Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Critical freezer high temperature alarm AL01; freezer compartment temperature has risen above safe threshold of -9°C.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Water dispenser filter expiration / flow timeout alarm AL02; water purification filter cartridge life limit or fill slow rate detected.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water filling timeout alarm AL05; wash tank does not fill to operating level within program timeout limit.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Interface display communication error E0; temperature control panel loses serial link with master power PCB.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water fill solenoid valve circuit fault E01; power board detects open circuit across inlet solenoid coil.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Door interlock error E01; appliance refuses to commence wash cycle because the door latch contact is not verified.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water inlet fill failure E1; appliance detects no incoming water flow into sump after opening fill valve.
Haier I-Move Series / Multi Switch Precision Induction Hob: Touch sensor zone covered by object or liquid E1; continuous conductive activation detected on control glass for >10 seconds.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Refrigerator compartment temperature sensor fault E1; fresh food section thermistor circuit open or shorted.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Fill meter pulse count error E02; turbine sensor signals water fill but pulse frequency is erratic or dropping out.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Process air duct NTC sensor error E02; thermistor signal indicates circuit open, short, or temperature out of operating range.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water inlet fill timeout E02; tub does not reach the minimum operating water level within 210 seconds of valve energization.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier I-Move Series / Multi Switch Precision Induction Hob: Induction cooking zone coil overheat E2; NTC temperature sensor beneath ceramic glass detects temperature exceeding 240°C.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Freezer compartment temperature sensor malfunction E2; low-temperature NTC thermistor circuit open or short-circuited.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Door / lid lock failure E2; machine does not engage lock solenoid or detects door open during cycle start.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Maximum drying cycle time exceeded E03; machine aborts cycle after running for 210 minutes without laundry reaching target dryness.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water evacuation fault E03; machine aborts cycle with water remaining in drum after 180 seconds of drain pump operation.
Haier I-Move Series / Multi Switch Precision Induction Hob: Induction power board IGBT heatsink overtemperature E3; power transistor heatsink temperature exceeds 95°C safety shutoff.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Evaporator defrost temperature sensor fault E3; defrost termination NTC thermistor out of calibrated ohmic range.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier I-Move Series / Multi Switch Precision Induction Hob: Induction coil temperature sensor circuit fault E4; coil center NTC thermistor reads open circuit or shorted.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water fill timeout E4; water does not reach target level within 8 minutes of starting fill cycle.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water temperature sensor measurement anomaly E05; NTC probe signal resistance indicates temperature below -5°C or above 90°C.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Drum motor drive failure E06; motor hums but fails to rotate the drum, or drive motor trips on thermal overload.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Humidity sensor communication error E6; crisper drawer moisture and relative humidity module signal loss.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Drum rotation sensor speed feedback missing E07; controller does not detect drum movement during program run.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor drive tachometer fault E07; drum does not rotate or motor starts at uncontrolled high speed then immediately stops.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Wash circulation pump failure E7; motor does not rotate, tachometer feedback is absent, or run capacitor is open.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Move Series / Multi Switch Precision Induction Hob: Cooling fan failure E7; internal induction generator cooling fan motor stalled, disconnected, or zero RPM feedback.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Automatic ice maker mold temperature sensor error E7; ice tray thermistor reading out of bounds during freezing cycle.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor drive inverter module overcurrent E7; drive electronics trip on thermal overload or excessive current draw.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Flow-through heater circuit open E08; water temperature does not increase during heated wash stage.
Immersion / Air Heating Element & Klixon Thermostat
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Automatic ice maker ejection motor stall E8; ice tray harvest mechanism fails to complete home position cycle within 3 minutes.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Drum motor drive semiconductor failure E09; motor triac shorted or direction reversing relay contacts burned on control PCB.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor drive electronic fault E09; power board detects shorted motor triac or inverter IGBT phase breakdown.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Move Series / Multi Switch Precision Induction Hob: Internal bus communication failure E9; touch control panel loses data communication with induction power module.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: High temperature warming warning E9; fresh food compartment temperature exceeds +12°C continuously for over 2 hours.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Moisture sensing conductivity circuit error E10; sensor bars in door opening read open circuit or shorted to chassis ground.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Program selector / drum position sensor error E10; dial input signal unrecognized or top-loader drum positioning sensor missing.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Exhaust air temperature overheat E11; air temperature leaving the drum exceeds 80°C triggering thermal protection.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Washer-dryer drying heating fault E11; air heating duct fails to reach temperature or dryer thermistor open circuit.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Serial communication timeout E12; display console fails to exchange data telegrams with main chassis power board.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Washer-dryer ventilation error E12; air circulation blower motor stall or drying auxiliary controller communication loss.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Bus communication fault E13; user interface display panel loses serial handshake with main chassis power board.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Flowmeter signal missing during fill E14; pressure switch senses water rising in tub but zero flowmeter impulses arrive at PCB.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Condensate lift pump motor fault E14; pump fails to lift water from bottom collector to upper reservoir.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Wash water heating failure E14; water temperature does not rise after 20 minutes of active wash program operation.
