Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Critical freezer high temperature alarm AL01; freezer compartment temperature has risen above safe threshold of -9°C.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Water dispenser filter expiration / flow timeout alarm AL02; water purification filter cartridge life limit or fill slow rate detected.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water filling timeout alarm AL05; wash tank does not fill to operating level within program timeout limit.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Interface display communication error E0; temperature control panel loses serial link with master power PCB.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water fill solenoid valve circuit fault E01; power board detects open circuit across inlet solenoid coil.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Door interlock error E01; appliance refuses to commence wash cycle because the door latch contact is not verified.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water inlet fill failure E1; appliance detects no incoming water flow into sump after opening fill valve.
Haier I-Move Series / Multi Switch Precision Induction Hob: Touch sensor zone covered by object or liquid E1; continuous conductive activation detected on control glass for >10 seconds.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Refrigerator compartment temperature sensor fault E1; fresh food section thermistor circuit open or shorted.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Fill meter pulse count error E02; turbine sensor signals water fill but pulse frequency is erratic or dropping out.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Process air duct NTC sensor error E02; thermistor signal indicates circuit open, short, or temperature out of operating range.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water inlet fill timeout E02; tub does not reach the minimum operating water level within 210 seconds of valve energization.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier I-Move Series / Multi Switch Precision Induction Hob: Induction cooking zone coil overheat E2; NTC temperature sensor beneath ceramic glass detects temperature exceeding 240°C.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Freezer compartment temperature sensor malfunction E2; low-temperature NTC thermistor circuit open or short-circuited.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Door / lid lock failure E2; machine does not engage lock solenoid or detects door open during cycle start.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Maximum drying cycle time exceeded E03; machine aborts cycle after running for 210 minutes without laundry reaching target dryness.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water evacuation fault E03; machine aborts cycle with water remaining in drum after 180 seconds of drain pump operation.
Haier I-Move Series / Multi Switch Precision Induction Hob: Induction power board IGBT heatsink overtemperature E3; power transistor heatsink temperature exceeds 95°C safety shutoff.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Evaporator defrost temperature sensor fault E3; defrost termination NTC thermistor out of calibrated ohmic range.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier I-Move Series / Multi Switch Precision Induction Hob: Induction coil temperature sensor circuit fault E4; coil center NTC thermistor reads open circuit or shorted.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water fill timeout E4; water does not reach target level within 8 minutes of starting fill cycle.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water temperature sensor measurement anomaly E05; NTC probe signal resistance indicates temperature below -5°C or above 90°C.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Drum motor drive failure E06; motor hums but fails to rotate the drum, or drive motor trips on thermal overload.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Humidity sensor communication error E6; crisper drawer moisture and relative humidity module signal loss.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Drum rotation sensor speed feedback missing E07; controller does not detect drum movement during program run.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor drive tachometer fault E07; drum does not rotate or motor starts at uncontrolled high speed then immediately stops.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Wash circulation pump failure E7; motor does not rotate, tachometer feedback is absent, or run capacitor is open.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Move Series / Multi Switch Precision Induction Hob: Cooling fan failure E7; internal induction generator cooling fan motor stalled, disconnected, or zero RPM feedback.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Automatic ice maker mold temperature sensor error E7; ice tray thermistor reading out of bounds during freezing cycle.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor drive inverter module overcurrent E7; drive electronics trip on thermal overload or excessive current draw.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Flow-through heater circuit open E08; water temperature does not increase during heated wash stage.
