Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Critical freezer high temperature alarm AL01; freezer compartment temperature has risen above safe threshold of -9°C.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Water dispenser filter expiration / flow timeout alarm AL02; water purification filter cartridge life limit or fill slow rate detected.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water filling timeout alarm AL05; wash tank does not fill to operating level within program timeout limit.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Interface display communication error E0; temperature control panel loses serial link with master power PCB.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water fill solenoid valve circuit fault E01; power board detects open circuit across inlet solenoid coil.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Door interlock error E01; appliance refuses to commence wash cycle because the door latch contact is not verified.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water inlet fill failure E1; appliance detects no incoming water flow into sump after opening fill valve.
Haier I-Move Series / Multi Switch Precision Induction Hob: Touch sensor zone covered by object or liquid E1; continuous conductive activation detected on control glass for >10 seconds.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Refrigerator compartment temperature sensor fault E1; fresh food section thermistor circuit open or shorted.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Fill meter pulse count error E02; turbine sensor signals water fill but pulse frequency is erratic or dropping out.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Process air duct NTC sensor error E02; thermistor signal indicates circuit open, short, or temperature out of operating range.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water inlet fill timeout E02; tub does not reach the minimum operating water level within 210 seconds of valve energization.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier I-Move Series / Multi Switch Precision Induction Hob: Induction cooking zone coil overheat E2; NTC temperature sensor beneath ceramic glass detects temperature exceeding 240°C.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Freezer compartment temperature sensor malfunction E2; low-temperature NTC thermistor circuit open or short-circuited.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Door / lid lock failure E2; machine does not engage lock solenoid or detects door open during cycle start.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Maximum drying cycle time exceeded E03; machine aborts cycle after running for 210 minutes without laundry reaching target dryness.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water evacuation fault E03; machine aborts cycle with water remaining in drum after 180 seconds of drain pump operation.
Haier I-Move Series / Multi Switch Precision Induction Hob: Induction power board IGBT heatsink overtemperature E3; power transistor heatsink temperature exceeds 95°C safety shutoff.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Evaporator defrost temperature sensor fault E3; defrost termination NTC thermistor out of calibrated ohmic range.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier I-Move Series / Multi Switch Precision Induction Hob: Induction coil temperature sensor circuit fault E4; coil center NTC thermistor reads open circuit or shorted.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water fill timeout E4; water does not reach target level within 8 minutes of starting fill cycle.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water temperature sensor measurement anomaly E05; NTC probe signal resistance indicates temperature below -5°C or above 90°C.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Drum motor drive failure E06; motor hums but fails to rotate the drum, or drive motor trips on thermal overload.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Humidity sensor communication error E6; crisper drawer moisture and relative humidity module signal loss.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Drum rotation sensor speed feedback missing E07; controller does not detect drum movement during program run.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor drive tachometer fault E07; drum does not rotate or motor starts at uncontrolled high speed then immediately stops.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Wash circulation pump failure E7; motor does not rotate, tachometer feedback is absent, or run capacitor is open.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Move Series / Multi Switch Precision Induction Hob: Cooling fan failure E7; internal induction generator cooling fan motor stalled, disconnected, or zero RPM feedback.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Automatic ice maker mold temperature sensor error E7; ice tray thermistor reading out of bounds during freezing cycle.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor drive inverter module overcurrent E7; drive electronics trip on thermal overload or excessive current draw.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Flow-through heater circuit open E08; water temperature does not increase during heated wash stage.