Immersion / Air Heating Element & Klixon Thermostat
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Microcontroller memory failure E15; main control module detects an invalid EEPROM checksum or unconfigured firmware parameter.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water softener regeneration valve fault E16; salt chamber regeneration solenoid open-circuit or shorted on power board.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Heating element earth insulation leak E16; appliance trips residual current device (RCD / breaker) or detects stray current to chassis ground.
Immersion / Air Heating Element & Klixon Thermostat
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor speed signal frequency anomaly E17; tachometer pulse cadence does not match inverter drive excitation frequency.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Power supply voltage or frequency fault E18; AC mains input deviates outside allowable 190V–255V operating window.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: AC mains power supply out of limits E18; voltage fluctuates outside 185V–260V AC or frequency deviates from 50/60 Hz.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Electronic pressure sensor calibration fault E20; signal frequency received from the analog pressure transducer is out of valid bounds.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water level sensor drift E21; water column pressure rises unexpectedly while solenoid inlet valves are de-energized.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Siphoning drain detection E22; water level drops continuously during active wash fill cycle without pump activation.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Defrost heating circuit failure Ed; evaporator defrost heater fails to terminate cycle within programmed maximum runtime.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Evaporator fan rotor stall / hardware trip EF; fan motor overcurrent detected by motor driver circuitry.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Cavity overtemperature condition Er03; cavity temperature exceeds 320°C in standard baking or 520°C in pyrolytic clean mode.
Immersion / Air Heating Element & Klixon Thermostat
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Pyrolysis door lock latch failure Er05; motorized latch mechanism fails to engage door interlock within 60 seconds of cycle start.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Power relay board communication lost Er08; display interface loses serial handshake with heating element relay power module.
Immersion / Air Heating Element & Klixon Thermostat
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Low-voltage DC power supply ripple fault Er21; 5V DC or 12V DC power bus voltage drops below operating threshold.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Touch control evaluation hardware fault ER22; capacitive sensing integrated circuit detects an internal analog front-end failure.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Power board configuration data corrupted ER31; generator module variant coding table does not match cooktop model setup.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Display console temperature sensor fault Er36; on-board thermistor on user interface board reads out of range.
Haier I-Move Series / Multi Switch Precision Induction Hob: Touch board ambient NTC sensor shorted ER36; temperature sensor on user interface PCB reads short-circuit to ground.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: LIN-bus communication error Er47; internal local interconnect network link between touch interface and power module drops packets.
Immersion / Air Heating Element & Klixon Thermostat
Haier I-Move Series / Multi Switch Precision Induction Hob: LIN-Bus communication between touch controller and power inverter module missing ER47; transmission timeout error.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Move Series / Multi Switch Precision Induction Hob: Cooking coil temperature sensor disconnected F0; generator board detects open circuit on temperature feedback line.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: User interface board communication failure F0; display module cannot communicate with main power relay board.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Variable frequency inverter compressor communication fault F0; main control PCB loses PWM / UART handshake with inverter driver board.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Air intake temperature sensor fault F1; front air temperature probe disconnected or reading outside allowable bounds.
Haier I-Move Series / Multi Switch Precision Induction Hob: Cooking coil temperature sensor short circuit F1; measured probe resistance drops to near zero ohms.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Freezer evaporator fan motor malfunction F1; low-voltage brushless DC circulation fan stalled or tachometer feedback missing.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier I-Move Series / Multi Switch Precision Induction Hob: Communication loss to induction generator module F2; main controller loses sync with left or right power inverter board.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Refrigerator compartment air circulation fan fault F2; fresh food multi-airflow fan fails rotation speed verification.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Temperature sensor probe circuit open F3; sensor signal resistance is infinite, halting heating cycle.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Condenser cooling fan motor failure F3; rear machine compartment fan stalls or fails thermal heat extraction.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Condensate evacuation pump failure F4; water level switch in collection sump remains active after pump run cycle.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Temperature sensor probe short circuit F4; sensor signal resistance is near zero ohms, preventing temperature control.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Heating circuit failure F4; water does not heat up during wash phase within allotted cycle time.