Immersion / Air Heating Element & Klixon Thermostat
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Automatic ice maker ejection motor stall E8; ice tray harvest mechanism fails to complete home position cycle within 3 minutes.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Drum motor drive semiconductor failure E09; motor triac shorted or direction reversing relay contacts burned on control PCB.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor drive electronic fault E09; power board detects shorted motor triac or inverter IGBT phase breakdown.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Move Series / Multi Switch Precision Induction Hob: Internal bus communication failure E9; touch control panel loses data communication with induction power module.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: High temperature warming warning E9; fresh food compartment temperature exceeds +12°C continuously for over 2 hours.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Moisture sensing conductivity circuit error E10; sensor bars in door opening read open circuit or shorted to chassis ground.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Program selector / drum position sensor error E10; dial input signal unrecognized or top-loader drum positioning sensor missing.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Exhaust air temperature overheat E11; air temperature leaving the drum exceeds 80°C triggering thermal protection.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Washer-dryer drying heating fault E11; air heating duct fails to reach temperature or dryer thermistor open circuit.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Serial communication timeout E12; display console fails to exchange data telegrams with main chassis power board.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Washer-dryer ventilation error E12; air circulation blower motor stall or drying auxiliary controller communication loss.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Bus communication fault E13; user interface display panel loses serial handshake with main chassis power board.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Flowmeter signal missing during fill E14; pressure switch senses water rising in tub but zero flowmeter impulses arrive at PCB.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Condensate lift pump motor fault E14; pump fails to lift water from bottom collector to upper reservoir.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Wash water heating failure E14; water temperature does not rise after 20 minutes of active wash program operation.
Immersion / Air Heating Element & Klixon Thermostat
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Microcontroller memory failure E15; main control module detects an invalid EEPROM checksum or unconfigured firmware parameter.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water softener regeneration valve fault E16; salt chamber regeneration solenoid open-circuit or shorted on power board.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Heating element earth insulation leak E16; appliance trips residual current device (RCD / breaker) or detects stray current to chassis ground.
Immersion / Air Heating Element & Klixon Thermostat
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor speed signal frequency anomaly E17; tachometer pulse cadence does not match inverter drive excitation frequency.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Power supply voltage or frequency fault E18; AC mains input deviates outside allowable 190V–255V operating window.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: AC mains power supply out of limits E18; voltage fluctuates outside 185V–260V AC or frequency deviates from 50/60 Hz.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Electronic pressure sensor calibration fault E20; signal frequency received from the analog pressure transducer is out of valid bounds.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water level sensor drift E21; water column pressure rises unexpectedly while solenoid inlet valves are de-energized.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Siphoning drain detection E22; water level drops continuously during active wash fill cycle without pump activation.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Defrost heating circuit failure Ed; evaporator defrost heater fails to terminate cycle within programmed maximum runtime.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Evaporator fan rotor stall / hardware trip EF; fan motor overcurrent detected by motor driver circuitry.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Cavity overtemperature condition Er03; cavity temperature exceeds 320°C in standard baking or 520°C in pyrolytic clean mode.
Immersion / Air Heating Element & Klixon Thermostat
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Pyrolysis door lock latch failure Er05; motorized latch mechanism fails to engage door interlock within 60 seconds of cycle start.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Power relay board communication lost Er08; display interface loses serial handshake with heating element relay power module.
Immersion / Air Heating Element & Klixon Thermostat
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Low-voltage DC power supply ripple fault Er21; 5V DC or 12V DC power bus voltage drops below operating threshold.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Touch control evaluation hardware fault ER22; capacitive sensing integrated circuit detects an internal analog front-end failure.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Power board configuration data corrupted ER31; generator module variant coding table does not match cooktop model setup.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Display console temperature sensor fault Er36; on-board thermistor on user interface board reads out of range.
Haier I-Move Series / Multi Switch Precision Induction Hob: Touch board ambient NTC sensor shorted ER36; temperature sensor on user interface PCB reads short-circuit to ground.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: LIN-bus communication error Er47; internal local interconnect network link between touch interface and power module drops packets.
Immersion / Air Heating Element & Klixon Thermostat
Haier I-Move Series / Multi Switch Precision Induction Hob: LIN-Bus communication between touch controller and power inverter module missing ER47; transmission timeout error.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Move Series / Multi Switch Precision Induction Hob: Cooking coil temperature sensor disconnected F0; generator board detects open circuit on temperature feedback line.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: User interface board communication failure F0; display module cannot communicate with main power relay board.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Variable frequency inverter compressor communication fault F0; main control PCB loses PWM / UART handshake with inverter driver board.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Air intake temperature sensor fault F1; front air temperature probe disconnected or reading outside allowable bounds.
