AL Refrigerator Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: High temperature cavity alarm AL; freezer temperature has risen above critical threshold of -9°C for over 60 minutes.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose d0 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Showroom demo mode active d0; displays and touch sliders illuminate and respond but power elements do not heat.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose d1 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Front left cooking zone demo test locked d1; front left inverter locked in display simulation loop.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose d2 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Rear left cooking zone demo test locked d2; rear left induction channel disabled in demo simulation mode.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose d3 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Center / rear right cooking zone demo test locked d3; zone controller in exhibition simulation state.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose d4 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Front right cooking zone demo test locked d4; front right power stage disabled in store demonstration mode.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose d5 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: FlexInduction bridging relay check state d5; induction coil coupling relays engaged in diagnostic cycle.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose d6 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Forced high-speed cooling fan test mode active d6; fan runs continuously at maximum RPM for thermal evaluation.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose d7 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Mains voltage telemetry feedback display d7; digital voltmeter diagnostic screen showing live input AC voltage.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose d8 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Touch slider sensitivity calibration mode d8; user interface enters capacitive touch gain tuning display.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose d9 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Factory end-of-line (EOL) test loop active d9; automated manufacturing test routine repeating test steps.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose dE Hob Hob is in demonstration mode
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose Demo Mode Refrigerator Lights and display work but appliance does not cool
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E0 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Control unit configuration error E0; touch module EEPROM parameter mismatch prevents zone activation.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose E01 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Critical power module failure E01; heating circuit relay contacts open or welded on the main control board.
Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose E01 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Process air circulation blockage E01; lint filter or air channel clogged, stopping drying cycle.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E01 Refrigerator Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: Fridge compartment temperature sensor failure E01; fresh food zone NTC sensor circuit open or shorted.
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose E1 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Internal bus communication failure E1; user interface loses serial data link with induction power generator.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose E02 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Auxiliary heating relay malfunction E02; secondary safety relay on power PCB fails to close during water heating phase.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose E02 Refrigerator Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: Evaporator defrost temperature sensor fault E02; defrost termination NTC sensor out of range or open circuit.
Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose E2 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Induction coil temperature sensor over-temperature E2; coil NTC thermistor registers > 240°C or short circuit.
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose E03 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Auxiliary heating relay circuit discrepancy E03; microprocessor detects inconsistent contact state across heating relays.
Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose E03 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Maximum drying cycle time limit exceeded E03; laundry remains damp after programmed 4-hour cycle timeout.
Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose E03 Refrigerator Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: Chiller / VitaFresh compartment sensor fault E03; meat/fish preservation drawer NTC registers invalid readings.
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose E3 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Mains over-voltage detected E3; supply voltage on phase L1/L2 exceeds safe threshold of 275V AC.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E04 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Water switch diverter position feedback failure E04; upper/lower spray arm alternator disc position unknown.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E04 Refrigerator Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: Ambient room temperature sensor fault E04; external temperature NTC located at top hinge cover disconnected or open.
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose E4 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Mains under-voltage detected E4; AC line voltage drops below 185V AC under load during active heating.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E005 Oven Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Power interlock safety relay failure E005; safety relay on power PCB fails to close power circuit to heating elements.
Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose E05 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Water switch motor triac short-circuit E05; electronic controller cannot regulate water diverter valve motor.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E05 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Condensate drain pump triac / circuit failure E05; water accumulated during drying cannot be pumped into collection tank.
Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose E05 Refrigerator Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: Freezer compartment air temperature sensor fault E05; freezer interior cavity NTC sensor circuit open or shorted.
Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose E5 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Left induction generator module fault E5; power board phase L1 fails internal self-test or IGBT gate driver trip.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose E06 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Door Hall sensor latch anomaly E06; control unit detects open door signal or invalid magnetic reed feedback during cycle.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E06 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Heating element power relay fault E06; control module relay contacts fail to switch power to heater assembly.
Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose E6 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Right induction generator module fault E6; power board phase L2 fails internal diagnostic cycle.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E07 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Zeolith drying fan / airflow restriction E07; zeolite air circulation blower motor blocked or thermistor out of spec.