Immersion / Air Heating Element & Klixon Thermostat
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Automatic ice maker ejection motor stall E8; ice tray harvest mechanism fails to complete home position cycle within 3 minutes.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Drum motor drive semiconductor failure E09; motor triac shorted or direction reversing relay contacts burned on control PCB.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor drive electronic fault E09; power board detects shorted motor triac or inverter IGBT phase breakdown.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Move Series / Multi Switch Precision Induction Hob: Internal bus communication failure E9; touch control panel loses data communication with induction power module.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: High temperature warming warning E9; fresh food compartment temperature exceeds +12°C continuously for over 2 hours.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Moisture sensing conductivity circuit error E10; sensor bars in door opening read open circuit or shorted to chassis ground.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Program selector / drum position sensor error E10; dial input signal unrecognized or top-loader drum positioning sensor missing.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Exhaust air temperature overheat E11; air temperature leaving the drum exceeds 80°C triggering thermal protection.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Washer-dryer drying heating fault E11; air heating duct fails to reach temperature or dryer thermistor open circuit.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Serial communication timeout E12; display console fails to exchange data telegrams with main chassis power board.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Washer-dryer ventilation error E12; air circulation blower motor stall or drying auxiliary controller communication loss.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Bus communication fault E13; user interface display panel loses serial handshake with main chassis power board.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Flowmeter signal missing during fill E14; pressure switch senses water rising in tub but zero flowmeter impulses arrive at PCB.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Condensate lift pump motor fault E14; pump fails to lift water from bottom collector to upper reservoir.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Wash water heating failure E14; water temperature does not rise after 20 minutes of active wash program operation.
Immersion / Air Heating Element & Klixon Thermostat
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Microcontroller memory failure E15; main control module detects an invalid EEPROM checksum or unconfigured firmware parameter.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water softener regeneration valve fault E16; salt chamber regeneration solenoid open-circuit or shorted on power board.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Heating element earth insulation leak E16; appliance trips residual current device (RCD / breaker) or detects stray current to chassis ground.
Immersion / Air Heating Element & Klixon Thermostat
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor speed signal frequency anomaly E17; tachometer pulse cadence does not match inverter drive excitation frequency.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Power supply voltage or frequency fault E18; AC mains input deviates outside allowable 190V–255V operating window.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: AC mains power supply out of limits E18; voltage fluctuates outside 185V–260V AC or frequency deviates from 50/60 Hz.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Electronic pressure sensor calibration fault E20; signal frequency received from the analog pressure transducer is out of valid bounds.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water level sensor drift E21; water column pressure rises unexpectedly while solenoid inlet valves are de-energized.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Siphoning drain detection E22; water level drops continuously during active wash fill cycle without pump activation.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Defrost heating circuit failure Ed; evaporator defrost heater fails to terminate cycle within programmed maximum runtime.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Evaporator fan rotor stall / hardware trip EF; fan motor overcurrent detected by motor driver circuitry.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Cavity overtemperature condition Er03; cavity temperature exceeds 320°C in standard baking or 520°C in pyrolytic clean mode.
Immersion / Air Heating Element & Klixon Thermostat
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Pyrolysis door lock latch failure Er05; motorized latch mechanism fails to engage door interlock within 60 seconds of cycle start.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Power relay board communication lost Er08; display interface loses serial handshake with heating element relay power module.
Immersion / Air Heating Element & Klixon Thermostat
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Low-voltage DC power supply ripple fault Er21; 5V DC or 12V DC power bus voltage drops below operating threshold.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Touch control evaluation hardware fault ER22; capacitive sensing integrated circuit detects an internal analog front-end failure.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Power board configuration data corrupted ER31; generator module variant coding table does not match cooktop model setup.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Display console temperature sensor fault Er36; on-board thermistor on user interface board reads out of range.
Haier I-Move Series / Multi Switch Precision Induction Hob: Touch board ambient NTC sensor shorted ER36; temperature sensor on user interface PCB reads short-circuit to ground.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: LIN-bus communication error Er47; internal local interconnect network link between touch interface and power module drops packets.
Immersion / Air Heating Element & Klixon Thermostat
Haier I-Move Series / Multi Switch Precision Induction Hob: LIN-Bus communication between touch controller and power inverter module missing ER47; transmission timeout error.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Move Series / Multi Switch Precision Induction Hob: Cooking coil temperature sensor disconnected F0; generator board detects open circuit on temperature feedback line.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: User interface board communication failure F0; display module cannot communicate with main power relay board.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Variable frequency inverter compressor communication fault F0; main control PCB loses PWM / UART handshake with inverter driver board.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Air intake temperature sensor fault F1; front air temperature probe disconnected or reading outside allowable bounds.
