 results)Next Page →

Siemens — Complete Error Code Catalog

202 Verified Error Codes

Server-side index of all verified manufacturer error codes for technicians and automated crawlers.

Siemens — Dishwasher39

E01E02E03E04E05E06E07E08E09E10E11E12E13E14E15E16E17E18E19E20E21E22E23E24E25E26E27E28E29E30E31E3000E3100E3200E6101E6900E9001E9210Tap Symbol

Siemens — Washing Machine65

E16E17E18E19E20E21E22E23E25E26E27E28E29E31E32E34E35E36E37E38E42E43E44E47E48E49E50E57E59E60E61E63E67F16F17F18F19F20F21F22F23F25F26F27F28F29F31F34F35F36F37F38F42F43F44F47F48F49F50F57F59F60F61F63F67

Siemens — Tumble Dryer26

E01E03E05E06E08E09E15E16E23E29E32E36E51E52E53E54E55E56E63E71E72E73E74E75E89E90

Siemens — Oven / Microwave21

E005E011E101E104E106E115E305E310E395E396E0532E845E5116E5121Er1Er2Er4Er6Er8Key SymbolSAFE

Siemens — Hob / Cooktop39

d0d1d2d3d4d5d6d7d8d9dEE0E1E2E3E4E5E6E7E8E9E0513E7015E8207F0F1F2F3F4F5F6F7F8F9U1U2U3U400Flashing Symbol (e.g., '0')

Siemens — Refrigerator / Freezer12

ALDemo ModeE01E02E03E04E05E10E11E15E20E21

Need Help? Call a Certified Technician

Our official certified partners service Siemens appliances in your area.

Electroassistance (Switzerland)Appliance Care UK (United Kingdom)
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Terms of Service Privacy Policy