Haier I-Move Series / Multi Switch Precision Induction Hob: Cooking coil temperature sensor short circuit F1; measured probe resistance drops to near zero ohms.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Freezer evaporator fan motor malfunction F1; low-voltage brushless DC circulation fan stalled or tachometer feedback missing.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier I-Move Series / Multi Switch Precision Induction Hob: Communication loss to induction generator module F2; main controller loses sync with left or right power inverter board.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Refrigerator compartment air circulation fan fault F2; fresh food multi-airflow fan fails rotation speed verification.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Temperature sensor probe circuit open F3; sensor signal resistance is infinite, halting heating cycle.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Condenser cooling fan motor failure F3; rear machine compartment fan stalls or fails thermal heat extraction.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Condensate evacuation pump failure F4; water level switch in collection sump remains active after pump run cycle.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Temperature sensor probe short circuit F4; sensor signal resistance is near zero ohms, preventing temperature control.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Heating circuit failure F4; water does not heat up during wash phase within allotted cycle time.
Immersion / Air Heating Element & Klixon Thermostat
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Motor / compressor inverter communication timeout F5; main PCB loses data link with drive inverter module.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Cooling fan hall sensor feedback missing F5; electronics cooling fan is commanded on but speed sensor sends zero RPM.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Motorized air damper baffle malfunction F5; motorized cold air shutter fails to reach calibrated open or closed position.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Auxiliary heat-pump cooling fan fault F6; compressor compartment ventilation fan motor stalled or disconnected.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Refrigerant switching valve error F6; bistable 3-way solenoid valve fails to direct refrigerant between fridge and freezer circuits.
Haier I-Move Series / Multi Switch Precision Induction Hob: Mains supply frequency out of limits F7; AC power line frequency falls outside 47 Hz–63 Hz operating window.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor drive board communication / synchronization fault F7; inverter driver board fails to command motor rotation.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Move Series / Multi Switch Precision Induction Hob: Continuous heating safety timer shutoff F8; cooking zone automatically powers off after exceeding maximum continuous runtime limit.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Meat probe temperature limit exceeded F8; core probe signal indicates temperature above maximum safe reading.
Immersion / Air Heating Element & Klixon Thermostat
Haier I-Move Series / Multi Switch Precision Induction Hob: Induction coil current sensor calibration failure F9; current transformer sensing circuit fails zero-offset balance test at power up.
Immersion / Air Heating Element & Klixon Thermostat
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Motorized door latch switch timing error F9; latch motor runs but lock switch does not transition within expected time window.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water level frequency sensor abnormal FA; water level reading absent or outside valid frequency bounds (~20–40 kHz).
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Inverter drive communication loss FC0; main control module loses communication handshake with motor inverter module.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Display board communication timeout FC1; user interface touch panel fails to synchronize with system controller.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: EEPROM variant configuration parameter mismatch FC2; model code programming does not match installed chassis hardware.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Move Series / Multi Switch Precision Induction Hob: Mains supply undervoltage / phase missing alert U; cooktop detects open circuit on secondary phase or voltage under 170V AC.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Critical freezer high temperature alarm AL01; freezer compartment temperature has risen above safe threshold of -9°C.
On Haier refrigeration units featuring Fresher Shield Total No-Frost inverter cooling, multi-airflow tower, and ABT antibacterial preservation system: Prolonged domestic power outage, freezer door left open, heavy loading of unfrozen food, or refrigerant leak.
Mute acoustic alarm with Alarm Reset button. Activate Super Freeze mode for 12 hours. Verify compressor runs and evaporator chills down to -18°C. Reset: Press and hold Fridge Temp and Freezer Temp keys together for 6 seconds until long beep confirms electronic board reset.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Water dispenser filter expiration / flow timeout alarm AL02; water purification filter cartridge life limit or fill slow rate detected.
On Haier refrigeration units featuring Fresher Shield Total No-Frost inverter cooling, multi-airflow tower, and ABT antibacterial preservation system: 6-month cartridge timer elapsed, clogged carbon block filter, or low household water line pressure (<1.5 bar).
Replace internal water filter cartridge. Flush 5 liters through dispenser to purge air. Press and hold Water Filter Reset button for 3 seconds. Reset: Press and hold Fridge Temp and Freezer Temp keys together for 6 seconds until long beep confirms electronic board reset.
On Haier dishwashers powered by I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Heavy grease clogs in drain hose, sink siphon nipple blocked, or drain pump motor winding weakened (~160–220 Ω).
Disconnect drain hose from under-sink siphon and verify clear bore. Flush drain hose with warm water. Measure pump motor resistance (~160–220 Ω). Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water filling timeout alarm AL05; wash tank does not fill to operating level within program timeout limit.
