Fagor Innova Total No Frost / FFA Multi-Airflow Refrigerator: High temperature alarm in freezer compartment AL01; internal temperature rises above -9°C and audible buzzer sounds.
Compressor Motor Windings (Run/Start) & Defrost Heater
Fagor Innova Total No Frost / FFA Multi-Airflow Refrigerator: Door open warning signal persistent AL02; acoustic door alarm sounds and interior light remains energized with door shut.
Compressor Motor Windings (Run/Start) & Defrost Heater
Fagor Innova Induction / IF / 2IF / 3IF High-Power Cooktop: Auto-Stop safety timeout triggered AS; all induction cooking zones shut down automatically after liquid spillover or prolonged cooking.
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Water fill timeout d01; appliance fails to fill with adequate water volume within 4 minutes of program launch.
Fagor Innova / SFS Condensation & Heat Pump Tumble Dryer: Condensation water reservoir full d01; dryer halts cycle and triggers acoustic water tank warning.
Fagor Innova Total No Frost / FFA Multi-Airflow Refrigerator: Fridge compartment temperature sensor failure d01; internal cold air temperature fluctuates uncontrollably.
Compressor Motor Windings (Run/Start) & Defrost Heater
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Water intake timeout d01; tub water level does not reach wash threshold within 6 minutes of valve opening.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Fagor Innova / SFS Condensation & Heat Pump Tumble Dryer: Condensate lift pump failure d02; water fails to pump up into collection tank and accumulates in chassis sump base.
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Drain pump timeout d02; water remains in the drum after 4 minutes of continuous drain pump operation.
Fagor Innova Total No Frost / FFA Multi-Airflow Refrigerator: Ambient room temperature sensor error d03; unit cannot adapt cooling cycles to room climate variations.
Compressor Motor Windings (Run/Start) & Defrost Heater
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Heating circuit timeout d03; water temperature fails to increase by more than 2°C within 30 minutes of wash cycle.
Immersion / Air Heating Element & Klixon Thermostat
Fagor Innova / SFS Condensation & Heat Pump Tumble Dryer: Drum motor drive stall d04; drive motor hums loudly or fails to turn the drum loaded with damp laundry.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Fagor Innova Total No Frost / FFA Multi-Airflow Refrigerator: Evaporator circulation fan motor failure d05; cold air does not circulate into the refrigeration compartments.
Compressor Motor Windings (Run/Start) & Defrost Heater
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Wash motor overcurrent cutoff d06; power electronic controller trips due to excessive electric current draw by the circulation pump.
Fagor Innova Total No Frost / FFA Multi-Airflow Refrigerator: Motorized air damper flap malfunction d06; fresh food compartment either freezes contents or remains too warm.
Compressor Motor Windings (Run/Start) & Defrost Heater
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Motor tachometer signal fault d06; drum does not rotate or motor starts then immediately stops after speed feedback loss.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Fagor Innova Total No Frost / FFA Multi-Airflow Refrigerator: Condenser cooling fan motor failure d07; compressor overheats, trips overload protector, and cooling stops.
Compressor Motor Windings (Run/Start) & Defrost Heater
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Door interlock safety fault d07; cycle will not begin because electronic module cannot confirm closed door contact.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Alternating spray distributor valve motor fault d08; wash water does not alternate between upper and lower spray arms.
Fagor Innova Total No Frost / FFA Multi-Airflow Refrigerator: Inverter compressor drive or communication failure d08; compressor fails to start or rapidly cuts out after clicking.
Compressor Motor Windings (Run/Start) & Defrost Heater
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Drum rotation reversal fault d08; drum rotates only in one direction during wash tumble phases.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Internal control bus communication error d09; display fascia loses synchronism with main hydraulic power board.
Fagor Innova Total No Frost / FFA Multi-Airflow Refrigerator: Automatic ice maker mechanism failure d09; ice cubes are not ejected into storage bucket or water fill fails.
Compressor Motor Windings (Run/Start) & Defrost Heater
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Continuous uncontrolled water fill d10; water continues entering appliance after target fill level is achieved.
Fagor Innova Total No Frost / FFA Multi-Airflow Refrigerator: Main electronic control PCB memory error d10; unit resets intermittently or fails to execute temperature programs.
Compressor Motor Windings (Run/Start) & Defrost Heater
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Abnormal heating in rinse cycle d11; water heats unexpectedly during cold water rinse phases.