Haier I-Move Series / Multi Switch Precision Induction Hob: Cooking coil temperature sensor short circuit F1; measured probe resistance drops to near zero ohms.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Freezer evaporator fan motor malfunction F1; low-voltage brushless DC circulation fan stalled or tachometer feedback missing.
Compressor Motor Windings (Run/Start) & Defrost Heater
Haier I-Move Series / Multi Switch Precision Induction Hob: Communication loss to induction generator module F2; main controller loses sync with left or right power inverter board.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Refrigerator compartment air circulation fan fault F2; fresh food multi-airflow fan fails rotation speed verification.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Temperature sensor probe circuit open F3; sensor signal resistance is infinite, halting heating cycle.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Condenser cooling fan motor failure F3; rear machine compartment fan stalls or fails thermal heat extraction.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Condensate evacuation pump failure F4; water level switch in collection sump remains active after pump run cycle.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Temperature sensor probe short circuit F4; sensor signal resistance is near zero ohms, preventing temperature control.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Heating circuit failure F4; water does not heat up during wash phase within allotted cycle time.
Immersion / Air Heating Element & Klixon Thermostat
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Motor / compressor inverter communication timeout F5; main PCB loses data link with drive inverter module.
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Cooling fan hall sensor feedback missing F5; electronics cooling fan is commanded on but speed sensor sends zero RPM.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Motorized air damper baffle malfunction F5; motorized cold air shutter fails to reach calibrated open or closed position.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Auxiliary heat-pump cooling fan fault F6; compressor compartment ventilation fan motor stalled or disconnected.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: Refrigerant switching valve error F6; bistable 3-way solenoid valve fails to direct refrigerant between fridge and freezer circuits.
Haier I-Move Series / Multi Switch Precision Induction Hob: Mains supply frequency out of limits F7; AC power line frequency falls outside 47 Hz–63 Hz operating window.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor drive board communication / synchronization fault F7; inverter driver board fails to command motor rotation.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Move Series / Multi Switch Precision Induction Hob: Continuous heating safety timer shutoff F8; cooking zone automatically powers off after exceeding maximum continuous runtime limit.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Meat probe temperature limit exceeded F8; core probe signal indicates temperature above maximum safe reading.
Immersion / Air Heating Element & Klixon Thermostat
Haier I-Move Series / Multi Switch Precision Induction Hob: Induction coil current sensor calibration failure F9; current transformer sensing circuit fails zero-offset balance test at power up.
Immersion / Air Heating Element & Klixon Thermostat
Haier Series 4 / 6 Chef@Home & I-Message Connected Oven: Motorized door latch switch timing error F9; latch motor runs but lock switch does not transition within expected time window.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Water level frequency sensor abnormal FA; water level reading absent or outside valid frequency bounds (~20–40 kHz).
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Inverter drive communication loss FC0; main control module loses communication handshake with motor inverter module.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Display board communication timeout FC1; user interface touch panel fails to synchronize with system controller.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: EEPROM variant configuration parameter mismatch FC2; model code programming does not match installed chassis hardware.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Haier I-Move Series / Multi Switch Precision Induction Hob: Mains supply undervoltage / phase missing alert U; cooktop detects open circuit on secondary phase or voltage under 170V AC.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Drum motor drive semiconductor failure E09; motor triac shorted or direction reversing relay contacts burned on control PCB.
On Haier tumble dryers utilizing I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Heavy drum overload inducing high stall current, inductive voltage spikes from motor reversing, or PCB component fatigue.
Inspect control PCB for burned traces or cracked solder joints around motor relays. Test triac anode-cathode resistance with multimeter (must not be 0 Ω). Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor drive electronic fault E09; power board detects shorted motor triac or inverter IGBT phase breakdown.
On Haier washing machines featuring Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Motor overload, carbon brush sparking surge, shorted stator windings, or thermal fatigue of semiconductor junction.