Immersion / Air Heating Element & Klixon Thermostat
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Motor / compressor inverter communication timeout F5; main PCB loses data link with drive inverter module.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Cooling fan hall sensor feedback missing F5; electronics cooling fan is commanded on but speed sensor sends zero RPM.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Motorized air damper baffle malfunction F5; motorized cold air shutter fails to reach calibrated open or closed position.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Auxiliary heat-pump cooling fan fault F6; compressor compartment ventilation fan motor stalled or disconnected.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Refrigerant switching valve error F6; bistable 3-way solenoid valve fails to direct refrigerant between fridge and freezer circuits.
Haier I-Move Series / Multi Switch Precision Induction Hob: Mains supply frequency out of limits F7; AC power line frequency falls outside 47 Hz–63 Hz operating window.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor drive board communication / synchronization fault F7; inverter driver board fails to command motor rotation.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Move Series / Multi Switch Precision Induction Hob: Continuous heating safety timer shutoff F8; cooking zone automatically powers off after exceeding maximum continuous runtime limit.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Meat probe temperature limit exceeded F8; core probe signal indicates temperature above maximum safe reading.
Immersion / Air Heating Element & Klixon Thermostat
Haier I-Move Series / Multi Switch Precision Induction Hob: Induction coil current sensor calibration failure F9; current transformer sensing circuit fails zero-offset balance test at power up.
Immersion / Air Heating Element & Klixon Thermostat
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Motorized door latch switch timing error F9; latch motor runs but lock switch does not transition within expected time window.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water level frequency sensor abnormal FA; water level reading absent or outside valid frequency bounds (~20–40 kHz).
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Inverter drive communication loss FC0; main control module loses communication handshake with motor inverter module.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Display board communication timeout FC1; user interface touch panel fails to synchronize with system controller.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: EEPROM variant configuration parameter mismatch FC2; model code programming does not match installed chassis hardware.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Move Series / Multi Switch Precision Induction Hob: Mains supply undervoltage / phase missing alert U; cooktop detects open circuit on secondary phase or voltage under 170V AC.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Electronic pressure sensor calibration fault E20; signal frequency received from the analog pressure transducer is out of valid bounds.
On Haier washing machines powered by Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Blocked pressure tube, punctured silicone diaphragm, or defective oscillator in electronic pressure switch (~25.6 kHz empty).
Inspect rubber pressure hose for pinholes or splits. Blow through tube towards tub to clear compression dome. Measure sensor output frequency (~25.6 kHz empty). Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
On Haier tumble dryers utilizing I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Wet conductive fluff bridging sensor strips to chassis, moisture inside front fascia harness, or operational amplifier IC drift.
Thoroughly vacuum lint from sensor bar mounting insulator. Check resistance between sensor strips and chassis (must be infinite >20 MΩ when dry). Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water level sensor drift E21; water column pressure rises unexpectedly while solenoid inlet valves are de-energized.
On Haier washing machines featuring Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Mechanically weeping solenoid valve diaphragm allowing slow drip, or moisture condensation inside the pressure switch transducer.
Turn off water tap overnight to verify if tub collects water (confirms weeping valve; replace valve). Inspect pressure switch tubing for water droplets. Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Siphoning drain detection E22; water level drops continuously during active wash fill cycle without pump activation.
On Haier washing machines featuring Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Drain hose installed too low (<65 cm height), drain hose pushed too far into standpipe creating airtight siphon seal.
Ensure top of drain hose bend is suspended between 65 cm and 100 cm above floor level. Use anti-siphon curved elbow and provide air gap in standpipe. Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Condenser tube temperature sensor error EA; discharge line thermistor reading indicates abnormal thermal overload.
On Haier refrigeration units featuring Fresher Shield Total No-Frost inverter cooling, multi-airflow tower, and ABT antibacterial preservation system: Blocked condenser air intake, failed condenser cooling fan, or drifted discharge thermistor resistance.