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose E7 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Cooling fan malfunction E7; tachometer feedback signal missing or fan motor speed falls below 500 RPM.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E08 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Low water level in sump during heating E08; heat pump detects insufficient water coverage over heating ring.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose E08 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Heat pump auxiliary relay / defrost fault E08; heat pump evaporator icing up or defrost cycle fails to initiate.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E8 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Cookware detection fault E8; resonant circuit fails to establish stable magnetic coupling with pan bottom.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E09 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Heating circuit open failure E09; heat pump heating element open circuit, water remains cold throughout cycle.
Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose E09 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Heating circuit open circuit error E09; heating element coil open or thermal fuse blown, drum blows cold air.
Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose E9 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Touch panel capacitive calibration failure E9; touch sensor controller detects finger contact during system boot sequence.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E10 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Scale build-up on heating element E10; reduced heat transfer efficiency and slow water temperature rise.
Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose E10 Refrigerator Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: Compressor inverter communication failure E10; master control board loses serial telemetry link with inverter PCB.
Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose E011 Oven Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Stuck capacitive touch key sensor E011; touch control surface senses permanent touch activation for > 10 seconds.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E11 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: NTC temperature sensor fault E11; thermistor resistance signal open, shorted, or outside calibration limits.
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose E11 Refrigerator Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: Display user interface communication error E11; door display panel fails serial handshake with power electronics.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose E12 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Severe lime scale build-up warning E12; thermal sensors detect heat retention on heating ring during drain.
Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose E13 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: High water inlet temperature E13; intake water exceeds maximum design temperature limit (> 75°C).
Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose E14 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Flowmeter turbine impulse signal missing E14; water fills but reed switch sensor fails to count pulses.
Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose E15 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: AquaStop safety flood protection triggered E15; polystyrene float switch in base tray activated, drain pump runs continuously.
Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose E15 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Safety high-limit thermostat tripped E15; heater housing overtemperature switch opened, shutting off heating coils.
Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose E15 Refrigerator Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: Defrost heater system malfunction E15; evaporator heating element fails to melt frost within maximum defrost duration.
Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose E16 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Uncontrolled water inflow / solenoid valve leak E16; water continually enters tub even when inlet valve is de-energized.
Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose E16 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Exhaust air temperature safety cutout E16; exhaust duct sensor exceeds safety temperature limit (> 95°C).
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E16 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Door interlock open fault E16; appliance cannot start wash program because door latch contacts remain unmade.
PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose E17 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: High water inlet pressure / overflow risk E17; flow rate into heat exchanger exceeds maximum allowable speed.
Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose E17 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Water inlet timeout alarm E17; appliance fails to reach required wash level within 5 minutes of filling.
Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose E18 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Low water flow inlet timeout E18; minimum water volume not achieved within programmed filling time window.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E18 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Draining timeout failure E18; washer fails to evacuate tub wastewater within programmed 6-minute window.
Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose E19 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Dispenser actuator / heat exchanger drainage valve coil failure E19; solenoid coil open circuit or triac blown.
Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose E19 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Heating timeout error E19; wash water temperature fails to increase by at least 4°C within 15 minutes of heating.
Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose E20 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Circulation pump BLDC winding resistance fault E20; phase impedance imbalance or open coil detected by inverter.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E20 Refrigerator Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: Inverter compressor drive failure E20; compressor fails to start, stalls under differential pressure, or draws excessive current.
Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose E20 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Unexpected heating fault E20; heater energized during cold rinse or water heats up without active command.
Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose E21 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Circulation pump motor jammed / blocked impeller E21; motor fails to start, excessive current draw shuts down inverter.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E21 Refrigerator Siemens iQ500 / iQ700 studioLine hyperFresh premium 0°C & noFrost: Evaporator circulation fan motor failure E21; no-frost cold air circulation blower stopped or tachometer feedback missing.
Compressor Motor Windings (Run/Start) & Defrost Heater
Refrigeration Compressor, Defrost Heater & PTC Relay
Diagnose E21 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Motor drive / rotation failure E21; drum does not rotate, drive motor fails to turn or accelerate into spin.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E22 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Sump filter blocked / residual water accumulation E22; fine mesh screen clogged by grease and food residues.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E22 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Wash tub NTC temperature sensor fault E22; thermistor signal open circuit or shorted to ground, cycle runs cold.