Inspect motor carbon brushes (replace if length <15 mm). Test motor windings for insulation breakdown to ground (>10 MΩ). Replace power module if triac is shorted. Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
On Haier dishwashers featuring I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Grease film coating optical lenses in sump, disconnected sensor plug, or burned infrared transmitter LED.
Clean optical turbidity sensor prism inside sump using soft cloth and degreaser. Check 5V DC power supply on sensor connector pins. Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
Electronic Control Board (PCB) & Bus Communications
Haier I-Move Series / Multi Switch Precision Induction Hob: Internal bus communication failure E9; touch control panel loses data communication with induction power module.
On Haier cooktops powered by I-Move Series / Multi Switch induction power board, high-frequency coil induction, and capacitive sensor glass interface: Disconnected or pinched data ribbon cable, oxidized pin terminals, or power supply failure on induction board.
Inspect internal communication cable between touch panel and generator board. Reseat both ends firmly and verify low-voltage DC rails. Wipe glass surface clean, disconnect power supply circuit breaker for 60 seconds, reconnect and hold Pause/Lock key for 5 seconds.
Haier Cube 90 / FD 70 / 3D & 4D Total No Frost Refrigerator: High temperature warming warning E9; fresh food compartment temperature exceeds +12°C continuously for over 2 hours.
On Haier refrigeration units featuring Fresher Shield Total No-Frost inverter cooling, multi-airflow tower, and ABT antibacterial preservation system: Incomplete door seal contact, defective magnetic reed switch, or prolonged door ajar state.
Check door gasket alignment using paper slip test. Test magnetic reed switch continuity with magnet near hinge. Seal leaks and clear alarm: Press and hold Fridge Temp and Freezer Temp keys together for 6 seconds until long beep confirms electronic board reset.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water diverter valve timeout E10; motorized spray arm alternator disc fails to reach requested position microswitch contact.
On Haier dishwashers utilizing I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Jammed ceramic disc in diverter body, open synchronous drive motor winding (~4–9 kΩ), or defective microswitch.
Measure synchronous motor winding resistance (~4–9 kΩ). Verify cam microswitch continuity when actuated. Inspect diverter disc for foreign matter. Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Moisture sensing conductivity circuit error E10; sensor bars in door opening read open circuit or shorted to chassis ground.
On Haier tumble dryers powered by I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Insulating fabric softener residue coating the stainless steel sensor strips, disconnected lead, or grounded wire.
Clean both stainless steel moisture sensor bars below door seal with vinegar and cloth to remove wax film. Check sensor wire continuity to PCB. Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Program selector / drum position sensor error E10; dial input signal unrecognized or top-loader drum positioning sensor missing.
On Haier washing machines utilizing Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Oxidized rotary selector contacts, misaligned reed/Hall drum position sensor, or disconnected harness.
Clean rotary switch contacts with contact cleaner. On top-loaders, verify drum magnet alignment with Hall sensor on tub outer shell. Check continuity. Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Exhaust air temperature overheat E11; air temperature leaving the drum exceeds 80°C triggering thermal protection.
On Haier tumble dryers utilizing I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Heavily choked condenser unit, clogged exhaust ductwork, or blocked rear air intake grille behind machine.
Allow appliance to cool for 30 minutes. Remove and wash heat exchanger condenser. Test safety thermostat continuity with a multimeter. Ensure machine has minimum 10 cm rear clearance from wall. Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Washer-dryer drying heating fault E11; air heating duct fails to reach temperature or dryer thermistor open circuit.
On Haier washer-dryers with Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Tripped manual reset safety thermostat (Klixon), burned drying heating element (~25–35 Ω), or defective duct NTC (~20 kΩ).
Check Klixon push-button on top of drying duct. Measure drying element resistance (~25–35 Ω). Test drying duct NTC sensor (~20 kΩ at 25°C). Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Software sequence logic fault E12; program execution controller detects an illegal cycle state or memory jump.
On Haier dishwashers powered by I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Mains supply noise surge, defective microcontroller clock crystal, or corrupted program ROM memory bank.
Perform full power reset by unplugging unit for 15 minutes. Verify line filter capacitor health. If error reappears immediately, replace control board. Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Serial communication timeout E12; display console fails to exchange data telegrams with main chassis power board.
