Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Critical freezer high temperature alarm AL01; freezer compartment temperature has risen above safe threshold of -9°C.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Water dispenser filter expiration / flow timeout alarm AL02; water purification filter cartridge life limit or fill slow rate detected.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water filling timeout alarm AL05; wash tank does not fill to operating level within program timeout limit.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Interface display communication error E0; temperature control panel loses serial link with master power PCB.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water fill solenoid valve circuit fault E01; power board detects open circuit across inlet solenoid coil.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Door interlock error E01; appliance refuses to commence wash cycle because the door latch contact is not verified.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water inlet fill failure E1; appliance detects no incoming water flow into sump after opening fill valve.
Haier I-Move Series / Multi Switch Precision Induction Hob: Touch sensor zone covered by object or liquid E1; continuous conductive activation detected on control glass for >10 seconds.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Refrigerator compartment temperature sensor fault E1; fresh food section thermistor circuit open or shorted.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Fill meter pulse count error E02; turbine sensor signals water fill but pulse frequency is erratic or dropping out.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Process air duct NTC sensor error E02; thermistor signal indicates circuit open, short, or temperature out of operating range.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water inlet fill timeout E02; tub does not reach the minimum operating water level within 210 seconds of valve energization.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier I-Move Series / Multi Switch Precision Induction Hob: Induction cooking zone coil overheat E2; NTC temperature sensor beneath ceramic glass detects temperature exceeding 240°C.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Freezer compartment temperature sensor malfunction E2; low-temperature NTC thermistor circuit open or short-circuited.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Door / lid lock failure E2; machine does not engage lock solenoid or detects door open during cycle start.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Maximum drying cycle time exceeded E03; machine aborts cycle after running for 210 minutes without laundry reaching target dryness.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water evacuation fault E03; machine aborts cycle with water remaining in drum after 180 seconds of drain pump operation.
Haier I-Move Series / Multi Switch Precision Induction Hob: Induction power board IGBT heatsink overtemperature E3; power transistor heatsink temperature exceeds 95°C safety shutoff.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Evaporator defrost temperature sensor fault E3; defrost termination NTC thermistor out of calibrated ohmic range.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier I-Move Series / Multi Switch Precision Induction Hob: Induction coil temperature sensor circuit fault E4; coil center NTC thermistor reads open circuit or shorted.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water fill timeout E4; water does not reach target level within 8 minutes of starting fill cycle.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water temperature sensor measurement anomaly E05; NTC probe signal resistance indicates temperature below -5°C or above 90°C.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Drum motor drive failure E06; motor hums but fails to rotate the drum, or drive motor trips on thermal overload.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Humidity sensor communication error E6; crisper drawer moisture and relative humidity module signal loss.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Drum rotation sensor speed feedback missing E07; controller does not detect drum movement during program run.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor drive tachometer fault E07; drum does not rotate or motor starts at uncontrolled high speed then immediately stops.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Wash circulation pump failure E7; motor does not rotate, tachometer feedback is absent, or run capacitor is open.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Move Series / Multi Switch Precision Induction Hob: Cooling fan failure E7; internal induction generator cooling fan motor stalled, disconnected, or zero RPM feedback.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Automatic ice maker mold temperature sensor error E7; ice tray thermistor reading out of bounds during freezing cycle.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor drive inverter module overcurrent E7; drive electronics trip on thermal overload or excessive current draw.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Flow-through heater circuit open E08; water temperature does not increase during heated wash stage.
Immersion / Air Heating Element & Klixon Thermostat
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Automatic ice maker ejection motor stall E8; ice tray harvest mechanism fails to complete home position cycle within 3 minutes.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Drum motor drive semiconductor failure E09; motor triac shorted or direction reversing relay contacts burned on control PCB.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor drive electronic fault E09; power board detects shorted motor triac or inverter IGBT phase breakdown.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Move Series / Multi Switch Precision Induction Hob: Internal bus communication failure E9; touch control panel loses data communication with induction power module.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: High temperature warming warning E9; fresh food compartment temperature exceeds +12°C continuously for over 2 hours.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Moisture sensing conductivity circuit error E10; sensor bars in door opening read open circuit or shorted to chassis ground.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Program selector / drum position sensor error E10; dial input signal unrecognized or top-loader drum positioning sensor missing.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Exhaust air temperature overheat E11; air temperature leaving the drum exceeds 80°C triggering thermal protection.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Washer-dryer drying heating fault E11; air heating duct fails to reach temperature or dryer thermistor open circuit.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Serial communication timeout E12; display console fails to exchange data telegrams with main chassis power board.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Washer-dryer ventilation error E12; air circulation blower motor stall or drying auxiliary controller communication loss.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Bus communication fault E13; user interface display panel loses serial handshake with main chassis power board.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Flowmeter signal missing during fill E14; pressure switch senses water rising in tub but zero flowmeter impulses arrive at PCB.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Condensate lift pump motor fault E14; pump fails to lift water from bottom collector to upper reservoir.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Wash water heating failure E14; water temperature does not rise after 20 minutes of active wash program operation.