Clean rear air grilles and condenser mesh. Check condenser NTC sensor resistance (~5 kΩ at 25°C). Ensure minimum 5 cm clearance from rear wall. Reset: Press and hold Fridge Temp and Freezer Temp keys together for 6 seconds until long beep confirms electronic board reset.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Detergent dispenser actuator fault Ed; tablet door flap fails to trip open during primary wash cycle.
On Haier dishwashers powered by I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Open dispenser wax motor or solenoid actuator coil (~1.5–3.0 kΩ), mechanical latch jam, or broken door wiring.
Remove inner door panel. Measure dispenser actuator coil resistance (~1.5–3.0 kΩ). Check spring-loaded flap latch for smooth movement. Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Defrost heating circuit failure Ed; evaporator defrost heater fails to terminate cycle within programmed maximum runtime.
On Haier refrigeration units featuring Fresher Shield Total No-Frost inverter cooling, multi-airflow tower, and ABT antibacterial preservation system: Blown thermal cutoff fuse (72°C/77°C), burned calrod or glass defrost heating element, or stuck defrost relay.
Check defrost heating element resistance (typically 180-280 Ω). Verify continuity across thermal fuse (0 Ω; replace if open). Check 230V AC output from main PCB defrost relay. Reset: Press and hold Fridge Temp and Freezer Temp keys together for 6 seconds until long beep confirms electronic board reset.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Flowmeter pulse overflow anomaly EF; impulse count exceeds maximum safety tank volume during filling phase.
On Haier dishwashers featuring I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Siphoning water leaking continuously out of drain hose during fill, or defective pressure switch failing to register water depth.
Check drain hose standpipe height (must be between 65 cm and 100 cm). Clear pressure switch dome in sump. Check pressure transducer contacts. Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Evaporator fan rotor stall / hardware trip EF; fan motor overcurrent detected by motor driver circuitry.
On Haier refrigeration units featuring Fresher Shield Total No-Frost inverter cooling, multi-airflow tower, and ABT antibacterial preservation system: Heavy Frost buildup surrounding fan blades, ice intrusion into motor hub, or shorted motor phase winding.
Perform complete 24h manual defrost to clear ice jacket. Verify fan spins freely by hand. Check winding resistance; replace fan if winding shorted. Reset: Press and hold Fridge Temp and Freezer Temp keys together for 6 seconds until long beep confirms electronic board reset.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Heating circuit safety thermal overheat Eh; water temperature sensor detects temperature exceeding 85°C.
On Haier dishwashers utilizing I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Welded heating relay contacts on main PCB keeping heater powered continually, or defective NTC sensor.
Disconnect mains immediately. Measure heater relay output voltage with machine in standby (must be 0V AC; if 230V AC present, relay is welded). Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Low incoming water pressure detected EL; flowmeter pulse cadence indicates line pressure under 0.5 bar.
On Haier dishwashers featuring I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Partially open supply stopcock, clogged sediment pre-filter in building plumbing, or shared simultaneous water usage.
Open inlet stopcock fully. Disconnect fill hose and run water into bucket to measure flow rate (minimum 8 liters per minute required). Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Electronic controller EEPROM checksum error Er; microcontroller fails internal data validation checksum on power-up.
On Haier refrigeration units featuring Fresher Shield Total No-Frost inverter cooling, multi-airflow tower, and ABT antibacterial preservation system: Mains voltage surge or lightning strike spike, electrical storm noise, or degraded non-volatile memory cell.
Disconnect mains plug for 10 minutes to allow DC capacitors to discharge completely. If fault persists on reboot, replace programmed main board. Reset: Press and hold Fridge Temp and Freezer Temp keys together for 6 seconds until long beep confirms electronic board reset.
Isolate power at breaker. Disconnect sensor plug at rear. Measure probe resistance (~538 Ω for PT500 or ~1078 Ω for PT1000 at 20°C). Replace if infinite. Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Cavity temperature sensor short circuit Er02; measured resistance across probe terminals drops below 100 Ω threshold.
On Haier ovens powered by Chef@Home multi-zone convection system, high-precision cavity thermal probe, and I-Message electronic controller: Pinching of probe lead wires by rear metal backplate screws, crushed fiberglass sleeving, or internal short in sensing bulb.