On Haier tumble dryers powered by I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Disconnected or pinched data ribbon cable, corroded edge connectors, or damaged low-voltage DC power supply on board.
Inspect wiring harness connecting display module to power PCB. Reseat connectors and check pin continuity. Test 5V DC and 12V DC test pads. Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Washer-dryer ventilation error E12; air circulation blower motor stall or drying auxiliary controller communication loss.
On Haier washer-dryers with Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Fluff build-up jamming centrifugal fan impeller, open fan motor winding (~60–120 Ω), or defective drying PCB.
Dismantle drying duct assembly and clear lint obstructions from impeller. Measure fan motor winding (~60–120 Ω). Verify power supply plug. Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Condensate collection container full alert E13; water reservoir float switch trips and halts program execution.
On Haier tumble dryers utilizing I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Water container completely filled with extracted condensate, stuck microswitch lever, or slime coating the float.
Empty condensate drawer completely and re-insert firmly until it clicks. If code persists empty, clean sump float switch chamber in lower rear. Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Bus communication fault E13; user interface display panel loses serial handshake with main chassis power board.
On Haier washing machines featuring Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Corroded ribbon cable edge connectors, electrical noise spikes, or defective 5V DC low-voltage rail on main board.
Inspect wiring harness between display and main power board for continuity and terminal crimp tension. Verify 5V DC and 12V DC test points on power PCB. Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Flowmeter signal missing during fill E14; pressure switch senses water rising in tub but zero flowmeter impulses arrive at PCB.
On Haier dishwashers featuring I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Jammed impeller wheel in side air-break matrix, disconnected reed switch sensor board, or broken wire harness.
Inspect flowmeter connector at left side water jacket. Test reed switch closing action with small magnet and ohmmeter. Replace sensor circuit board. Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Condensate lift pump motor fault E14; pump fails to lift water from bottom collector to upper reservoir.
On Haier tumble dryers powered by I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Open pump motor winding (~120–280 Ω), lint slime seizing impeller shaft, or pinched transfer hose.
Access lower rear pump compartment. Clean lint residue from impeller chamber. Measure lift pump motor winding resistance (~120–280 Ω). Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Wash water heating failure E14; water temperature does not rise after 20 minutes of active wash program operation.
On Haier washing machines powered by Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Open wash heating element (~25–30 Ω), desoldered heater relay on main PCB, or thermal fuse blown.
Disconnect element terminals. Measure heater resistance across element pins (nominal ~25–30 Ω). Inspect heater relay contacts for pitting on power PCB. Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
On Haier dishwashers powered by I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Blocked spray arm nozzles, excessive foam from incorrect detergent, or low water level from partial siphonage.
Unclip upper and lower spray arms and clear lime/debris from all jet holes. If excessive suds present, run cold rinse cycle without detergent. Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Inverter compressor driver fault E15; heat-pump variable speed compressor trips on overcurrent or locked rotor protection.
On Haier tumble dryers utilizing I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Low suction refrigerant pressure causing compressor piston seizure, defective inverter board, or shorted BLDC windings (~5–15 Ω).
Disconnect compressor plug. Measure resistance between all 3 compressor pins (must be balanced ~5–15 Ω phase-to-phase). Test insulation to ground (>10 MΩ). Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Microcontroller memory failure E15; main control module detects an invalid EEPROM checksum or unconfigured firmware parameter.
On Haier washing machines featuring Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: AC mains voltage transient surge, corrupted non-volatile memory cell, or replacement blank module installed.
Attempt hard power cycle by removing mains plug for 10 minutes. If error returns, re-program configuration code or replace pre-programmed control module. Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Water softener regeneration valve fault E16; salt chamber regeneration solenoid open-circuit or shorted on power board.
On Haier dishwashers featuring I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Open solenoid coil on water softener matrix (~2.0–3.5 kΩ), corroded spade terminals, or shorted driver triac on PCB.
Gain access to salt reservoir assembly underneath sump. Measure regeneration valve solenoid resistance (~2.0–3.5 kΩ). Inspect wiring terminals. Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Heat pump evaporator coil freezing alert E16; evaporator temperature drops below -5°C during active drying cycle.