Immersion / Air Heating Element & Klixon Thermostat
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Microcontroller memory failure E15; main control module detects an invalid EEPROM checksum or unconfigured firmware parameter.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water softener regeneration valve fault E16; salt chamber regeneration solenoid open-circuit or shorted on power board.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Heating element earth insulation leak E16; appliance trips residual current device (RCD / breaker) or detects stray current to chassis ground.
Immersion / Air Heating Element & Klixon Thermostat
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor speed signal frequency anomaly E17; tachometer pulse cadence does not match inverter drive excitation frequency.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Power supply voltage or frequency fault E18; AC mains input deviates outside allowable 190V–255V operating window.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: AC mains power supply out of limits E18; voltage fluctuates outside 185V–260V AC or frequency deviates from 50/60 Hz.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Electronic pressure sensor calibration fault E20; signal frequency received from the analog pressure transducer is out of valid bounds.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water level sensor drift E21; water column pressure rises unexpectedly while solenoid inlet valves are de-energized.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Siphoning drain detection E22; water level drops continuously during active wash fill cycle without pump activation.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Defrost heating circuit failure Ed; evaporator defrost heater fails to terminate cycle within programmed maximum runtime.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Evaporator fan rotor stall / hardware trip EF; fan motor overcurrent detected by motor driver circuitry.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Cavity overtemperature condition Er03; cavity temperature exceeds 320°C in standard baking or 520°C in pyrolytic clean mode.
Immersion / Air Heating Element & Klixon Thermostat
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Pyrolysis door lock latch failure Er05; motorized latch mechanism fails to engage door interlock within 60 seconds of cycle start.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Power relay board communication lost Er08; display interface loses serial handshake with heating element relay power module.
Immersion / Air Heating Element & Klixon Thermostat
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Low-voltage DC power supply ripple fault Er21; 5V DC or 12V DC power bus voltage drops below operating threshold.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Touch control evaluation hardware fault ER22; capacitive sensing integrated circuit detects an internal analog front-end failure.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Power board configuration data corrupted ER31; generator module variant coding table does not match cooktop model setup.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Display console temperature sensor fault Er36; on-board thermistor on user interface board reads out of range.
Haier I-Move Series / Multi Switch Precision Induction Hob: Touch board ambient NTC sensor shorted ER36; temperature sensor on user interface PCB reads short-circuit to ground.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: LIN-bus communication error Er47; internal local interconnect network link between touch interface and power module drops packets.
Immersion / Air Heating Element & Klixon Thermostat
Haier I-Move Series / Multi Switch Precision Induction Hob: LIN-Bus communication between touch controller and power inverter module missing ER47; transmission timeout error.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Move Series / Multi Switch Precision Induction Hob: Cooking coil temperature sensor disconnected F0; generator board detects open circuit on temperature feedback line.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: User interface board communication failure F0; display module cannot communicate with main power relay board.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Variable frequency inverter compressor communication fault F0; main control PCB loses PWM / UART handshake with inverter driver board.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Air intake temperature sensor fault F1; front air temperature probe disconnected or reading outside allowable bounds.
Haier I-Move Series / Multi Switch Precision Induction Hob: Cooking coil temperature sensor short circuit F1; measured probe resistance drops to near zero ohms.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Freezer evaporator fan motor malfunction F1; low-voltage brushless DC circulation fan stalled or tachometer feedback missing.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier I-Move Series / Multi Switch Precision Induction Hob: Communication loss to induction generator module F2; main controller loses sync with left or right power inverter board.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Refrigerator compartment air circulation fan fault F2; fresh food multi-airflow fan fails rotation speed verification.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Temperature sensor probe circuit open F3; sensor signal resistance is infinite, halting heating cycle.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Condenser cooling fan motor failure F3; rear machine compartment fan stalls or fails thermal heat extraction.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Condensate evacuation pump failure F4; water level switch in collection sump remains active after pump run cycle.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Temperature sensor probe short circuit F4; sensor signal resistance is near zero ohms, preventing temperature control.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Heating circuit failure F4; water does not heat up during wash phase within allotted cycle time.