Inspect wiring harness from probe to PCB for pinched insulation. Verify probe resistance disconnected from PCB (nominal ~538 Ω / ~1078 Ω at 20°C). Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Cavity overtemperature condition Er03; cavity temperature exceeds 320°C in standard baking or 520°C in pyrolytic clean mode.
On Haier ovens featuring Chef@Home multi-zone convection system, high-precision cavity thermal probe, and I-Message electronic controller: Welded heating element relay contacts on power board keeping elements energized continuously, or defective probe.
Disconnect power breaker immediately. Allow oven to cool down completely. Test heating element relay contacts on power PCB for short circuit. Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds.
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Permanent touch key activation alarm ER03; liquid spill or cookware resting continuously on sensor controls.
On Haier cooktops utilizing I-Move Series / Multi Switch induction power board, high-frequency coil induction, and capacitive sensor glass interface: Heavy liquid overflow across touch buttons, conductive sauce splatter, or pan overhang onto glass touch zone.
Remove all pots and utensils from glass. Sponge up all liquids and dry touch area thoroughly with a clean microfiber cloth. Wipe glass surface clean, disconnect power supply circuit breaker for 60 seconds, reconnect and hold Pause/Lock key for 5 seconds.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Tangential cooling fan failure Er04; electronics cooling blower tachometer signal absent or speed falls below minimum RPM.
On Haier ovens utilizing Chef@Home multi-zone convection system, high-precision cavity thermal probe, and I-Message electronic controller: Jammed cross-flow fan impeller, open fan motor winding (~180–350 Ω), or defective Hall effect tachometer sensor.
Inspect tangential fan above cavity for free spin. Measure fan motor coil resistance (~180–350 Ω across terminals). Check Hall sensor 5V DC supply. Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Pyrolysis door lock latch failure Er05; motorized latch mechanism fails to engage door interlock within 60 seconds of cycle start.
On Haier ovens powered by Chef@Home multi-zone convection system, high-precision cavity thermal probe, and I-Message electronic controller: Misaligned door catch hook, open synchronous latch motor coil (~2.0–4.5 kΩ), or defective lock microswitch.
Check door alignment and latch hook entry. Measure door lock synchronous motor resistance (~2.0–4.5 kΩ). Verify cam microswitch continuity when latched. Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Pyrolysis door unlock timeout Er06; motorized latch mechanism fails to retract after cavity cools below safe temperature (~250°C).
On Haier ovens utilizing Chef@Home multi-zone convection system, high-precision cavity thermal probe, and I-Message electronic controller: Jammed mechanical cam linkage, defective unlock feedback switch, or power failure during unlock stroke.
Confirm cavity has fully cooled to room temperature. Manually actuate unlock cam mechanism from upper service access. Replace latch motor assembly. Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds.
On Haier ovens featuring Chef@Home multi-zone convection system, high-precision cavity thermal probe, and I-Message electronic controller: Liquid grease ingress inside meat probe jack socket on cavity wall, punctured probe silicone cord, or shorted connector.
Unplug meat probe from wall jack. Clean socket contact pins with isopropyl alcohol. Measure probe resistance with multimeter (~10 kΩ or ~1000 Ω depending on type). Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Power relay board communication lost Er08; display interface loses serial handshake with heating element relay power module.
On Haier ovens utilizing Chef@Home multi-zone convection system, high-precision cavity thermal probe, and I-Message electronic controller: Disconnected or heat-damaged communication ribbon cable, power board transformer failure, or lost 12V DC rail.
Inspect multi-conductor cable connecting display to rear relay board. Reseat connectors and verify 12V DC and 5V DC power rails with voltmeter. Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Stuck touch control key error Er09; capacitive glass touch pad detects continuous activation for longer than 30 seconds.
On Haier ovens powered by Chef@Home multi-zone convection system, high-precision cavity thermal probe, and I-Message electronic controller: Grease film, liquid spillage, metal pot handle resting against touch glass, or damaged capacitive sensing spring.
Clean and dry the entire glass control fascia with microfiber cloth and glass cleaner. Ensure no objects touch glass. Power cycle breaker if persists. Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Electronics housing ambient overtemperature Er15; control board internal thermal sensor detects temperature exceeding 85°C.
On Haier ovens utilizing Chef@Home multi-zone convection system, high-precision cavity thermal probe, and I-Message electronic controller: Failed cooling fan motor, blocked cabinetry ventilation slots, or thermal insulation blanket compression.
