Skip to content
CodesErreur.comSWISS PRO ENGINE
Core Diagnostics
DiagnosticsBrandsOEM ManualsSpecialistsAI EngineerPRO
Workshop Tools
Diagnostic ToolsNEW
Hardware interfaces & test probes
Find Rating Plate
Locate exact E-Nr, PNC & serial codes
Parts Locator
Global OEM spare parts suppliers
Community & Career
Academy & Courses
Masterclasses by senior technicians
Certification ExamsPRO
Verify your B2B technical credentials
Elite Forum
Peer-to-peer field troubleshooting
Tech Jobs
B2B recruitment & field opportunities
Leaderboard
Global ranking of verified specialists
Certified Appliance Engineering EcosystemApply for Certification →
Language Selector
Account & Access
Upgrade PRO
Back to Search
Bosch • Central Diagnostic Dictionary
247 Verified Codes in Database

Bosch Error Codes & Diagnostics

Access our premium database of error codes, common faults, and professional repair solutions for Bosch appliances.

Luxury front-loading washing machine in brushed titanium with illuminated dark glass drum
CodeAppliancesFault / DiagnosticsRepair InstructionsAction
F29
Washing Machine
Water Inlet Valve, Aquastop & Flowmeter

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: No water inflow detected F29; inlet valves energized but pressure sensor detects zero water accumulation.

On Bosch washers: Building main stopcock closed, kinked inlet hose, completely frozen fill...

Verify water tap is fully open and water flows freely into bucket. Ensure fill hose is...

Diagnose
F31
Washing Machine
Water Level Pressure Switch & Air Dome

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: Maximum safety water level exceeded F31; overflow protection trips, inlet valves closed and drain pump energized.

On Bosch washers: Mechanically jammed inlet solenoid valve seat, shorted inlet triac...

Shut off water tap. If water continues filling while unplugged, replace defective inlet...

Diagnose
F34
Washing Machine
Door Lock Mechanism & Safety Interlock

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: Door interlock failed to lock F34; solenoid pulse sent but lock mechanism fails to engage or confirm locked contact.

On Bosch washers: Jammed lock slider mechanism, broken bimetal / solenoid lock coil, bent...

Inspect door latch alignment and hinge tightness. Test door lock mechanism resistance...

Diagnose
F35
Washing Machine
Water Level Pressure Switch & Air Dome

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: Door interlock failed to unlock F35; door remains locked at cycle end, unlock pulse fails to release mechanism.

On Bosch washers: Mechanically jammed slider inside door latch, high tub water level...

Pull emergency manual door release strap inside bottom filter flap. Check for standing...

Diagnose
F36
Washing Machine
Heating Element, Thermostat & Safety Fuse

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: Door interlock sensing circuit fault F36; feedback line to microcontroller remains inconsistent with lock driver state.

On Bosch washers: Burnt SMD sense resistor on control board, high contact resistance on...

Disconnect mains power. Measure resistance across door interlock switch contacts. Inspect...

Diagnose
F37
Washing Machine
NTC Temperature Sensor & Thermistor

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: NTC sensor resistance open or high deviation F37; temperature value reads unrealistic cold (<-10°C) during wash.

On Bosch washers: Internal fracture in NTC ceramic bead, broken wire in lower wiring loom...

Measure NTC resistance directly at heater terminals (nominal ~10 kΩ at 20°C, ~4.9 kΩ at...

Diagnose
F38
Washing Machine
NTC Temperature Sensor & Thermistor

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: NTC temperature sensor short-circuit fault F38; sensor lines shorted together or to ground, reading > 120°C.

On Bosch washers: Melted wire insulation chafing against metal tub frame, internal...

Measure NTC resistance (must NOT be 0 Ω or < 500 Ω at room temperature). Inspect wiring for...

Diagnose
F42
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: Uncontrolled motor runaway speed error F42; drive motor revs instantly to maximum RPM without speed ramping control.

On Bosch washers: Shorted motor control triac on power module, defective optocoupler gate...

Inspect motor tail shaft to ensure tachometer magnet is firmly threaded. Test motor triac...

Diagnose
F43
Washing Machine
Heating Element, Thermostat & Safety Fuse

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: Motor stalled / drum rotation mechanically locked F43; drive motor energized but drum cannot rotate.

On Bosch washers: Foreign object (bra underwire, coin, sock) jammed between inner drum and...

Disconnect mains. Rotate drum by hand to check for stiffness. Remove heating element to...

Diagnose
F44
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: No bidirectional motor rotation F44; drum only turns in one direction during wash tumble, reversing relay stuck.

On Bosch washers: Welded contacts or defective coil on motor reversing relay on power...

Inspect motor reversing relays on control board. Measure coil resistance of both reversing...

Diagnose
F47
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: Motor inverter power module (IPM) overtemperature F47; thermal sensor on aluminum heatsink trips thermal shutdown.