Immersion / Air Heating Element & Klixon Thermostat
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Residual water detected after pumpout d12; pressure sensor fails to register empty tub state after drain sequence.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Wash pump cavitation / water fill discrepancy d14; circulation motor draws irregular current due to aerated water foam.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Fagor Innova / SFS Condensation & Heat Pump Tumble Dryer: Inverter drum motor communication loss d15; variable speed motor controller fails to respond to main microprocessor commands.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Electronic pressure switch frequency fault d15; analog level sensor outputs erratic frequency signal to main PCB.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Fagor Innova / SFS Condensation & Heat Pump Tumble Dryer: Door latch open during cycle d16; cycle pauses immediately as door contact microswitch opens during active operation.
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Inverter module bus link error d16; main controller loses communication with 3-phase BLDC motor inverter card.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Mains supply frequency out of bounds d18; line frequency deviates outside 47 Hz – 63 Hz operational tolerances.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Fagor Innova / SFS Condensation & Heat Pump Tumble Dryer: User interface display communication timeout d20; display panel loses serial synchronization with main power controller.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Water distributor stepper motor fault d20; water stream cannot be directed to the selected additive compartment.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Display to power board communication loss d21; control panel lights flash or display is completely blank while machine halts.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Washer-dryer ventilation fan failure d24; process air blower fails to spin during drying phase.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Door unlock timeout at cycle completion d27; door remains securely locked after wash program finishes and drum stops.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Fagor Innova Induction / IF / 2IF / 3IF High-Power Cooktop: Touch control panel link failure E1; induction zones flash 'E1' and power sliders do not respond to fingertip touch.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Fagor Innova Induction / IF / 2IF / 3IF High-Power Cooktop: Induction coil temperature sensor fault E2; zone display flashes 'E2' and cuts power to prevent glass overheating.
Fagor Innova Induction / IF / 2IF / 3IF High-Power Cooktop: Mains undervoltage protection trip E4; cooktop shuts down zones because electrical line voltage drops below 180 V RMS.
Fagor Innova Induction / IF / 2IF / 3IF High-Power Cooktop: Electronics cooling fan motor failure E7; cooktop detects stalled or disconnected fan motor during boot diagnostics.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Fagor Innova Induction / IF / 2IF / 3IF High-Power Cooktop: Pan detection resonant circuit fault E8; zone display flashes 'E8' and fails to acknowledge presence of magnetic cookware.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Fagor Innova Induction / IF / 2IF / 3IF High-Power Cooktop: Microcontroller configuration jumper / EEPROM mismatch E9; power board variant coding does not match user interface.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Fagor Masterchef / Innova / 6H Pyrolytic Multi-Function Oven: Main power board communication timeout Er06; display module loses digital data exchange with the internal power relay board.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Fagor Masterchef / Innova / 6H Pyrolytic Multi-Function Oven: Steam boiler water evacuation fault Er10; drain pump fails to pump residual water out of the steam boiler.
Fagor Masterchef / Innova / 6H Pyrolytic Multi-Function Oven: Upper heating grill element relay fault Er11; top grill element glows red continuously without cooking program active.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Fagor Masterchef / Innova / 6H Pyrolytic Multi-Function Oven: Circular convection fan heating element open circuit Er13; convection forced air mode blows air without heating.
Immersion / Air Heating Element & Klixon Thermostat
Fagor Innova Induction / IF / 2IF / 3IF High-Power Cooktop: No cookware detected or unsuitable pan base F0; zone display alternates 'F0' and heating output is withheld.
Fagor Innova / Elegance / Fascia / FE-810 Inverter Washing Machine: Basque electronic platform water fill fault F01; water inlet solenoid valve fails to supply water within allocated timeout.
Fagor Innova Induction / IF / 2IF / 3IF High-Power Cooktop: User interface keyboard communication timeout F1; touch control panel loses synchronization with induction power board.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Fagor Innova Total No Frost / FFA Multi-Airflow Refrigerator: Refrigerator compartment air temperature probe failure F2; display alternates temperature and fault code.
Compressor Motor Windings (Run/Start) & Defrost Heater
Fagor Masterchef / Innova / 6H Pyrolytic Multi-Function Oven: Tangential cooling fan speed error F03; fan operates at insufficient RPM or tachometer signal is missing.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Fagor Innova Induction / IF / 2IF / 3IF High-Power Cooktop: High voltage surge protection active F3; power board shuts down induction frequency generation to prevent semiconductor destruction.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Fagor Innova Total No Frost / FFA Multi-Airflow Refrigerator: Freezer compartment air temperature probe failure F3; freezer temperature control loses precision and warning flashes.