On Haier dishwashers utilizing I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Scaled water supply tap, blocked metal strainer mesh in inlet hose connector, or defective inlet valve (~3.5–4.5 kΩ).
Check faucet flow rate with bucket test. Remove supply hose and rinse out particulate debris from inlet filter. Measure valve solenoid (~3.5–4.5 kΩ). Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Tub clean safety drain prompt CLr; automated maintenance rinse cycle or reminder to clean drum interior.
On Haier washers utilizing Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Machine cycle counter has reached threshold (typically 50 wash cycles) without a high-temperature Tub Clean cycle.
Empty the drum completely, add machine descaler or oxygen bleach directly into drum, select Tub Clean program, and allow complete 90°C cycle to finish. Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Touch control module initialization error E0; touch interface microcontroller fails internal RAM diagnostic self-test.
On Haier cooktops utilizing I-Move Series / Multi Switch induction power board, high-frequency coil induction, and capacitive sensor glass interface: Mains supply transient voltage fluctuation during power-up, corrupted microprocessor registers, or dry electrolytic filter cap.
Power off at mains consumer unit for 60 seconds. Restore power and observe initialization. If code reoccurs instantly, replace touch control PCB. Wipe glass surface clean, disconnect power supply circuit breaker for 60 seconds, reconnect and hold Pause/Lock key for 5 seconds.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Interface display communication error E0; temperature control panel loses serial link with master power PCB.
On Haier refrigeration units featuring Fresher Shield Total No-Frost inverter cooling, multi-airflow tower, and ABT antibacterial preservation system: Damaged door hinge wire harness, oxidized ribbon connector, or missing 5V DC low-voltage rail.
Inspect top door hinge wiring harness for fatigue breaks. Check 5V DC and 12V DC power pins at display connector CN1. Reset procedure: Press and hold Fridge Temp and Freezer Temp keys together for 6 seconds until long beep confirms electronic board reset.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water fill solenoid valve circuit fault E01; power board detects open circuit across inlet solenoid coil.
On Haier dishwashers powered by I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Burned inlet valve coil (~3.8 kΩ nominal), corroded connector spade terminals, or broken wire in door hinge harness.
Measure inlet valve coil resistance (~3.5–4.5 kΩ). Inspect wiring harness continuity from control board. Replace valve assembly if coil is infinite ohms. Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Airflow restriction warning E01; door lint filter clogged or lower heat exchanger condenser obstructed with lint.
On Haier tumble dryers utilizing I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Dense lint coating on fine mesh screen, blocked air passage in lower plinth, or high differential temperature across air duct.
Remove door lint filter and wash under warm tap water; dry before refitting. Open bottom plinth and vacuum condenser aluminum fins. Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Door interlock error E01; appliance refuses to commence wash cycle because the door latch contact is not verified.
On Haier washing machines utilizing Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Defective door latch microswitch, laundry pinched in the rubber bellow, or open PTC solenoid coil (~900–1200 Ω).
Verify door latch alignment. Inspect wiring harness between lock and main module. Measure lock coil resistance (~900–1200 Ω across terminals 1-3). Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water inlet fill failure E1; appliance detects no incoming water flow into sump after opening fill valve.
On Haier dishwashers utilizing I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Closed water supply valve, kinked inlet hose, blocked AquaStop mesh filter, or open valve coil (~3.5–4.5 kΩ).
Check water supply tap pressure. Unscrew supply hose and clean AquaStop inlet filter screen. Measure solenoid valve coil (~3.5–4.5 kΩ). Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Touch sensor zone covered by object or liquid E1; continuous conductive activation detected on control glass for >10 seconds.
On Haier cooktops featuring I-Move Series / Multi Switch induction power board, high-frequency coil induction, and capacitive sensor glass interface: Boiled-over cooking liquid, conductive grease, wet cleaning rag, or metal pot lid resting directly over touch sensors.
Remove all cookware from control area. Wipe glass dry using a dry cotton towel. Clean any dried salt or starch residue. Wipe glass surface clean, disconnect power supply circuit breaker for 60 seconds, reconnect and hold Pause/Lock key for 5 seconds.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Refrigerator compartment temperature sensor fault E1; fresh food section thermistor circuit open or shorted.