On Bosch washers: Severe drum overload, high ambient temperature, dried thermal paste...

Allow inverter module to cool for 30 minutes. Reduce laundry load. Inspect aluminum...

Diagnose
F48
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: Inverter DC bus undervoltage detected F48; rectified high-voltage DC rail drops below minimum threshold (< 200V DC).

On Bosch washers: Severe AC mains voltage dip, degraded DC bus bulk electrolytic...

Check mains voltage at wall socket under load (> 207V AC). Measure DC bus voltage across...

Diagnose
F49
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: Inverter DC bus overvoltage detected F49; regenerated motor braking energy or AC mains surge exceeds safety limit (> 400V DC).

On Bosch washers: Heavy out-of-balance drum deceleration dumping excessive back-EMF, open...

Check mains line voltage. Measure braking dissipation circuit components on inverter board....

Diagnose
F50
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: 3-phase BLDC motor drive hardware fault F50; inverter bridge reports phase current imbalance or shorted IGBT.

On Bosch washers: Shorted phase winding in permanent magnet brushless motor, damaged motor...

Disconnect motor plug. Measure 3-phase winding resistances between U-V, V-W, U-W (must be...

Diagnose
F57
Washing Machine
Drive Motor, Inverter & Tachometer Sensor

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: Inverter serial D-Bus communication lost F57; main control module loses serial data link to motor inverter module.

On Bosch washers: Broken or disconnected communication wiring harness between upper and...

Inspect 3-wire communication harness linking main PCB to inverter module. Verify 230V AC...

Diagnose
F59
Washing Machine
General System & Mechanical Integration

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: 3D Hall acceleration sensor signal missing F59; tub motion sensor fails to report 3-axis vibration data during spin.

On Bosch washers: Loose or unplugged connector on 3D sensor mounted on outer tub, damaged...

Remove top lid. Inspect 3D sensor bolted to top edge of outer plastic tub. Verify 5V DC...

Diagnose
F60
Washing Machine
Water Level Pressure Switch & Air Dome

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: Flow sensor flow rate out of calibrated bounds F60; discrepancy between flowmeter pulse frequency and pressure rise.

On Bosch washers: Partially seized flow turbine wheel, partially blocked pressure switch...

Inspect inline flowmeter and clean turbine chamber. Clean pressure switch air trap and...

Diagnose
F61
Washing Machine
Door Lock Mechanism & Safety Interlock

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: Abnormal door lock feedback signal F61; door interlock reports unexpected state changes during high-speed rotation.

On Bosch washers: Loose door hinge causing strike hook vibration, pitting on internal...

Tighten door hinge mounting screws on front panel. Check harness plug fit on door...

Diagnose
F63
Washing Machine
Electronic Control Board (PCB) & Bus Communications

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: Functional safety processor watchdog trip F63; internal CPU self-test parity or RAM execution error detected on main PCB.

On Bosch washers: Electrostatic discharge (ESD), corrupted EEPROM memory registers,...

Power down machine at mains for 5 minutes. Inspect power module for ruptured electrolytic...

Diagnose
F67
Washing Machine
Electronic Control Board (PCB) & Bus Communications

Bosch Serie 4 / Serie 6 / Serie 8 / HomeProfessional EcoSilence Drive: Configuration variant coding error F67; EEPROM variant data mismatch between user interface and power module.

On Bosch washers: Unprogrammed replacement control board installed, corrupted model variant...

Access service mode to enter exact variant coding number from machine rating plate (E-Nr)....

Diagnose
FFFF
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Serial data bus communication fault between the cooktop control unit and the display module.

Interrupted or corrupted serial communication between the hob power board and the user...

Disconnect mains power, inspect the communication harness between the hob control unit and...

Diagnose
H
Dishwasher
General System & Mechanical Integration

After the flash fires, "H" appears on the display

Mains power was not reset after flashing. The device is in the factory test program.

1. Disconnect 230V mains power for 3 minutes. 2. Inspect wire harness and edge connectors...

Diagnose
rrr
Oven / Microwave
General System & Mechanical Integration

Bosch RRR: Operational cycle fault detected during Oven / Microwave program execution.

An operating mode was active during a power interruption

Switch off the device and reset the function

Diagnose
S
Oven / Microwave
General System & Mechanical Integration

Safety shutdown / Operating time limitation

Operating time limit reached for cooktops and oven

Allow to cool down, reset operation

Diagnose
U1
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Bosch Serie 6 / Serie 8 FlexInduction & PerfectFry Induction Cooktop: Severe connection wiring fault U1; 400V line-to-line voltage applied without neutral reference (missing neutral).

On Bosch hobs: Cooktop wired to 400V 3-phase supply with disconnected or loose blue neutral...