Compressor Motor Windings (Run/Start) & Defrost Heater
Fagor Masterchef / Innova / 6H Pyrolytic Multi-Function Oven: Pyrolytic latch microswitch position error F05; position feedback microswitch does not toggle when door unlatches.
Fagor Innova Total No Frost / FFA Multi-Airflow Refrigerator: Evaporator fan motor feedback failure F5; fan motor does not achieve target operating RPM during cooling demand.
Compressor Motor Windings (Run/Start) & Defrost Heater
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Continuous water entry / water level safety fault F6; water continues to rise after program attempts shut-off.
Mechanical Pressure Switch Contacts / Inductive Frequency Sensor
Fagor Innova Induction / IF / 2IF / 3IF High-Power Cooktop: Short-circuited IGBT power semiconductor F6; circuit breaker trips with an audible pop when zone is turned on.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Fagor Innova Total No Frost / FFA Multi-Airflow Refrigerator: Door display communication fault F6; user interface loses digital connection to the main power board.
Compressor Motor Windings (Run/Start) & Defrost Heater
Fagor Innova Induction / IF / 2IF / 3IF High-Power Cooktop: Cooling fan blocked or low RPM stall F7; electronic safety cuts zone power when fan fails to achieve operational speed.
3-Phase Motor Windings / Tacho Generator / Carbon Brushes
Fagor Innova Induction / IF / 2IF / 3IF High-Power Cooktop: Control board EEPROM calibration checksum failure F9; factory power table values are corrupted and zones will not operate.
PCB Power Supply Rails & DC Bus Filter Capacitors
Electronic Control Board (PCB) & Bus Communications
Fagor Masterchef / Innova / 6H Pyrolytic Multi-Function Oven: Pyrolytic latch microswitch position error F05; position feedback microswitch does not toggle when door unlatches.
On FAGOR ovens featuring Masterchef 6H pyrolytic thermal management, high-flow tangential cooling turbine, and digital programmer interface: Sticky microswitch actuator plunger, oxidized switch contacts, or bent actuator leaf spring.
Test microswitch continuity with a multimeter in both unlatched (~0 Ω) and latched (infinite) positions. Replace microswitch if sticky. Return function selector to 0, isolate the power distribution breaker for 60 seconds, restore power and configure the clock.
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Circulation wash motor electrical fault F5; wash pump fails to run and cycle stalls during wash stages.
On FAGOR dishwashers featuring Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Open motor windings (~70–110 Ω), defective starting capacitor (~4 µF), or tripped motor thermal protector.
Measure wash motor winding resistance (~70–110 Ω). Check run capacitor rating with a capacitance meter (~4 µF). Verify 230V AC arrival on call. Press and hold the Start/Stop key for 5 seconds until the program indicator light clears and drain pump runs, then switch off.
Fagor Innova Induction / IF / 2IF / 3IF High-Power Cooktop: Induction power stage thermal overload F5; cooling fan cannot dissipate heat quickly enough, triggering thermal power foldback.
On FAGOR cooktops utilizing Innova high-frequency induction generator, ferromagnetic pan detection resonance, and rapid booster stages: Sustained maximum power boiling across all zones simultaneously with restricted under-counter ventilation channel.
Reduce cooking zone power levels. Open cabinet doors temporarily to exhaust hot trapped air. Ensure front cooling ventilation gap is unblocked. Clear and dry cooktop surface, disconnect mains power breaker for 60 seconds, reconnect and hold Key Padlock sensor for 5 seconds.
Fagor Innova Total No Frost / FFA Multi-Airflow Refrigerator: Evaporator fan motor feedback failure F5; fan motor does not achieve target operating RPM during cooling demand.
On FAGOR refrigeration units featuring Innova Total No Frost dual-evaporator system, dynamic cooling column, and intelligent automated defrost cycle: Heavy ice build-up impeding fan blades, seized motor sleeve bushings, or defective Hall-effect RPM feedback circuit.
Manually defrost evaporator cavity. Spin fan wheel by hand to verify free movement. Measure 12V DC power and frequency on Hall tacho wire during operation. Replace fan assembly. Press and hold the Super Freeze and Alarm Mute pads together for 6 seconds until the beep confirms diagnostic memory cleared.
Fagor Eco Sensor / Innova / 1LV / 2LV Dishwasher: Continuous water entry / water level safety fault F6; water continues to rise after program attempts shut-off.
On FAGOR dishwashers featuring Eco Sensor turbidity optoelectronics, Innova hydraulic distribution, and AquaStop active leak containment: Mechanically stuck inlet valve seat, shorted triac on power board, or blocked pressure sensor hose.