On Haier refrigeration units featuring Fresher Shield Total No-Frost inverter cooling, multi-airflow tower, and ABT antibacterial preservation system: Drifted NTC sensing bead, moisture ingress behind cabinet liner, or degraded wiring connector.
Measure NTC resistance at main PCB connector: standard value is ~5 kΩ at 25°C, rising to ~16.3 kΩ at 0°C. Replace sensor if out of tolerance. Reset: Press and hold Fridge Temp and Freezer Temp keys together for 6 seconds until long beep confirms electronic board reset.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water drainage failure E1; machine unable to drain water from wash tub within 4 minutes.
On Haier washers utilizing Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Blocked coin trap filter, kinked drain hose, pump impeller jammed by foreign object, or pump motor coil open (~160–220 Ω).
Clean drain pump filter at lower front. Verify free impeller rotation. Check pump resistance (~160–220 Ω across terminals). Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Fill meter pulse count error E02; turbine sensor signals water fill but pulse frequency is erratic or dropping out.
On Haier dishwashers featuring I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Magnet pin loose in flowmeter impeller, limescale accumulation inside water jacket labyrinth, or oxidized plug contacts.
Inspect left-side plastic air break for scale deposits. Clean electrical contacts on reed switch PCB with contact spray. Replace air break if impeller sticks. Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Process air duct NTC sensor error E02; thermistor signal indicates circuit open, short, or temperature out of operating range.
On Haier tumble dryers powered by I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Defective front airflow NTC thermistor bead (~20.0 kΩ at 25°C), disconnected spade terminals, or wire chafing.
Locate NTC probe at front blower duct. Disconnect wire terminals and measure resistance (~20.0 kΩ at 25°C, ~4.5 kΩ at 60°C). Replace if open. Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water inlet fill timeout E02; tub does not reach the minimum operating water level within 210 seconds of valve energization.
On Haier washing machines with Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Closed tap, kinked fill hose, clogged inlet valve mesh filter, or open solenoid coil (~3.5–4.5 kΩ).
Confirm mains water flow rate (>10 L/min). Clean the inlet filter screen. Check dual solenoid valve coil resistances (~3.5–4.5 kΩ). Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water fill timeout E2; flowmeter turbine pulse rate below threshold (<10 impulses per 100ml) during wash chamber filling.
On Haier dishwashers featuring I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Low line water pressure, scaled impeller in water jacket flowmeter, or defective reed switch sensor board.
Verify household water pressure (>1.5 bar). Inspect side air-break matrix for scale build-up. Test flowmeter reed switch continuity during active fill. Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
Haier I-Move Series / Multi Switch Precision Induction Hob: Induction cooking zone coil overheat E2; NTC temperature sensor beneath ceramic glass detects temperature exceeding 240°C.
On Haier cooktops utilizing I-Move Series / Multi Switch induction power board, high-frequency coil induction, and capacitive sensor glass interface: Empty pot heated at booster setting (dry boil), thin warped pan base creating localized hot spot, or fan airflow blocked.
Switch off the cooking zone and remove cookware. Allow zone to cool down for 15 minutes. Check coil NTC thermistor resistance with a multimeter (~100 kΩ at 25°C). Verify bottom cabinetry intake air slots are not obstructed. Wipe glass surface clean, disconnect power supply circuit breaker for 60 seconds, reconnect and hold Pause/Lock key for 5 seconds.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Freezer compartment temperature sensor malfunction E2; low-temperature NTC thermistor circuit open or short-circuited.
On Haier refrigeration units featuring Fresher Shield Total No-Frost inverter cooling, multi-airflow tower, and ABT antibacterial preservation system: Thermal fatigue under freezing cycles, moisture degradation in sensing tip, or severed freezer wire line.
Test freezer NTC resistance: nominal is ~5 kΩ at 25°C and ~32.5 kΩ at -18°C. Replace sensor assembly if open (>100 kΩ) or shorted (<500 Ω). Reset: Press and hold Fridge Temp and Freezer Temp keys together for 6 seconds until long beep confirms electronic board reset.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Door / lid lock failure E2; machine does not engage lock solenoid or detects door open during cycle start.
On Haier washers featuring Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Door catch out of alignment, defective door lock switch mechanism, or damaged wiring harness to main controller.