IMMEDIATELY switch off main breaker! Risk of PCB destruction. Verify terminal bridge...

Diagnose
U2
Hob / Cooktop
General System & Mechanical Integration

Bosch Serie 6 / Serie 8 FlexInduction & PerfectFry Induction Cooktop: Phase imbalance voltage anomaly U2; differential voltage between L1 and L2 lines exceeds 40V under active cooking load.

On Bosch hobs: Unequal line drop on undersized distribution cable, defective phase selector...

Measure voltage of L1-N and L2-N simultaneously with cooktop running at power level 9 on...

Diagnose
U3
Hob / Cooktop
Electronic Control Board (PCB) & Bus Communications

Bosch Serie 6 / Serie 8 FlexInduction & PerfectFry Induction Cooktop: DC bus voltage ripple excessive U3; rectified DC link voltage exhibits ripple voltage > 15% under induction load.

On Bosch hobs: Dried out DC bus smoothing filter capacitors (electrolyte leakage) or...

Disconnect power. Discharge DC bus. Check ESR of 400V DC filter capacitors on power board....

Diagnose
U400
Hob / Cooktop
General System & Mechanical Integration

U400 displayed statically, continuous loud signal

Incorrect connection of the cooktop to 400V instead of 230V, internal wiring error, or...

Immediately disconnect the cooktop from the mains, correct wiring. Ensure mains voltage...

Diagnose
00:00
Oven / Microwave
General System & Mechanical Integration

Digital clock display flashing 00:00; oven heating functions locked.

Mains power interruption or first electrical installation cleared electronic clock time memory.

Set digital clock time. Press Clock/Timer button, adjust current hour and minutes with...

Diagnose
1
Dishwasher
General System & Mechanical Integration

Error in the Aquasensor system (Error in Aquasensor system)

Displayed even if no sensor is present.

1. Disconnect 230V mains power for 3 minutes. 2. Inspect wire harness and edge connectors...

Diagnose
← Previous PagePage 8 of 9 (247 results)Next Page →

Bosch — Complete Error Code Catalog

210 Verified Error Codes

Server-side index of all verified manufacturer error codes for technicians and automated crawlers.

Dishwasher46

E01E02E03E04E05E06E07E08E09E10E11E12E13E14E15E16E17E18E19E20E21E22E23E24E25E26E27E28E29E30E31E3000E3100E3200E6101E6900E9001E9210H124816h:00 – h:24P0 Switchmirror 1

Washing Machine48

E34E35E37E38E42E43E44E47E48E49E50E57E59E60E61E67F16F17F18F19F20F21F22F23F25F26F27F28F29F31F34F35F36F37F38F42F43F44F47F48F49F50F57F59F60F61F63F67

Tumble Dryer16

E32E36E51E52E53E54E55E56E63E71E72E73E74E75E89E90

Oven / Microwave56

E000E005E009E010E011E101E104E106E107E115E136E137E138E139E140E141E142E143E144E244E300E303E305E309E310E312E344E395E396E397E398E399E516E845E5116Er 0Er 1Er1Er 2Er2Er 3Er 4Er4Er 5Er 6Er6Er 7Er 8Er8ER 9Er 11Er 15rrrS00:00000 (blinkend)

Hob / Cooktop43

d0d1d2d3d4d5d6d7d8d9EE0E1E2E3E4E5E6E7E8E9E0513E7015E8207EEEEEr13ErXYFF0F1F2F3F4F5F6F7F8F9FFFFU1U2U3U400

Refrigerator / Freezer1

AL

Need Help? Call a Certified Technician

Our official certified partners service Bosch appliances in your area.

Electroassistance (Switzerland)Appliance Care UK (United Kingdom)
CodesErreur.com

Premium appliance diagnostics & repair database.
Powered by AI to help certified technicians worldwide.

Trusted by professionals in CH & FR

Platform

Search DatabasePRO Diagnostic AIPRODiagnostic ToolsBrands

Workshop Tools

Brands (87)OEM ManualsFind Rating PlateParts Locator

For Technicians

SpecialistsTechnician ForumTech JobsPremium

Corporate

Terms of ServicePrivacy PolicyOfficial Swiss Repair Partner: Electroassistance
OPERATIONAL SAFETY SPECIFICATION

SAFETY DISCLAIMER

The technical information, diagnostic guides, error codes, and AI-generated suggestions provided on this website are intended exclusively for certified and qualified professionals. Appliance repair involves severe electrical hazards, high voltages, and mechanical risks that can result in fatal injury or severe property damage. If you are not a trained technician, do not attempt to repair any appliances. CodesErreur assumes no responsibility or liability for any damage, injury, or consequential losses resulting from the use of the information provided on this platform. You use all information entirely at your own risk.

© 2026 CodesErreur. All rights reserved.

Official Swiss Repair Partner: Electroassistance Terms of Service Privacy Policy