Disconnect mains power and check if water stops entering (if yes, electronic triac short; if no, mechanical valve failure). Replace component. Press and hold the Start/Stop key for 5 seconds until the program indicator light clears and drain pump runs, then switch off.
Electronic Control Board (PCB) & Bus Communications
Fagor Innova Induction / IF / 2IF / 3IF High-Power Cooktop: Short-circuited IGBT power semiconductor F6; circuit breaker trips with an audible pop when zone is turned on.
On FAGOR cooktops utilizing Innova high-frequency induction generator, ferromagnetic pan detection resonance, and rapid booster stages: Collector-to-emitter semiconductor breakdown on IGBT due to voltage spike or thermal fatigue under load.
Disconnect cooktop from breaker. Disassemble power unit and test IGBTs on heatsink with multimeter on diode test (~0V = blown). Replace power module. Clear and dry cooktop surface, disconnect mains power breaker for 60 seconds, reconnect and hold Key Padlock sensor for 5 seconds.
Fagor Innova Total No Frost / FFA Multi-Airflow Refrigerator: Door display communication fault F6; user interface loses digital connection to the main power board.
On FAGOR refrigeration units featuring Innova Total No Frost dual-evaporator system, dynamic cooling column, and intelligent automated defrost cycle: Severed or pinched wires inside the top door hinge bushing, oxidized connector pins, or faulty transceiver on display PCB.
Inspect door hinge wiring harness: check each wire for breakages caused by door swinging. Clean multi-pin connectors with contact cleaner. Replace display module if wiring tests OK. Press and hold the Super Freeze and Alarm Mute pads together for 6 seconds until the beep confirms diagnostic memory cleared.
Fagor Innova Induction / IF / 2IF / 3IF High-Power Cooktop: Cooling fan blocked or low RPM stall F7; electronic safety cuts zone power when fan fails to achieve operational speed.
On FAGOR cooktops utilizing Innova high-frequency induction generator, ferromagnetic pan detection resonance, and rapid booster stages: Grease accumulation seizing fan spindle, dislodged internal sound baffle, or open motor coil winding (~40–80 Ω).
Clean fan impeller blades and bearing spindle with alcohol. Measure motor coil resistance (~40–80 Ω). Verify free spin by hand. Clear and dry cooktop surface, disconnect mains power breaker for 60 seconds, reconnect and hold Key Padlock sensor for 5 seconds.
Electronic Control Board (PCB) & Bus Communications
Fagor Innova Induction / IF / 2IF / 3IF High-Power Cooktop: Continuous pan sensing resonance failure F8; induction coil pulses loudly but cannot sustain stable magnetic field coupling.
On FAGOR cooktops utilizing Innova high-frequency induction generator, ferromagnetic pan detection resonance, and rapid booster stages: Cookware with non-uniform sandwich composite base, cracked resonance capacitor bank on power PCB, or burned Litz coil wire.
Switch to a solid heavy cast iron skillet to test coil coupling. Inspect resonance capacitors on PCB for bulging or scorch marks. Clear and dry cooktop surface, disconnect mains power breaker for 60 seconds, reconnect and hold Key Padlock sensor for 5 seconds.
Electronic Control Board (PCB) & Bus Communications
Fagor Innova Induction / IF / 2IF / 3IF High-Power Cooktop: Control board EEPROM calibration checksum failure F9; factory power table values are corrupted and zones will not operate.
On FAGOR cooktops utilizing Innova high-frequency induction generator, ferromagnetic pan detection resonance, and rapid booster stages: Power line voltage surge corrupting non-volatile flash memory cells on touch microprocessor board.
Disconnect power circuit breaker for 15 minutes. Reconnect power and observe if calibration reloads; replace touch controller PCB if code persists. Clear and dry cooktop surface, disconnect mains power breaker for 60 seconds, reconnect and hold Key Padlock sensor for 5 seconds.
Fagor Masterchef / Innova / 6H Pyrolytic Multi-Function Oven: Child safety control lock active SAFE; display shows 'SAFE' and oven controls are locked against accidental activation.
On FAGOR ovens featuring Masterchef 6H pyrolytic thermal management, high-flow tangential cooling turbine, and digital programmer interface: User-activated child lock feature, or long accidental press on the Key pad or Clock icon.
Touch and hold the Key icon or Clock button firmly for 5 seconds until an audible beep confirms deactivation and 'SAFE' extinguishes. Return function selector to 0, isolate the power distribution breaker for 60 seconds, restore power and configure the clock.