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose E23 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Drain pump winding resistance error E23; inverter reports open circuit, phase short, or coil defect in drain motor.
Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose E23 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Condensate container overflow / float switch active E23; sump reservoir full, cycle pauses with water tank warning.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E23 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: AquaStop base float switch activated E23; water leak detected in bottom pan, safety drain pump runs continuously.
Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose E24 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Drain hose obstruction / siphon block E24; appliance fails to expel waste water, pump stops after initial 1-minute test.
Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose E25 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Drain pump impeller locked / pump cover missing E25; wastewater cannot be pumped out, standing water in tub bottom.
Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose E25 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Turbidity AquaSensor optical fault E25; infrared sensor cannot evaluate rinse water cloudiness or clarity.
Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose E26 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Water switch diverter valve mechanical jam E26; rotary distributor disc cannot complete rotation between spray arms.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E26 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Analog pressure sensor voltage out of range E26; sensor output signal voltage drops below 0.5V DC or exceeds 3.5V DC.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose E27 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Mains undervoltage detected E27; AC supply voltage drops below minimum operating threshold (< 190V AC).
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E27 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Pressure sensor zero-point calibration drift E27; sensor reports residual water pressure with completely empty tub.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E28 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Turbidity AquaSensor optical calibration fault E28; phototransistor cannot calibrate wash water clarity.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E28 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Flow sensor impulse signal missing E28; water enters soap dispenser but reed switch flowmeter counts 0 pulses.
Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose E29 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Mains supply frequency out of tolerance E29; AC grid frequency deviates beyond acceptable 50 Hz / 60 Hz window.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E29 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Condensate drain siphon / line clogged E29; self-cleaning condenser flush line or external drain hose obstructed.
Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose E29 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: No water inflow detected E29; inlet valves energized but pressure sensor detects zero water accumulation.
Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose E30 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Mains overvoltage detected E30; supply line voltage exceeds upper operating safety limit (> 265V AC).
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E31 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Zeolith heat pump overheating safety trip E31; thermal cutout on drying container activated.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E31 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Maximum safety water level exceeded E31; overflow protection trips, inlet valves closed and drain pump energized.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose E32 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Moisture sensor conductivity circuit anomaly E32; sensor electrode strips report open circuit or permanent wet state.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E32 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Drum unbalanced load distribution warning E32; appliance aborts final spin or reduces speed to prevent vibration damage.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E34 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Door interlock failed to lock E34; solenoid pulse sent but lock mechanism fails to engage or confirm locked contact.
PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose E35 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Door interlock failed to unlock E35; door remains locked at cycle end, unlock pulse fails to release mechanism.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose E36 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Door interlock switch open during program E36; door catch pops open or microswitch contacts bounce during rotation.
PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose E36 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Door interlock sensing circuit fault E36; feedback line to microcontroller remains inconsistent with lock driver state.
Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose E37 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: NTC sensor resistance open or high deviation E37; temperature value reads unrealistic cold (<-10°C) during wash.
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose E38 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: NTC temperature sensor short-circuit fault E38; sensor lines shorted together or to ground, reading > 120°C.
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose E42 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Uncontrolled motor runaway speed error E42; drive motor revs instantly to maximum RPM without speed ramping control.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E43 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Motor stalled / drum rotation mechanically locked E43; drive motor energized but drum cannot rotate.
Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose E44 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: No bidirectional motor rotation E44; drum only turns in one direction during wash tumble, reversing relay stuck.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E47 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Motor inverter power module (IPM) overtemperature E47; thermal sensor on aluminum heatsink trips thermal shutdown.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E48 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Inverter DC bus undervoltage detected E48; rectified high-voltage DC rail drops below minimum threshold (< 200V DC).
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E49 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Inverter DC bus overvoltage detected E49; regenerated motor braking energy or AC mains surge exceeds safety limit (> 400V DC).
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E50 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: 3-phase BLDC motor drive hardware fault E50; inverter bridge reports phase current imbalance or shorted IGBT.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E51 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Motor inverter IPM short circuit E51; drive motor / compressor inverter trips instantly on overcurrent.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E52 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Drum drive motor inverter undervoltage E52; DC bus supply voltage drops below minimum operating threshold (< 200V DC).