Inspect door strike hook. Verify door switch continuity with door closed. Replace door lock assembly if solenoid fails to latch. Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Drain pump evacuation timeout E03; water remains detected in sump chamber after drain cycle timer elapses.
On Haier dishwashers powered by I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Toothpick or small bone jammed in pump impeller chamber, clogged corrugated drain hose, or worn pump motor (~160–220 Ω).
Remove sump filter cover and clear debris around drain impeller. Ensure hose is unobstructed to drain standpipe. Measure pump coil resistance (~160–220 Ω). Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Maximum drying cycle time exceeded E03; machine aborts cycle after running for 210 minutes without laundry reaching target dryness.
On Haier tumble dryers utilizing I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Severely fouled condenser unit, weak heat-pump refrigerant pressure, or wet clothes spun at too low wash RPM (<800 RPM).
Always spin clothes at minimum 1000 RPM in washing machine. Thoroughly clean heat exchanger fins with soft brush. Verify compressor operating heat. Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water evacuation fault E03; machine aborts cycle with water remaining in drum after 180 seconds of drain pump operation.
On Haier washing machines featuring Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Blocked coin trap filter, foreign object jamming synchronous impeller, kinked drain hose, or open pump motor (~160–220 Ω).
Unscrew front coin filter and remove obstructions. Inspect impeller rotation. Measure drain pump winding resistance (~160–220 Ω). Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Drain evacuation timeout E3; water remains in sump after 240 seconds of drain pump operation.
On Haier dishwashers powered by I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Blocked microfilter, foreign body (glass shard, olive pit) jamming drain impeller, kinked hose, or open pump motor (~160–220 Ω).
Remove sump filters and clean thoroughly. Check drain pump impeller for free rotation. Measure drain pump winding resistance (~160–220 Ω). Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
Haier I-Move Series / Multi Switch Precision Induction Hob: Induction power board IGBT heatsink overtemperature E3; power transistor heatsink temperature exceeds 95°C safety shutoff.
On Haier cooktops featuring I-Move Series / Multi Switch induction power board, high-frequency coil induction, and capacitive sensor glass interface: Inoperative cooling fan, cutlery drawer or oven installed below hob blocking intake air, or dried thermal paste on heatsink.
Ensure minimum 20 mm air intake gap below hob and 5 mm frontal air exhaust gap. Test cooling fan spins freely and fan motor connector is plugged tight. Wipe glass surface clean, disconnect power supply circuit breaker for 60 seconds, reconnect and hold Pause/Lock key for 5 seconds.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Evaporator defrost temperature sensor fault E3; defrost termination NTC thermistor out of calibrated ohmic range.
On Haier refrigeration units featuring Fresher Shield Total No-Frost inverter cooling, multi-airflow tower, and ABT antibacterial preservation system: Corrosion from defrost meltwater, loose mounting clip on accumulator tube, or internal resistor rupture.
Unclip defrost sensor from evaporator tubing. Check resistance (~5 kΩ at 25°C, ~16.3 kΩ at 0°C). Re-clip securely with thermal compound. Reset: Press and hold Fridge Temp and Freezer Temp keys together for 6 seconds until long beep confirms electronic board reset.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Spin cycle unbalance alert E3; drum cannot distribute wet laundry load evenly to reach high spin speeds safely.
On Haier washers utilizing Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Single heavy towel or bath rug, unevenly distributed bedding, or appliance chassis unlevel on floor.
Pause cycle, open door and manually untangle and redistribute garments. Check spirit level on top cover and adjust leveling feet. Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Bottom tray anti-flood switch activated E04; water detected in base pan, triggering continuous drain and lock-out.
On Haier dishwashers utilizing I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Sump O-ring seal leak, perforated tub stainless steel seam, dripping wash pump shaft seal, or leaking water jacket hose.
Isolate electrical supply. Remove side panels and dry bottom pan. Run test cycle while inspecting sump joint, pump mechanical seal, and hose clamps with a torch. Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
On Haier tumble dryers powered by I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Welded relay contacts on control board, open safety thermal cutout fuse, or burned heating coil (~20–40 Ω).
Disconnect heater leads and measure element resistance (~20–40 Ω). Test safety thermostat continuity. Inspect board relay for welded contacts. Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off.