Immersion / Air Heating Element & Klixon Thermostat
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Motor / compressor inverter communication timeout F5; main PCB loses data link with drive inverter module.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Cooling fan hall sensor feedback missing F5; electronics cooling fan is commanded on but speed sensor sends zero RPM.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Motorized air damper baffle malfunction F5; motorized cold air shutter fails to reach calibrated open or closed position.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Auxiliary heat-pump cooling fan fault F6; compressor compartment ventilation fan motor stalled or disconnected.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Refrigerant switching valve error F6; bistable 3-way solenoid valve fails to direct refrigerant between fridge and freezer circuits.
Haier I-Move Series / Multi Switch Precision Induction Hob: Mains supply frequency out of limits F7; AC power line frequency falls outside 47 Hz–63 Hz operating window.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor drive board communication / synchronization fault F7; inverter driver board fails to command motor rotation.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Move Series / Multi Switch Precision Induction Hob: Continuous heating safety timer shutoff F8; cooking zone automatically powers off after exceeding maximum continuous runtime limit.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Meat probe temperature limit exceeded F8; core probe signal indicates temperature above maximum safe reading.
Immersion / Air Heating Element & Klixon Thermostat
Haier I-Move Series / Multi Switch Precision Induction Hob: Induction coil current sensor calibration failure F9; current transformer sensing circuit fails zero-offset balance test at power up.
Immersion / Air Heating Element & Klixon Thermostat
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Motorized door latch switch timing error F9; latch motor runs but lock switch does not transition within expected time window.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water level frequency sensor abnormal FA; water level reading absent or outside valid frequency bounds (~20–40 kHz).
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Inverter drive communication loss FC0; main control module loses communication handshake with motor inverter module.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Display board communication timeout FC1; user interface touch panel fails to synchronize with system controller.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: EEPROM variant configuration parameter mismatch FC2; model code programming does not match installed chassis hardware.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Move Series / Multi Switch Precision Induction Hob: Mains supply undervoltage / phase missing alert U; cooktop detects open circuit on secondary phase or voltage under 170V AC.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Mains supply frequency out of limits F7; AC power line frequency falls outside 47 Hz–63 Hz operating window.
On Haier cooktops utilizing I-Move Series / Multi Switch induction power board, high-frequency coil induction, and capacitive sensor glass interface: Unstable generator or solar inverter power supply, severe grid harmonic distortion, or failed zero-crossing detection circuit on board.
Measure AC line frequency with digital multimeter (must read 50.0 Hz or 60.0 Hz ±1 Hz). If running on generator, adjust governor. Replace filter board if grid is normal. Wipe glass surface clean, disconnect power supply circuit breaker for 60 seconds, reconnect and hold Pause/Lock key for 5 seconds.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Stuck touch key / keypad matrix line shorted F7; button input is registered as permanently pressed.
On Haier ovens utilizing Chef@Home multi-zone convection system, high-precision cavity thermal probe, and I-Message electronic controller: Liquid spill on control glass, conductive residue between touch electrodes, or shorted membrane switch line.
Clean and dry control console thoroughly. If touch buttons remain unresponsive or code persists, replace touch keypad or console board. Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor drive board communication / synchronization fault F7; inverter driver board fails to command motor rotation.
On Haier washers utilizing Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Blown motor driver fuse on inverter board, damaged gate driver IC, or lost serial communication between display and drive board.
Inspect wiring harness connecting main PCB and motor drive board. Verify DC bus voltage on driver capacitors (~310V–340V DC). Replace driver board if damaged. Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Continuous heating safety timer shutoff F8; cooking zone automatically powers off after exceeding maximum continuous runtime limit.
On Haier cooktops utilizing I-Move Series / Multi Switch induction power board, high-frequency coil induction, and capacitive sensor glass interface: Safety feature: Zone operated continuously for 1 to 10 hours (depending on power setting) without touch panel interaction.
This is a normal safety feature to prevent kitchen fires. Touch the zone selection key and re-select the desired power level to resume cooking. Wipe glass surface clean, disconnect power supply circuit breaker for 60 seconds, reconnect and hold Pause/Lock key for 5 seconds.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Meat probe temperature limit exceeded F8; core probe signal indicates temperature above maximum safe reading.
On Haier ovens utilizing Chef@Home multi-zone convection system, high-precision cavity thermal probe, and I-Message electronic controller: Meat probe exposed directly to heating element radiation, shorted probe handle, or jack socket contamination.
Ensure meat probe is fully inserted into meat center and not touching bone or metal pan. Clean socket contacts with electrical contact cleaner. Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds.