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E53 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Drum drive motor inverter overvoltage E53; DC bus voltage exceeds upper safety limit (> 400V DC).
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E54 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Heat pump compressor inverter phase imbalance E54; current asymmetry detected across compressor 3-phase motor.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E55 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Compressor rotor locked / stalled E55; heat pump compressor fails to turn over, inverter trips on locked-rotor current.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E56 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Inverter heatsink thermal sensor overtemperature E56; power board temperature exceeds safe operating threshold (> 85°C).
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E57 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Inverter serial D-Bus communication lost E57; main control module loses serial data link to motor inverter module.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E59 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: 3D Hall acceleration sensor signal missing E59; tub motion sensor fails to report 3-axis vibration data during spin.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E60 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Flow sensor flow rate out of calibrated bounds E60; discrepancy between flowmeter pulse frequency and pressure rise.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose E61 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Abnormal door lock feedback signal E61; door interlock reports unexpected state changes during high-speed rotation.
PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose E63 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Microcontroller safety watchdog fault E63; internal microprocessor registers report execution error, halting cycle.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose E63 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Functional safety processor watchdog trip E63; internal CPU self-test parity or RAM execution error detected on main PCB.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose E67 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Configuration variant coding error E67; EEPROM variant data mismatch between user interface and power module.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose E71 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Compressor discharge temperature NTC sensor error E71; sensor resistance open, shorted, or out of calibration range.
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose E72 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Evaporator NTC defrost sensor failure E72; temperature sensor on heat pump evaporator coil open or shorted.
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose E73 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Condenser NTC sensor fault E73; temperature sensor on refrigerant condenser coil signal open or short-circuit.
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose E74 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Process air duct NTC sensor error E74; temperature thermistor in front air duct open or shorted.
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose E75 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Ambient temperature thermistor out of range E75; room temperature sensor reads outside safe operating envelope (< 5°C or > 40°C).
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose E89 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Display UI to power module communication error E89; console display lost serial communication link with base power board.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose E90 Tumble Dryer Siemens iQ500 / iQ700 / iQ800 studioLine selfCleaning condenser & sensoFresh: Variant coding / configuration error E90; electronic control boards cannot reconcile programmed appliance variant parameters.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose E101 Oven Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Cavity temperature sensor (PT1000) open circuit E101; main controller loses cavity temperature feedback, heating shuts down.
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose E104 Oven Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Multi-point core meat temperature probe fault E104; probe socket shorted or temperature sensing channels inconsistent.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E106 Oven Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Tangential cooling fan Hall sensor feedback missing E106; cooling blower fails to turn or tachometer feedback absent.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E115 Oven Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Cavity high-limit safety temperature trip E115; oven temperature exceeds maximum safety limit (> 350°C), heating disabled.
Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose E305 Oven Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Internal serial bus communication loss E305; display UI console loses data link to base power supply module.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose E310 Oven Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Pyrolytic door lock mechanism microswitch 1 stuck open E310; door lock motor drives but fails to confirm locked position.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E395 Oven Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Pyrolytic door lock motor drive triac short-circuit E395; latch motor continually powered or stalled on mechanical stop.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E396 Oven Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Pyrolytic door lock mechanism microswitch 2 high contact resistance E396; unlocked position contact signal degraded (> 1 Ω).
PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose E0513 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Touch slider interface synchronization timeout E0513; capacitive UI fails handshake with master power module.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose E0532 Oven Control panel communication error
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose E845 Oven Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Combi-steam boiler water level optical sensor calibration failure E845; steam generator cannot verify boiler water level.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose E3000 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Home Connect Wi-Fi communication bus timeout E3000; network communication module fails to handshake with main control board.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose E3100 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Zeolith container NTC sensor open circuit E3100; electronic controller cannot monitor zeolite drying bed temperature.
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose E3200 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Zeolith regeneration heater auxiliary thermostat open E3200; secondary safety limit switch tripped on drying container.
Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose E5116 Oven Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Combi-microwave inverter magnetron heater open circuit E5116; magnetron filament open or high-voltage inverter output missing.
Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose E5121 Oven Pyrolytic cleaning aborted / Door fault
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E6101 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Drain safety monitoring level anomaly E6101; electronic controller detects incorrect pressure signal during water evacuation.
Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose E6900 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Main inverter power module hardware fault E6900; internal DC bus voltage regulator or gate driver IC failure.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E7015 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: FlexInduction zone bridging sensor array communication error E7015; Lin-bus packet drop across induction coil nodes.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose E8207 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Induction inverter IGBT desaturation fault E8207; power transistor over-current trip triggered within microseconds.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose E9001 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Low voltage DC power rail mismatch E9001; internal secondary DC voltage rails (+12V / +5V) outside allowable regulation window.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose E9210 Dishwasher Siemens iQ300 / iQ500 / iQ700 / iQ800 studioLine Zeolith & varioSpeed Plus: Water hardness ion-exchanger optical sensor anomaly E9210; salt detection photodiode fails to calibrate transparency.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose Er1 Oven Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Cavity PT1000 thermocouple sensor disconnected / open circuit Er1; heating program aborted immediately on safety interlock.
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose Er2 Oven Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Mains connection frequency / phase wiring inversion Er2; power input phase or neutral connection incorrect.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose Er4 Oven Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Electronic module compartment overheating Er4; thermal sensor on control board detects ambient temperature > 80°C.
PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose Er6 Oven Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Pyrolytic door lock mechanism fault Er6; lock motor fails to lock or unlock door latch within 30-second timeout.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose Er8 Oven Siemens iQ500 / iQ700 studioLine activeClean & pulseSteam TFT Touchdisplay Plus: Combi-microwave generator circuit failure Er8; high-voltage generation absent or microwave inverter trips on safety shutoff.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose F0 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Internal hardware watchdog error F0; central microprocessor on power module triggers safety system shutdown.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose F1 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: LED display driver communication failure F1; touch user interface display controller communication dropout.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose F2 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Cooking zone safety thermal shutdown F2; zone overheated and automatically turned off to protect glass surface.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose F3 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Electronic heat sink over-temperature F3; power module aluminum heatsink thermistor exceeds 85°C limit.
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose F4 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Safety time-limit auto shutdown F4; cooking zone has operated continuously without setting adjustments past limit.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose F5 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Control panel overheating warning F5; touch sensors detect excessive heat radiated from hot cookware placed over controls.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose F6 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Touch key continuous activation F6; liquid spillage or object resting on touch panel buttons for > 10 seconds.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose F7 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Zone switching relay failure F7; power relay contact stuck welded or relay driver transistor shorted.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose F8 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Resonant circuit frequency drift F8; induction coil resonant operating frequency outside calibrated window (20–45 kHz).
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose F9 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Auxiliary DC low-voltage rail out of regulation F9; 5V DC logic or 12V DC relay rail out of ±10% tolerance band.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose F16 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Door interlock open fault F16; appliance cannot start wash program because door latch contacts remain unmade.
PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose F17 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Water inlet timeout alarm F17; appliance fails to reach required wash level within 5 minutes of filling.
Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose F18 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Draining timeout failure F18; washer fails to evacuate tub wastewater within programmed 6-minute window.
Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose F19 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Heating timeout error F19; wash water temperature fails to increase by at least 4°C within 15 minutes of heating.
Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose F20 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Unexpected heating fault F20; heater energized during cold rinse or water heats up without active command.
Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose F21 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Motor drive / rotation failure F21; drum does not rotate, drive motor fails to turn or accelerate into spin.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose F22 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Wash tub NTC temperature sensor fault F22; thermistor signal open circuit or shorted to ground, cycle runs cold.
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose F23 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: AquaStop base float switch activated F23; water leak detected in bottom pan, safety drain pump runs continuously.
Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose F25 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Turbidity AquaSensor optical fault F25; infrared sensor cannot evaluate rinse water cloudiness or clarity.
Drain Pump Motor Stator Coils
Drainage System & Drain Pump
Diagnose F26 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Analog pressure sensor voltage out of range F26; sensor output signal voltage drops below 0.5V DC or exceeds 3.5V DC.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose F27 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Pressure sensor zero-point calibration drift F27; sensor reports residual water pressure with completely empty tub.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose F28 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Flow sensor impulse signal missing F28; water enters soap dispenser but reed switch flowmeter counts 0 pulses.
Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose F29 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: No water inflow detected F29; inlet valves energized but pressure sensor detects zero water accumulation.
Solenoid Valve Coil / Aquastop Pneumatic Valve
Water Inlet Valve, Aquastop & Flowmeter
Diagnose F31 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Maximum safety water level exceeded F31; overflow protection trips, inlet valves closed and drain pump energized.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose F34 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Door interlock failed to lock F34; solenoid pulse sent but lock mechanism fails to engage or confirm locked contact.
PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose F35 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Door interlock failed to unlock F35; door remains locked at cycle end, unlock pulse fails to release mechanism.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose F36 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Door interlock sensing circuit fault F36; feedback line to microcontroller remains inconsistent with lock driver state.
Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose F37 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: NTC sensor resistance open or high deviation F37; temperature value reads unrealistic cold (<-10°C) during wash.
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose F38 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: NTC temperature sensor short-circuit fault F38; sensor lines shorted together or to ground, reading > 120°C.
NTC Temperature Sensor Probe (Thermistor)
NTC Temperature Sensor & Thermistor
Diagnose F42 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Uncontrolled motor runaway speed error F42; drive motor revs instantly to maximum RPM without speed ramping control.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose F43 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Motor stalled / drum rotation mechanically locked F43; drive motor energized but drum cannot rotate.
Immersion / Air Heating Element & Klixon Thermostat
Heating Element, Thermostat & Safety Fuse
Diagnose F44 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: No bidirectional motor rotation F44; drum only turns in one direction during wash tumble, reversing relay stuck.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose F47 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Motor inverter power module (IPM) overtemperature F47; thermal sensor on aluminum heatsink trips thermal shutdown.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose F48 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Inverter DC bus undervoltage detected F48; rectified high-voltage DC rail drops below minimum threshold (< 200V DC).
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose F49 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Inverter DC bus overvoltage detected F49; regenerated motor braking energy or AC mains surge exceeds safety limit (> 400V DC).
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose F50 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: 3-phase BLDC motor drive hardware fault F50; inverter bridge reports phase current imbalance or shorted IGBT.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose F57 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Inverter serial D-Bus communication lost F57; main control module loses serial data link to motor inverter module.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Drive Motor, Inverter & Tachometer Sensor
Diagnose F59 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: 3D Hall acceleration sensor signal missing F59; tub motion sensor fails to report 3-axis vibration data during spin.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose F60 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Flow sensor flow rate out of calibrated bounds F60; discrepancy between flowmeter pulse frequency and pressure rise.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Water Level Pressure Switch & Air Dome
Diagnose F61 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Abnormal door lock feedback signal F61; door interlock reports unexpected state changes during high-speed rotation.
PTC Heater Pellet / Pulse Solenoid / Microswitch Contacts
Door Lock Mechanism & Safety Interlock
Diagnose F63 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Functional safety processor watchdog trip F63; internal CPU self-test parity or RAM execution error detected on main PCB.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose F67 Washing Machine Siemens iQ500 / iQ700 / iQ800 studioLine iQdrive & i-Dos intelligent dosing: Configuration variant coding error F67; EEPROM variant data mismatch between user interface and power module.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose Key Symbol Oven Controls are locked, oven won't respond
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose SAFE Oven 'SAFE' appears on the display after a power outage
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose Tap Symbol Dishwasher Water supply fault indicator is lit
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose U1 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Severe connection wiring fault U1; 400V line-to-line voltage applied without neutral reference (missing neutral).
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose U2 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: Phase imbalance voltage anomaly U2; differential voltage between L1 and L2 lines exceeds 40V under active cooking load.
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose U3 Hob Siemens iQ700 / iQ800 studioLine flexInduction & freeInduction Plus: DC bus voltage ripple excessive U3; rectified DC link voltage exhibits ripple voltage > 15% under induction load.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Diagnose U400 Hob Hob incorrectly connected to mains supply
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose Flashing Symbol (e.g., '0') Hob Cooking zone not working, power level flashing
Protective Earth Bonding & Incoming Mains Voltage
General System & Mechanical Integration
Diagnose