On Haier tumble dryers powered by I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Blocked airflow starving evaporator of warm air, low refrigerant charge (gas leak), or defective capillary tube.
Clean all filters and condenser package completely to restore full process airflow. If evaporator remains iced with clean airflow, professional refrigeration service is required. Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Heating element earth insulation leak E16; appliance trips residual current device (RCD / breaker) or detects stray current to chassis ground.
On Haier washing machines powered by Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Micro-cracked stainless steel element sheath allowing wash water into magnesium oxide core (>1 mA leakage).
Measure element insulation resistance with 500V megohmmeter between terminal pins and earth grounding tab (nominal >10 MΩ; replace if <2 MΩ). Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: High water inlet flow / pressure fault E17; flowmeter impeller velocity exceeds maximum rate (>15 bar surge).
On Haier dishwashers utilizing I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Mains supply water hammer pressure spike, missing flow restrictor inside inlet valve, or defective flowmeter transducer.
Partially close water tap valve to regulate inlet flow rate. Install water pressure regulator if line pressure exceeds 10 bar. Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Drum drive belt breakage detected E17; tensioner pulley safety microswitch opens when belt tension is lost.
On Haier tumble dryers utilizing I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Snapped poly-V drive belt, broken tensioner return spring, or dislodged belt pulley bearing.
Remove side panel or top lid. Fit new OEM drive belt around drum and motor spindle. Route belt correctly through tensioner idler pulley. Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: Motor speed signal frequency anomaly E17; tachometer pulse cadence does not match inverter drive excitation frequency.
On Haier washing machines featuring Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Slipping drive belt, worn motor shaft bearings, loose rotor pole sensor, or defective inverter driver IC.
Check poly-V drive belt tension (replace if stretched or glazed). Spin drum manually to test bearing drag. Check tachometer signal waveform with oscilloscope. Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.
Haier I-Pro Shine / Washlogix Ultra Silence Dishwasher: Low water level during circulation E18; circulation wash pump sucks air pockets causing cavitation and pressure loss.
On Haier dishwashers powered by I-Pro Shine Ultra Silence brushless wash circulation pump, dual-zone inverter spray system, and micro-filtration: Upside-down pots trapping excessive wash water, partial siphoning through low drain hose, or foaming detergent.
Arrange hollow dishes so they drain freely. Ensure drain hose loop is at least 65 cm above floor. Pour 2 liters of water in tub and reset. Press Power button off, hold Half Load and Start buttons together while powering on until diagnostic test mode 01 displays, then power off.
Haier I-Pro Series 7 / 9 Dual Inverter Heat Pump Dryer: Power supply voltage or frequency fault E18; AC mains input deviates outside allowable 190V–255V operating window.
On Haier tumble dryers powered by I-Pro Series Dual Inverter heat-pump circuit, sensor-dry thermistor array, and reverse-tumble motor control: Mains line voltage drop under heavy household load, generator frequency variation, or worn filter capacitors.
Verify wall socket voltage with multimeter under active load (must be 230V ±10%). Do not operate dryer on light-gauge extension cables. Turn dial to Warm Air program, press Dry Level and Time Dry together for 5 seconds until beep sounds, then return to Power Off.
Haier I-Pro Series 3 / 5 / 7 Direct Motion Beltless Washer: AC mains power supply out of limits E18; voltage fluctuates outside 185V–260V AC or frequency deviates from 50/60 Hz.
On Haier washing machines utilizing Direct Motion beltless electromagnetic direct-drive motor, ABT antibacterial zinc gasket, and Smart Dual Spray: Heavy grid brownout, electrical generator distortion, loose wall outlet wiring, or worn power PCB filtering capacitors.
Measure line voltage and frequency at wall receptacle using multimeter under load (must be 230V ±10%, 50/60 Hz). Avoid multi-gang extension leads. Power on, turn knob to Spin cycle, hold Delay and Temp buttons together for 5 seconds until 'tSt' or drum calibrates, then power off.