Haier I-Move Series / Multi Switch Precision Induction Hob: Induction coil current sensor calibration failure F9; current transformer sensing circuit fails zero-offset balance test at power up.
On Haier cooktops utilizing I-Move Series / Multi Switch induction power board, high-frequency coil induction, and capacitive sensor glass interface: Defective current transformer on power PCB, leaky shunt resistor, or cracked ferrite core on measuring coil.
Turn off breaker for 5 minutes. If code returns upon energization, inspect power board current sensing stage or replace affected generator board. Wipe glass surface clean, disconnect power supply circuit breaker for 60 seconds, reconnect and hold Pause/Lock key for 5 seconds.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Motorized door latch switch timing error F9; latch motor runs but lock switch does not transition within expected time window.
On Haier ovens utilizing Chef@Home multi-zone convection system, high-precision cavity thermal probe, and I-Message electronic controller: Worn plastic gears in latch motor drive, oxidized limit microswitch contacts, or misaligned latch hook on oven frame.
Inspect door latch motorized assembly. Manually cycle latch mechanism to test microswitch continuity with multimeter. Replace latch unit if gears slip. Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water level frequency sensor abnormal FA; water level reading absent or outside valid frequency bounds (~20–40 kHz).
On Haier washers utilizing Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Blocked pressure switch tubing, defective electronic transducer, or broken 5V DC reference line from main PCB.
Clear pressure dome on tub and inspect hose for kinks. Measure 5V DC supply at sensor harness pins. Replace electronic pressure switch if frequency is zero. Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Inverter drive communication loss FC0; main control module loses communication handshake with motor inverter module.
On Haier washers utilizing Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Disconnected communication cable, corroded pin terminals, or power supply failure on the motor inverter board.
Inspect multi-wire serial cable between main PCB and inverter module. Re-seat connectors and check pin tension. Verify low-voltage DC rails. Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Display board communication timeout FC1; user interface touch panel fails to synchronize with system controller.
On Haier washers utilizing Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Defective wiring harness between door interface and power board, moisture inside console, or corrupted display microcontroller.
Check wiring continuity between front display board and main PCB. Dry any moisture inside display housing. Replace display PCB if communication fails. Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: EEPROM variant configuration parameter mismatch FC2; model code programming does not match installed chassis hardware.
On Haier washers utilizing Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Unprogrammed replacement control board, corrupted memory block after power surge, or incorrect model code selected.
Access service diagnostic routine and enter exact model configuration code from rating plate. If EEPROM will not store data, replace main board. Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Frozen food sensor error.. Diagnostic error code FF reported by the internal system controller.
Defective NTC Temperature Sensor Probe (Thermistor), open/short circuit in the wiring harness, or faulty connector on the ntc temperature sensor & thermistor.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Child safety lock active Loc; control panel keypad inputs are locked to prevent accidental burner/oven activation.
On Haier ovens utilizing Chef@Home multi-zone convection system, high-precision cavity thermal probe, and I-Message electronic controller: Key lock feature engaged by user holding the Keypad Lock or Clear/Off pad for 3 to 5 seconds.
Press and hold the Key Lock / Padlock icon pad continuously for 3 to 5 seconds until confirmation beep sounds and 'Loc' message disappears. Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Sabbath mode operating status Sabb; steady-state heating enabled, display tones silenced, and door switches disabled.
On Haier ovens featuring Chef@Home multi-zone convection system, high-precision cavity thermal probe, and I-Message electronic controller: Sabbath mode was intentionally or accidentally enabled through special key combination sequence.
To exit Sabbath mode: Press and hold Clock/Timer and Bake keys together for 5 seconds until display reverts to standard clock, or power cycle breaker. Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds.
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Mains supply undervoltage / phase missing alert U; cooktop detects open circuit on secondary phase or voltage under 170V AC.
On Haier cooktops utilizing I-Move Series / Multi Switch induction power board, high-frequency coil induction, and capacitive sensor glass interface: Missing copper bridging link between terminals 1 and 2 on single-phase 230V installations, or tripped split breaker.
Turn off breaker. Check junction box on hob underside. Ensure copper bridge jumper is securely tightened across terminals 1 and 2 for 230V single phase. Wipe glass surface clean, disconnect power supply circuit breaker for 60 seconds, reconnect and hold Pause/Lock key for 5 seconds.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Unbalanced load notification Unb; appliance pauses spin ramp and attempts automatic load redistribution.
On Haier washers utilizing Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Heavy single garment (jacket, bath sheet) clinging to drum wall, causing centrifugal mass imbalance.
Open door and rearrange wash items. Add one or two smaller towels to balance drum inertia during high-speed extraction. Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.