Verify cooling fan operates during bake cycle. Ensure cabinet has minimum 50 mm rear air ventilation gap. Check board NTC sensor calibration. Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds.
Electronic Control Board (PCB) & Bus Communications
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Microcontroller flash memory checksum fault Er20; internal processor ROM memory block verification fails at boot.
On Haier ovens powered by Chef@Home multi-zone convection system, high-precision cavity thermal probe, and I-Message electronic controller: Mains power surge damage to microcontroller flash sector, electrical line noise, or incomplete firmware programming.
Power down at breaker for 15 minutes to clear RAM. If error reoccurs upon power restoration, main control module requires replacement. Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds.
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Microcontroller flash / EEPROM checksum error ER20; induction power board parameter registers corrupted.
On Haier cooktops featuring I-Move Series / Multi Switch induction power board, high-frequency coil induction, and capacitive sensor glass interface: High-voltage inductive spike from cooking zone switching, mains supply transient, or memory cell fatigue.
Power off cooker circuit breaker for 10 minutes to reset microcomputer registers. If error persists on power up, replace induction power board. Wipe glass surface clean, disconnect power supply circuit breaker for 60 seconds, reconnect and hold Pause/Lock key for 5 seconds.
Electronic Control Board (PCB) & Bus Communications
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Low-voltage DC power supply ripple fault Er21; 5V DC or 12V DC power bus voltage drops below operating threshold.
On Haier ovens utilizing Chef@Home multi-zone convection system, high-precision cavity thermal probe, and I-Message electronic controller: Dried electrolytic filter capacitors on switch-mode power supply, shorted optocoupler, or excessive relay coil current draw.
Measure DC voltages across power supply test points with multimeter (must read clean 5.0V DC and 12.0V DC without AC ripple). Replace power board if low. Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds.
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Ambient electronics housing temperature exceeded ER21; internal temperature inside cooktop enclosure exceeds 85°C.
On Haier cooktops powered by I-Move Series / Multi Switch induction power board, high-frequency coil induction, and capacitive sensor glass interface: Blocked cabinetry ventilation intake/exhaust, pyrolytic oven installed underneath running a self-clean cycle, or failed cooling fan.
Turn off all cooking zones and allow 20 minutes to cool. Verify cabinetry ventilation slots are unobstructed. Check cooling fan rotation. Wipe glass surface clean, disconnect power supply circuit breaker for 60 seconds, reconnect and hold Pause/Lock key for 5 seconds.
Electronic Control Board (PCB) & Bus Communications
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Touch control panel matrix evaluation error Er22; touch controller detects invalid internal scanning line pattern.
On Haier ovens featuring Chef@Home multi-zone convection system, high-precision cavity thermal probe, and I-Message electronic controller: Moisture condensation between glass panel and touch PCB, mechanical displacement of touch springs, or controller IC defect.
Dismantle fascia panel and clean/dry glass inner surface. Ensure all conductive spring contacts sit centered on designated capacitive pad zones. Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds.
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Touch control evaluation hardware fault ER22; capacitive sensing integrated circuit detects an internal analog front-end failure.
On Haier cooktops utilizing I-Move Series / Multi Switch induction power board, high-frequency coil induction, and capacitive sensor glass interface: Conductive liquid leakage inside the chassis onto touch sensor PCB, broken capacitive spring pin, or static discharge damage.
Open hob housing. Inspect touch sensor PCB for liquid stains or corrosion. Clean contacts with isopropyl alcohol. Replace touch PCB if hardware damaged. Wipe glass surface clean, disconnect power supply circuit breaker for 60 seconds, reconnect and hold Pause/Lock key for 5 seconds.
Electronic Control Board (PCB) & Bus Communications
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Appliance variant model configuration error Er31; EEPROM parameters do not match installed hardware options (rotisserie, pyro, steam).
On Haier ovens utilizing Chef@Home multi-zone convection system, high-precision cavity thermal probe, and I-Message electronic controller: Unprogrammed replacement PCB installed, incorrect service code entered during board replacement, or memory corruption.
Enter factory diagnostic mode and input the 16-digit variant configuration code from the oven side rating label. Confirm and store settings. Touch Settings menu on display, select System Reset, hold confirmation checkmark for 5 seconds, or power cycle breaker for 60 seconds.